Determination of 5-methyltetrahydrofolic acid in human serum by stable-isotope dilution high-performance liquid chromatography-mass spectrometry

被引:41
作者
Pawlosky, RJ
Flanagan, VP
Pfeiffer, CM
机构
[1] USDA ARS, Beltsville Agr Res Ctr, Beltsville Human Nutr Res Ctr, Food Composit Lab, Beltsville, MD 20705 USA
[2] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Environm Hlth Lab Sci, Atlanta, GA 30333 USA
基金
美国国家卫生研究院;
关键词
5-methyltetrahydrofolic acid; folate; electrospray mass spectrometry; human serum; isotope dilution;
D O I
10.1006/abio.2001.5394
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The need for specific and sensitive methods for the determination of distinct serum folates is of high priority in clinical research settings. A stable-isotope liquid chromatography-mass spectrometry (LC/ESI-MS) assay was developed for the quantitative determination of the monoglutamyl form of 5-methyltetrahydrofolic acid (5-MTHFA) in human serum. Serum samples (0.5 ml) were amended with the internal standard, [5-C-13(5)]MTHFA that had been labeled on the glutamic acid portion of the molecule and allowed to equilibrate. The analyte was trapped onto a solid-phase cartridge and then eluted with the HPLC mobile phase. Forty microliters was taken for LC/ESI-MS analysis using electrospray ionization operated in the positive ion mode. Using the standard method of addition of 5-MTHFA to serum, a linear dilution curve (y = 12.777x - 1.404; range 0.94-97 ng ml(-1)) was constructed. The precision of the method was 5.3% (CV) based on the analysis of four sample replicates. The mass spectrum produced upon collision induced dissociation of the analyte in serum was used to confirm the identity of the 5-MTHFA. The method was applied to the analysis of a set of serum samples that contained standardized concentrations of 5-MTHFA. The determinations of 5-MTHFA in these samples using the LC/ESI-MS procedure were found to be in good agreement with other folate methods. A highly accurate and specific method for the analysis of 5-MTHFA in serum has been developed utilizing stable isotope dilution mass spectrometry. (C) 2001 Academic Press.
引用
收藏
页码:299 / 305
页数:7
相关论文
共 50 条
  • [31] Determination of Residues of 5-Nitroimidazoles and Their Metabolites in Eggs by Isotope Dilution-Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Qiu X.
    Wang D.
    Li J.
    Xu Q.
    Wang M.
    Guan Z.
    Lu Y.
    Tu F.
    Shipin Kexue/Food Science, 2023, 44 (22): : 366 - 372
  • [32] Simultaneous Determination of 19 Plant Growth Regulator Residues in Plant-originated Foods by QuEChERS and Stable Isotope Dilution-Ultra Performance Liquid Chromatography-Mass Spectrometry
    Liu, Sijie
    Wu, Yongning
    Fang, Chiguang
    Cui, Yong
    Jiang, Nan
    Wang, Hui
    ANALYTICAL SCIENCES, 2017, 33 (09) : 1047 - 1052
  • [33] Simultaneous Determination of 19 Plant Growth Regulator Residues in Plant-originated Foods by QuEChERS and Stable Isotope Dilution-Ultra Performance Liquid Chromatography-Mass Spectrometry
    Sijie Liu
    Yongning Wu
    Chiguang Fang
    Yong Cui
    Nan Jiang
    Hui Wang
    Analytical Sciences, 2017, 33 : 1047 - 1052
  • [34] Determination of soyasaponins Ba and Bb in human serum by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Jin, Micong
    Yang, Yiwen
    Su, Baogen
    Ren, Qilong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 169 - 175
  • [35] Analysis of hexabromocyclododecane diastereoisomers in foods of animal origin using ultra performance liquid chromatography-mass spectrometry and isotope dilution
    Shi Zhixiong
    Feng Jinfang
    Li Jingguang
    Zhao Yunfeng
    Wu Yongning
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (01) : 1 - 5
  • [36] Isotope Dilution High-Performance Liquid Chromatography–Tandem Mass Spectrometry Method for Quantifying Urinary Metabolites of Synthetic Pyrethroid Insecticides
    Samuel E. Baker
    Anders O. Olsson
    Dana B. Barr
    Archives of Environmental Contamination and Toxicology, 2004, 46 : 281 - 288
  • [37] Determination of Hexabromocyclododecane in Textiles by Isotope Dilution-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Ma Qiang
    Bai Hua
    Wang Chao
    Xi Hai-Wei
    Ma Wei
    Zhou Xin
    Dong Yi-Yang
    Wang Bao-Lin
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2010, 31 (03): : 473 - 478
  • [38] Determination of linezolid in human serum and urine by high-performance liquid chromatography
    Borner, K
    Borner, E
    Lode, H
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2001, 18 (03) : 253 - 258
  • [39] Simultaneous glycosylation analysis of human serum glycoproteins by high-performance liquid chromatography/tandem mass spectrometry
    Harazono, Akira
    Kawasaki, Nana
    Itoh, Satsuki
    Hashii, Noritaka
    Matsuishi-Nakajima, Yukari
    Kawanishi, Toru
    Yamaguchi, Teruhide
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 869 (1-2): : 20 - 30
  • [40] Determination of sulbactam in raw bovine milk by isotope dilution-ultra-high-performance liquid chromatography-tandem mass spectrometry
    Li, P.
    Zhang, Y. D.
    Li, S. L.
    Wen, F.
    Li, H. Y.
    Zhao, S. G.
    Zheng, N.
    Wang, J. Q.
    JOURNAL OF DAIRY SCIENCE, 2019, 102 (11) : 9605 - 9610