Precise Haptic Device Co-Location for Visuo-Haptic Augmented Reality

被引:22
作者
Eck, Ulrich [1 ]
Pankratz, Frieder [2 ]
Sandor, Christian [3 ]
Klinker, Gudrun [2 ]
Laga, Hamid [1 ]
机构
[1] Univ S Australia, Phen & Bioinformat Res Ctr, Adelaide, SA 5001, Australia
[2] Tech Univ Munich, Fachgebiet Augmented Real, D-80290 Munich, Germany
[3] Nara Inst Sci & Technol, Interact Media Design Lab, Nara, Japan
关键词
Calibration; orientation calibration; temporal alignment; COMPREHENSIVE WORKSPACE CALIBRATION;
D O I
10.1109/TVCG.2015.2480087
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Visuo-haptic augmented reality systems enable users to see and touch digital information that is embedded in the real world. PHANToM haptic devices are often employed to provide haptic feedback. Precise co-location of computer-generated graphics and the haptic stylus is necessary to provide a realistic user experience. Previous work has focused on calibration procedures that compensate the non-linear position error caused by inaccuracies in the joint angle sensors. In this article we present a more complete procedure that additionally compensates for errors in the gimbal sensors and improves position calibration. The proposed procedure further includes software-based temporal alignment of sensor data and a method for the estimation of a reference for position calibration, resulting in increased robustness against haptic device initialization and external tracker noise. We designed our procedure to require minimal user input to maximize usability. We conducted an extensive evaluation with two different PHANToMs, two different optical trackers, and a mechanical tracker. Compared to state-of-the-art calibration procedures, our approach significantly improves the co-location of the haptic stylus. This results in higher fidelity visual and haptic augmentations, which are crucial for fine-motor tasks in areas such as medical training simulators, assembly planning tools, or rapid prototyping applications.
引用
收藏
页码:1427 / 1441
页数:15
相关论文
共 25 条
[1]  
Bianchi Gerald., 2006, PROC EUROHAPTICS C, V6, P169
[2]  
Boggs P.T., 1990, CONTEMP MATH-SINGAP, V112, P183
[3]   Augmented versus virtual reality laparoscopic simulation: What is the difference? A comparison of the ProMIS augmented reality laparoscopic simulator versus LapSim virtual reality laparoscopic simulator [J].
Botden, Sanne M. B. I. ;
Buzink, Sonja N. ;
Schijven, Marlies P. ;
Jakimowicz, Jack J. .
WORLD JOURNAL OF SURGERY, 2007, 31 (04) :764-772
[4]   A critical study of the mechanical and electrical properties of the PHANToM haptic interface and improvements for high-performance control [J].
Çavusoglu, MC ;
Feygin, D ;
Tendick, F .
PRESENCE-TELEOPERATORS AND VIRTUAL ENVIRONMENTS, 2002, 11 (06) :555-568
[5]   Augmented Touch without Visual Obtrusion [J].
Cosco, Francesco I. ;
Garre, Carlos ;
Bruno, Fabio ;
Muzzupappa, Maurizio ;
Otaduy, Miguel A. .
2009 8TH IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY - SCIENCE AND TECHNOLOGY, 2009, :99-+
[6]  
Csongei M, 2012, INT SYM MIX AUGMENT, P277, DOI 10.1109/ISMAR.2012.6402572
[7]  
Eck U, 2014, INT SYM MIX AUGMENT, P333
[8]  
Eck U, 2014, INT SYM MIX AUGMENT, P123, DOI 10.1109/ISMAR.2014.6948417
[9]  
Fu MJ, 2011, IEEE INT C INT ROBOT, P3460, DOI 10.1109/IROS.2011.6048296
[10]   Calibration, Registration, and Synchronization for High Precision Augmented Reality Haptics [J].
Harders, Matthias ;
Bianchi, Gerald ;
Knoerlein, Benjamin ;
Szekely, Gabor .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2009, 15 (01) :138-149