Measurement of Tension in a String Using an Array of Capacitive Force Sensors

被引:9
作者
Singal, Kalpesh [1 ,2 ]
Peng, Peng [1 ,2 ]
Rajamani, Rajesh [1 ,2 ]
Bechtold, Joan [1 ,2 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
Biomedical sensor; capacitive sensor; orthopedic surgery; tension measurement; STRAIN; LIGAMENTS; TENDON; PERFORMANCE; TRANSDUCER; WRIST;
D O I
10.1109/JSEN.2012.2226940
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurement of tension in strings and soft tissues is of critical importance in many applications, including orthopedic surgeries. Various sensors have previously been designed for the measurement of tension, but they all require either attachment of the sensor to the string or the use of an external-inertial reference. This paper presents two new sensors to estimate tension in strings without the need for attaching any devices on the string or a need for an inertial reference. Both sensors employ an array of three capacitive force measurement devices and estimate the tension based on these three readings. Experimental data show that the sensors can measure tension values up to 100 N on a bench-top test rig.
引用
收藏
页码:792 / 800
页数:9
相关论文
共 23 条
  • [1] Biomechanics of shoulder capsulorrhaphy procedures
    Ahmad, CS
    Wang, VM
    Sugalski, MT
    Levine, WN
    Bigliani, LU
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 12S - 18S
  • [2] ACL graft can replicate the normal ligament's tension curve
    Arnold, MP
    Verdonschot, N
    van Kampen, A
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (08) : 625 - 631
  • [3] DESIGN AND PERFORMANCE OF A MODIFIED BUCKLE TRANSDUCER FOR THE MEASUREMENT OF LIGAMENT TENSION
    BARRY, D
    AHMED, AM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (02): : 149 - 152
  • [4] Glenohumeral kinematics and capsule-ligamentous strain resulting from laxity exams
    Brenneke, SL
    Reid, J
    Ching, RP
    Wheeler, DL
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (10) : 735 - 742
  • [5] DYNAMIC PERFORMANCE-CHARACTERISTICS OF THE LIQUID-METAL STRAIN-GAUGE
    BROWN, TD
    SIGAL, L
    NJUS, GO
    NJUS, NM
    SINGERMAN, RJ
    BRAND, RA
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (02) : 165 - 173
  • [6] D'Lima D. D, 2011, CLIN ORTHOP RELAT R, V469, P1
  • [7] Dynamic Intraoperative ligament balancing for total knee arthroplasty
    D'Lima, Darryl D.
    Patil, Shantanu
    Steklov, Nikolai
    Colwell, Clifford W., Jr.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) : 208 - 212
  • [8] Influence of loading rate and cable migration on fiberoptic measurement of tendon force
    Erdemir, A
    Piazza, SJ
    Sharkey, NA
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (06) : 857 - 862
  • [9] DETERMINATION OF A ZERO STRAIN REFERENCE FOR THE ANTEROMEDIAL BAND OF THE ANTERIOR CRUCIATE LIGAMENT
    FLEMING, BC
    BEYNNON, BD
    TOHYAMA, H
    JOHNSON, RJ
    NICHOLS, CE
    RENSTROM, P
    POPE, MH
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) : 789 - 795
  • [10] In vivo measurement of ligament/tendon strains and forces:: A review
    Fleming, BC
    Beynnon, BD
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (03) : 318 - 328