Seismic behavior evaluation of semi-rigid steel frames with EEP connections under the near-fault earthquakes

被引:0
|
作者
Najdian, Miaad [1 ]
Izadinia, Mohsen [2 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Bushehr Branch, Bushehr, Iran
[2] Islamic Azad Univ, Dept Civil Engn, Najaf Abad Branch, Esfahan, Iran
来源
ADVANCED BUILDING MATERIALS AND SUSTAINABLE ARCHITECTURE, PTS 1-4 | 2012年 / 174-177卷
关键词
EEP semi-rigid connections; near fault earthquakes; time history analysis; perform; 3D;
D O I
10.4028/www.scientific.net/AMM.174-177.561
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Pulse shape motions and huge amount of energy applied in short duration by the near fault earthquake, cause brittle fracture in welded connections, which is widely observed in Kobe 1995 and Northridge 1994 earthquakes. Rigid connections, which are generally welded due to lack of ductility, have low energy absorption capability. On the other hand, Semi-rigid connections have a ductile behavior and have a good ability to absorb energy. The purpose of this paper is analysis and compares the behaviors of "rigid" and "EEP semi-rigid" connections in cases of "four bolt extended", "eight bolt extended stiffened" and "eight bolt, four bolts wide, extended stiffened" under the near fault earthquakes with nonlinear time history analysis by perform 3D software. The results shown that the steel frame with "four bolt extended" semi-rigid connections have appropriate performance compared to the other frames.
引用
收藏
页码:561 / +
页数:2
相关论文
共 50 条
  • [21] Seismic Collapse Risk Assessment of Braced Frames under Near-Fault Earthquakes
    Sonwani, Jeet Kumar
    Jia, Gaofeng
    Mahmoud, Hussam N.
    Wang, Zhenqiang
    METALS, 2021, 11 (08)
  • [23] On the Seismic Evaluation of Steel Frames Laterally Braced with Perforated Steel Plate Shear Walls Considering Semi-Rigid Connections
    Majlesi, Arsalan
    Asadi-Ghoozhdi, Hamid
    Bamshad, Omid
    Attarnejad, Reza
    Masoodi, Amir R.
    Ghassemieh, Mehdi
    BUILDINGS, 2022, 12 (09)
  • [24] Buckling Analysis of Sway Steel Frames with Semi-rigid Connections
    Wang, Wanzhen
    Xu, Jixiang
    Chen, Feiyi
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3876 - +
  • [25] Reliability of semi-active seismic isolation under near-fault earthquakes
    Oncu-Davas, Seda
    Alhan, Cenk
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 114 (146-164) : 146 - 164
  • [26] Experimental research on semi-rigid beam-to-column connections in steel frames for seismic conditions
    Liu, S
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 572 - 576
  • [27] Effect of semi-rigid connections in improvement of seismic performance of steel moment-resisting frames
    Feizi, M. Gholipour
    Mojtahedi, A.
    Nourani, V.
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (02): : 467 - 484
  • [28] Effects of semi-rigid connections on reliability of steel frames under three-states
    Bai L.
    Jiang F.
    Wang Z.
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2016, 44 (01): : 27 - 30
  • [29] Performance of bolted semi-rigid connections under cyclic loading in steel portal frames
    Kim, YM
    Yang, CM
    SYSTEM-BASED VISION FOR STRATEGIC AND CREATIVE DESIGN, VOLS 1-3, 2003, : 899 - 905
  • [30] Evaluation of Steel Diagrid Structural System Under Near-Fault Earthquakes
    Saadati, Davood
    Javadi, Pasha
    Moghadam, A. S.
    Hosseini, Mir Hamid
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (08) : 2330 - 2360