Influence of the volume of soft tissue herniation on clinical symptoms of patients with orbital floor fractures

被引:31
|
作者
Safi, Ali-Farid [1 ]
Richter, Marie-Theres [1 ]
Rothamel, Daniel [1 ]
Nickenig, Hans-Joachim [1 ]
Scheer, Martin [2 ]
Zoeller, Joachim [1 ]
Kreppel, Matthias [1 ]
机构
[1] Univ Cologne, Dept Oral & Maxillofacial Plast Surg, Cologne, Germany
[2] Johannes Wesling Krankenhaus, Muhlenkreiskliniken Minden, Dept Oral & Maxillofacial Surg, Minden, Germany
关键词
Soft tissue herniation; Segmentation; Clinical symptoms; Orbital floor fractures; COMPUTED-TOMOGRAPHY; RECONSTRUCTION; GRAFT;
D O I
10.1016/j.jcms.2016.09.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: One of the most important complications of orbital floor fractures is diplopia and restricted ocular movement. The role of the volume of soft tissue herniation on these clinical symptoms after orbital floor fractures is unclear and potentially may predict development of persistent clinical symptoms. Therefore the aim of this study was to assess pre- and postoperative complications associated to the volume of soft tissue herniation, with special interest to diplopia and bulbus motility impairment. Material and methods: 204 untreated patients with orbital floor fractures from 2009 to 2011 were included in this retrospective study. Contingency tables and chi(2)-test were performed to analyze associations between two qualitative variables. p-Values p < 0.05 were considered as significant. Volume measurement was performed in a semiautomatic segmentation method with the software "ITK-Snap". Results: The volume of soft tissue herniation correlated significantly with pre- and postoperative diplopia (p = 0.003; p = 0.002), persistent diplopia (p = 0.009) as well as pre- and postoperative bulbus motility impairment (both p < 0.001). Furthermore we found out significant associations between the volume of soft tissue herniation and pre- and postoperative complications depending on fracture type and reconstruction technique. Conclusions: Volume measurement of soft tissue herniation may help to predict postoperative complications, particularly bulbus motility restriction and persistent diplopia. The risk for these symptoms rises with increasing volume of soft tissue herniation after orbital floor fractures. Therefore we recommend for these patients within indication an early repair and/or closer observation. (C) 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1929 / 1934
页数:6
相关论文
共 34 条
  • [1] Influence of Radiographic Soft Tissue Findings on Clinical Entrapment in Patients With Orbital Fractures
    Pontell, Matthew E.
    Jackson, Kianna
    Golinko, Michael
    Drolet, Brian C.
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (04) : 1427 - 1431
  • [2] Correlation between increased orbital volume and enophthalmos and diplopia in patients with fractures of the orbital floor or the medial orbital wall
    Schonegg, Daphne
    Wagner, Maximilian
    Schumann, Paul
    Essig, Harald
    Seifert, Burkhardt
    Rucker, Martin
    Gander, Thomas
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) : 1544 - 1549
  • [3] Mechanical resistance of the periorbita and the orbital floor complex-are isolated orbital floor fractures only a soft tissue problem?
    Birkenfeld, F.
    Behrens, E.
    Floerke, C.
    Rohnen, M.
    Wieker, H.
    Kern, M.
    Lucius, R.
    Wiltfang, J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (03) : 279 - 283
  • [4] Linear Computed Tomographic Measurement of Soft Tissue Herniation into the Maxillary Sinus as an Indicator for Orbital Floor Fracture Surgery: A Preliminary Study
    Tognin, Laura
    Bellinato, Micol
    Gazzani, Silvia Eleonora
    Pedrazzi, Giuseppe
    Poli, Tito
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2025, 24 (02) : 360 - 365
  • [5] Correlation Between Volume of Herniated Orbital Contents and the Amount of Enophthalmos in Orbital Floor and Wall Fractures
    Zhang, Zhiyong
    Zhang, Yi
    He, Yang
    An, Jinggang
    Zwahlen, Roger Arthur
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (01) : 68 - 73
  • [6] Clinical Criteria for Selective Exploration of Orbital Floor in Zygomaticomaxillary Complex Fractures
    Anehosur, Venkatesh
    Nathani, Jayesh
    Nagraj, Nikhil
    Nikhil, Krithi
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2020, 13 (03) : 180 - 185
  • [7] Correlation between Tomography Scan Findings and Clinical Presentation and Treatment Outcomes in Patients with Orbital Floor Fractures
    Stopa, Lukasz
    Stopa, Wojciech
    Stopa, Zygmunt
    DIAGNOSTICS, 2024, 14 (03)
  • [8] A comparable study of the diagnostic performance of orbital ultrasonography and CBCT in patients with suspected orbital floor fractures
    Johari, Masoumeh
    Ghavimi, Mohammad Ali
    Mahmoudian, Hediyeh
    Javadrashid, Reza
    Samani, Simin Mirakhor
    Fouladi, Daniel F.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
  • [9] Clinical application of 3D pre-bent titanium implants for orbital floor fractures
    Kozakiewicz, Marcin
    Elgalal, Marcin
    Loba, Piotr
    Komunski, Piotr
    Arkuszewski, Piotr
    Broniarczyk-Loba, Anna
    Stefanczyk, Ludomir
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2009, 37 (04) : 229 - 234
  • [10] Quantitative assessment of orbital fractures in Asian patients: CT measurement of orbital volume
    Sugiura, Kensuke
    Yamada, Harumoto
    Okumoto, Takayuki
    Inoue, Yoshikazu
    Onishi, Satoko
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (12) : 1944 - 1947