Comparison of New and Established Full-Field Digital Mammography Systems in Diagnostic Performance

被引:3
作者
Ko, Eun Sook [1 ,2 ]
Han, Boo-Kyung [1 ,2 ]
Kim, Sun Mi [3 ]
Ko, Eun Young [1 ,2 ]
Jang, Mijung [3 ]
Lyou, Chae Yeon [3 ]
Chang, Jung Min [4 ]
Moon, Woo Kyung [4 ]
Kim, Rock Bum [5 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Songnam 463707, South Korea
[4] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[5] Dong A Univ, Sch Med, Dept Prevent Med, Pusan 602715, South Korea
关键词
Breast; Digital mammography; FFDM; Analysis; Comparison; SCREEN-FILM MAMMOGRAPHY; BREAST-CANCER; PROGRAM; DENSITY; TRIAL;
D O I
10.3348/kjr.2013.14.2.164
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the diagnostic performance of new and established full-field digital mammography (FFDM) systems. Materials and Methods: During a 15-month period, 1038 asymptomatic women who visited for mammography were prospectively included from two institutions. For women with routine two-view mammograms from established FFDM systems, bilateral mediolateral oblique (MLO) mammograms were repeated using the new FFDM system. One of the four reviewers evaluated two-sets of bilateral MLO mammograms at 4-week intervals by using a five-point score for the probability of malignancy according to a Breast Imaging Reporting and Data System. The lesion type and breast density were determined by the consensus of two readers at each institution. The dichotomized mammographic results correlated with a final pathologic outcome and follow-up data. Receiver operating characteristic (ROC) curves, sensitivity, and specificity were compared in general and according to the Lesion type and breast density. Results: Of the 1038 cases, 193 (18.6%) had cancer. The areas under the ROC curve (AUC), sensitivity, and specificity of the established system were 0.815, 65.3%, and 90.2%, respectively. Those of the new system were 0.839, 68.4%, and 91.7%, respectively. There were no significant differences in the AUCs, sensitivities or the specificities in general between new and established systems (Ps = 0.194, 0.590, 0.322, respectively). We found no significant difference in these parameters according to lesion type or breast density. Conclusion: The new FFDM system has a comparable diagnostic performance with established systems.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 21 条
[1]  
[Anonymous], 2003, BREAST IM REP DAT SY
[2]   Investigation of the effect of anode/filter materials on the dose and image quality of a digital mammography system based on an amorphous selenium flat panel detector [J].
Baldelli, P. ;
Phelan, N. ;
Egan, G. .
BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (988) :290-295
[3]   A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors [J].
Baldelli, P. ;
Phelan, N. ;
Egan, G. .
EUROPEAN RADIOLOGY, 2009, 19 (09) :2275-2285
[5]   Mammographic breast density and race [J].
del Carmen, Marcela G. ;
Halpern, Elkan F. ;
Kopans, Daniel B. ;
Moy, Beverly ;
Moore, Richard H. ;
Goss, Paul E. ;
Hughes, Kevin S. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) :1147-1150
[6]   Sample size calculation should be performed for design accuracy in diagnostic test studies [J].
Flahault, A ;
Cadilhac, M ;
Thomas, G .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (08) :859-862
[7]   Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening Trial [J].
Hendrick, R. Edward ;
Pisano, Etta D. ;
Averbukh, Alice ;
Moran, Catherine ;
Berns, Eric A. ;
Yaffe, Martin J. ;
Herman, Benjamin ;
Acharyya, Suddhasatta ;
Gatsonis, Constantine .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) :362-369
[8]   Breast Cancer Screening Results 5 Years after Introduction of Digital Mammography in a Population-based Screening Program [J].
Karssemeijer, Nico ;
Bluekens, Adriana M. ;
Beijerinck, David ;
Deurenberg, Jan J. ;
Beekman, Matthijs ;
Visser, Roelant ;
van Engen, Ruben ;
Bartels-Kortland, Annemieke ;
Broeders, Mireille J. .
RADIOLOGY, 2009, 253 (02) :353-358
[9]   Screen-film mammography and soft-copy full-field digital mammography: Comparison in the patients with microcalcifications [J].
Kim, HS ;
Han, BK ;
Choo, KS ;
Jeon, YH ;
Kim, JH ;
Choe, YH .
KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (04) :214-220
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .