Comparison of manual and computer-generated customized blocks for whole brain fields used in the treatment of medulloblastoma

被引:2
作者
Liu, M
Carrie, C
Parker, W
Freeman, CR
机构
[1] McGill Univ, Dept Radiat Oncol, Montreal, PQ H3A 2T5, Canada
[2] Ctr Leon Berard, Dept Radiotherapie, F-69373 Lyon, France
来源
MEDICAL AND PEDIATRIC ONCOLOGY | 2002年 / 38卷 / 01期
关键词
medulloblastoma; Cranio-spinal irradiation; CT simulation; radiation therapy;
D O I
10.1002/mpo.1265
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. By using CT simulation and three-dimensional planning, we have developed a simple but accurate method of producing customized blocks for the cranial fields in the treatment of medulloblastoma. We compare here the margins and the volume of normal tissues included in the treatment volume with those obtained using blocks generated manually. Procedure. Customized blocks for the whole brain field are generated using CT planning and autoblock function. The clinical target volume (CTV) is defined as the whole cerebrospinal fluid pathway, and the whole brain and spinal cord are contoured, A margin of 1.1 cm is generated using the autoblock-function to account for set-up errors (3-5 mm) and penumbra (approximately 7 mm). A separate set of blocks was generated manually without the knowledge of the ones generated by the CT-simulator. These 2 sets of blocks were compared for a cohort of 7 consecutive patients. Results. Overall, the manual blocks and the computer-generated blocks were quite similar. Those generated manually had more variations; they were always tighter (median of 6 mm tighter, range: 3-7 mm) at the level of the cribriform plate and in 5/7 patients were more generous (median of 6 mm more generous, range: 0-6 mm) at the temporal lobes. Dosimetric analysis showed that both methods provide adequate coverage of the CTV, with 100% of the CTV receiving >95% of the prescribed dose for both. Conclusions. The customized block method for whole brain fields is simple to use and ensures adequate coverage of the target volume. 0 2002 Wiley-Liss, Inc.
引用
收藏
页码:55 / 57
页数:3
相关论文
共 7 条
[1]   QUALITY-CONTROL OF RADIOTHERAPEUTIC TREATMENT OF MEDULLOBLASTOMA IN A MULTICENTRIC STUDY - THE CONTRIBUTION OF RADIOTHERAPY TECHNIQUE TO TUMOR RELAPSE [J].
CARRIE, C ;
ALAPETITE, C ;
MERE, P ;
AIMARD, L ;
PONS, A ;
KOLODIE, H ;
SENG, S ;
LAGRANGE, JL ;
PONTVERT, D ;
PIGNON, T ;
LACROZE, M ;
GINESTET, C ;
BERNARD, JL .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (02) :77-81
[2]   Impact of targeting deviations on outcome in medulloblastoma: Study of the French Society of Pediatric Oncology (SFOP) [J].
Carrie, C ;
Hoffstetter, S ;
Gomez, F ;
Moncho, V ;
Doz, F ;
Alapetite, C ;
Murraciole, X ;
Maire, JP ;
Benhassel, M ;
Chapet, S ;
Quetin, P ;
Kolodie, H ;
Lagrange, JL ;
Cuillere, JC ;
Habrand, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :435-439
[3]  
DONNAL J, 1992, AM J NEURORADIOL, V13, P1617
[4]   Postoperative radiationtherapy of medulloblastoma - Impact of radiation quality on treatment outcome [J].
Grabenbauer, GG ;
Beck, JD ;
Erhardt, J ;
Seegenschmiedt, MH ;
Seyer, H ;
Thierauf, P ;
Sauer, R .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1996, 19 (01) :73-77
[5]   Impact of radiation technique upon the outcome of treatment for medulloblastoma [J].
Halperin, EC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :233-239
[6]   Pediatric medulloblastoma: Radiation treatment technique and patterns of failure [J].
Miralbell, R ;
Bleher, A ;
Huguenin, P ;
Ries, G ;
Kann, R ;
Mirimanoff, RO ;
Notter, M ;
Nouet, P ;
Bieri, S ;
Thum, P ;
Toussi, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (03) :523-529
[7]   A NEWLY DESIGNED RADIATION PORT FOR MEDULLOBLASTOMA TO PREVENT METASTASIS TO THE CRIBRIFORM PLATE REGION [J].
UOZUMI, A ;
YAMAURA, A ;
MAKINO, H ;
MIYOSHI, T ;
ARIMIZU, N .
CHILDS NERVOUS SYSTEM, 1990, 6 (08) :451-455