Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study

被引:26
作者
An, Youngju [1 ]
Kang, Eun-Kyoung [2 ]
Kim, Hyojin [3 ,4 ]
Kang, Min-Ji [5 ]
Byun, Yong-Soo [5 ]
Joo, Choun-Ki [1 ,5 ]
机构
[1] Catholic Univ Korea, Coll Med, Catholic Inst Visual Sci, Seoul, South Korea
[2] Inha Univ, Dept Phys, Thin Film Opt Lab, Incheon, South Korea
[3] Baekseok Univ, Div Hlth Sci, Dept Visual Opt, Cheonan, South Korea
[4] Baekseok Univ, Grad Sch Hlth & Welf, Cheonan, South Korea
[5] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Coll Med, 505 Banpo Dong, Seoul 137040, South Korea
基金
新加坡国家研究基金会;
关键词
Intraocular lens power calculation; Cataract; Swept-source optical coherence tomography; Partial coherence interferometry; ULTRASOUND BIOMETRY; CATARACT; INTERFEROMETRY; REPRODUCIBILITY; PERFORMANCE; IMPACT;
D O I
10.1186/s12886-019-1036-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo evaluate the accuracy of biometric measurements by a swept-source optical coherence tomography (SS-OCT) based biometry for intraocular lens (IOL) power calculation.MethodsThis retrospective observational study enrolled 431 patients undergoing cataract surgery. The charts were reviewed to investigate the failure rate of axial length (AL) measurement of the SS-OCT biometer, partial coherence interferometry (PCI), and A-scan ultrasonography (US) according to cataract type and severity. AL and keratometry in 164 eyes with the same IOL inserted were measured using the SS-OCT biometer, PCI, and A-scan US. The SRK/T formula was used to calculate IOL power. The mean absolute error (MAE) and percentage of eyes with a prediction error (PE) of 0.50 D were compared.ResultsThe AL measurement failure rate was 0.00% for A-scan US, 2.32% for the SS-OCT biometer, and 15.31% for PCI. The number of eyes measured using three devices (SS-OCT biometer, PCI, and A-scan US) was 128 (Group A) and the number of eyes measured using two devices (SS-OCT biometer and A-scan US) was 36 (Group B). The score of posterior subcapsular opacity was significantly different between two groups (p<.001). The SS-OCT biometer and PCI showed significantly lower MAE compared to A-scan US in Group A (p=0.027). Using SS-OCT biometer, MAE showed no significant difference between Group A (0.360.27) and Group B (0.36 +/- 0.31) (p=0.785). Whereas, MAE of A-scan US was significantly higher than Group A (0.47 +/- 0.39) in Group B (0.64 +/- 0.36) (p=0.023).Conclusions Using biometry with advanced OCT is useful in clinical practice as it is more effective in obtaining biometric measurements in the eyes with PSC and provides accurate measurements for IOL power calculation regardless of cataract type and severity.Trial registration Retrospectively registered. Registration number: KC16RISI1020. Registered 03 January 2018.
引用
收藏
页数:7
相关论文
共 23 条
[1]   THE MORPHOLOGY OF CATARACT AND VISUAL PERFORMANCE [J].
BROWN, NAP .
EYE, 1993, 7 :63-67
[2]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[3]   Accuracy and reproducibility of biometry using partial coherence interferometry [J].
Connors, R ;
Boseman, P ;
Olson, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :235-238
[4]   Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery [J].
Findl, O ;
Kriechbaum, K ;
Sacu, S ;
Kiss, B ;
Polak, K ;
Nepp, J ;
Schild, G ;
Rainer, G ;
Maca, S ;
Petternel, V ;
Lackner, B ;
Drexler, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10) :1950-1955
[5]   The impact of cataract severity on measurement acquisition with the IOLMaster [J].
Freeman, G ;
Pesudovs, K .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (04) :439-442
[6]   Benchmark standards for refractive outcomes after NHS cataract surgery [J].
Gale, R. P. ;
Saldana, M. ;
Johnston, R. L. ;
Zuberbuhler, B. ;
McKibbin, M. .
EYE, 2009, 23 (01) :149-152
[7]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[8]   Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry [J].
Hoffer, Kenneth J. ;
Hoffmann, Peter C. ;
Savini, Giacomo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1165-1172
[9]   Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster [J].
Huang, Jinhai ;
Savini, Giacomo ;
Hoffer, Kenneth J. ;
Chen, Hao ;
Lu, Weicong ;
Hu, Qingjie ;
Bao, Fangjun ;
Wang, Qinmei .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) :493-498
[10]   The Effect of Cycloplegia on the Lenstar and the IOLMaster Biometry [J].
Huang, Jinhai ;
McAlinden, Colm ;
Su, Binbin ;
Pesudovs, Konrad ;
Feng, Yifan ;
Hua, Yanjun ;
Yang, Feng ;
Pan, Chao ;
Zhou, Huyong ;
Wang, Qinmei .
OPTOMETRY AND VISION SCIENCE, 2012, 89 (12) :1691-1696