Assessment of flow pattern of right ventricle outflow and pulmonary arteries in surgically corrected tetralogy of Fallot patients by four-dimensional cardiac magnetic resonance flow

被引:2
作者
Shaaban, Mahmoud [1 ]
Salama, Mai [1 ]
Alsaied, Ayman [1 ]
Elsheikh, Raghda [1 ]
Elmasry, Magdy [1 ]
机构
[1] Tanta Univ, Dept Cardiol, Fac Med, Tanta, Egypt
关键词
4D-CMR flow; 2D-PC flow; TOF; Pulmonary regurgitation; REPAIRED TETRALOGY; QUANTIFICATION; CIRCULATION; ADULTS;
D O I
10.1186/s43044-020-00092-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The most common post-surgical complication of tetralogy of Fallot (TOF) is pulmonary regurgitation (PR) which can lead to right ventricle (RV) dysfunction/failure. Cardiac magnetic resonance (CMR) is the imaging modality of choice to follow-up a repaired TOF. However, the conventional two-dimensional phase-contrast (2D-PC) flow usually underestimates PR as well as the pulmonary peak systolic velocity (PSV). Recently, four-dimensional (4D) CMR flow is introduced for more accurate quantitative flow assessment. This work aimed to compare between 4D-CMR and 2D-PC flow across the main (MPA), right (RPA), and left (LPA) pulmonary arteries (PAs) in surgically corrected TOF patients. Results: This study was conducted on 20 repaired TOF patients (range 3-9 years, 50% males). All patients had CMR exam on 1.5T scanner. 4D-CMR and 2D-PC flows were obtained at the proximal segments of the MPA, RPA, and LPA. The stroke volume index (SVI), regurgitation fraction (RF), and PSV measured by 4D-CMR were compared to 2D-PC flow. The SVI across the PAs was nearly similar between both methods (P = 0.179 for MPA, 0.218 for RPA, and 0.091 for LPA). However, the RF was significantly higher by 4D-CMR in comparison to 2D-PC flow (P = 0.027 for MPA, 0.039 for RPA, and 0.046 for LPA). The PSV as well was significantly higher by 4D-CMR flow (P = 0.003 for MPA, < 0.001 for RPA, and 0.002 for LPA). The Bland-Altman plots showed a good agreement between 4D-CMR and 2D-PC flow for the SVI, RF, and PSV across the pulmonary arteries. Conclusion: A good agreement existed between the two studied methods regarding pulmonary flow measurements. Because of its major advantage of performing a comprehensive flow assessment in a shorter time, 4D-CMR flow plays an important role in the assessment of patients with complex CHD especially in the pediatric group.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] Tetralogy of Fallot
    Apitz, Christian
    Webb, Gary D.
    Redington, Andrew N.
    [J]. LANCET, 2009, 374 (9699) : 1462 - 1471
  • [2] Caval Blood Flow Distribution in Patients with Fontan Circulation: Quantification by Using Particle Traces from 4D Flow MR Imaging
    Baechler, Pablo
    Valverde, Israel
    Pinochet, Natalia
    Nordmeyer, Sarah
    Kuehne, Titus
    Crelier, Gerard
    Tejos, Cristian
    Irarrazaval, Pablo
    Beerbaum, Philipp
    Uribe, Sergio
    [J]. RADIOLOGY, 2013, 267 (01) : 67 - 75
  • [3] Cloud-processed 4D CMR flow imaging for pulmonary flow quantification
    Chelu, Raluca G.
    Wanambiro, Kevin W.
    Hsiao, Albert
    Swart, Laurens E.
    Voogd, Teun
    van den Hoven, Allard T.
    van Kranenburg, Matthijs
    Coenen, Adriaan
    Boccalini, Sara
    Wielopolski, Piotr A.
    Vogel, Mika W.
    Krestin, Gabriel P.
    Vasanawala, Shreyas S.
    Budde, Ricardo P. J.
    Roos-Hesselink, Jolien W.
    Nieman, Koen
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1849 - 1856
  • [4] Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: Detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction
    Davlouros, PA
    Kilner, PJ
    Hornung, TS
    Li, W
    Francis, JM
    Moon, JCC
    Smith, GC
    Pennell, DJ
    Gatzoulis, MA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (11) : 2044 - 2052
  • [5] Frank G, 2020, ORTHODOX CHRISTIAN, P1
  • [6] 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography
    Gabbour, Maya
    Schnell, Susanne
    Jarvis, Kelly
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    [J]. PEDIATRIC RADIOLOGY, 2015, 45 (06) : 804 - 813
  • [7] Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteries
    Geiger, Julia
    Hirtler, Daniel
    Buerk, Jonas
    Stiller, Brigitte
    Arnold, Raoul
    Jung, Bernd
    Langer, Mathias
    Markl, Michael
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 200 - 208
  • [8] 4-D MRI flow analysis in the course of interrupted aortic arch reveals complex morphology and quantifies amount of collateral blood flow
    Hirtler, Daniel
    Geiger, Julia
    Jung, Bernd
    Markl, Michael
    Arnold, Raoul
    [J]. PEDIATRIC RADIOLOGY, 2013, 43 (08) : 1037 - 1040
  • [9] Repaired tetralogy of Fallot in the adult: monitoring and management
    Huehnergarth, Kier V.
    Gurvitz, Michelle
    Stout, Karen K.
    Otto, Catherine M.
    [J]. HEART, 2008, 94 (12) : 1663 - 1669
  • [10] Isorni M-A., 2018, ARCH CARDIOVAS DIS S, V10, P285