Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion

被引:9
作者
He, Xiang [1 ]
Wengler, Kenneth [2 ]
Schweitzer, Mark E. [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
关键词
3D-GRASE; arterial spin labeling; diffusion sensitivity; pseudodiffusion; CEREBRAL-BLOOD-FLOW; INTRAVOXEL INCOHERENT MOTION; POSITRON-EMISSION-TOMOGRAPHY; WATER EXCHANGE; HUMAN BRAIN; IMAGING TECHNIQUES; 3D GRASE; MRI; MODEL; ECHO;
D O I
10.1002/mrm.27058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. TheoryThe extended phase graph (EPG) algorithm, originally designed to model the effects of T-1/T-2 relaxation and true diffusion in MRI acquisitions utilizing multiple refocusing RF pulses, was augmented (aEPG). This augmentation accounted for flow-related pseudodiffusion attenuation of intravascular MRI signal in the k-space domain during 3D-GRASE acquisition, which leads to blur along the partition direction in the image domain. Blurring of ASL signal into neighboring voxels can lead to underestimation of CBF in small, high-flow structures such as cortical gray matter (GM). MethodsThe diffusion sensitivity of 3D-GRASE was evaluated through aEPG simulations and in vivo experiments in 13 healthy subjects. The CBF estimation bias for different postlabeling delays, crusher gradient strengths, and segmentation factors along the partition (PAR) and phase-encoding (PE) directions was numerically assessed by simulations and experimentally validated. ResultsIn vivo experiments demonstrated systematic underestimation of mean GM CBF measured with segmented 3D-GRASE. The GM CBF underestimation depended on ASL preparation and imaging parameters; it reached up to 25% at low-segmentation schemes (1(PAR)x2(PE)) but was considerably lower at high-segmentation schemes (4(PAR)x2(PE) or 8(PAR)x2(PE)). Theoretical predictions showed that conventional T-1/T-2 relaxation and true diffusion may account for at most approximate to 25% of GM CBF estimation bias, whereas the pseudodiffusion effect constituted the major fraction in a typical ASL experiment. ConclusionThe pseudodiffusion effect leads to considerable estimation bias in ASL-based CBF quantification using 3D-GRASE readouts. This bias can be substantially reduced by increasing the segmentation factors. Magn Reson Med 80:736-747, 2018. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
引用
收藏
页码:736 / 747
页数:12
相关论文
共 65 条
  • [1] Perfusion fMRI for functional neuroimaging
    Aguirre, GK
    Detre, JA
    Wang, JJ
    [J]. NEUROIMAGING, PT A, 2005, 66 : 213 - 236
  • [2] Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia
    Alsop, David C.
    Detre, John A.
    Golay, Xavier
    Guenther, Matthias
    Hendrikse, Jeroen
    Hernandez-Garcia, Luis
    Lu, Hanzhang
    MacIntosh, Bradley J.
    Parkes, Laura M.
    Smits, Marion
    van Osch, Matthias J. P.
    Wang, Danny J. J.
    Wong, Eric C.
    Zaharchuk, Greg
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 102 - 116
  • [3] Alsop DC, 2000, ANN NEUROL, V47, P93, DOI 10.1002/1531-8249(200001)47:1<93::AID-ANA15>3.0.CO
  • [4] 2-8
  • [5] Regression Algorithm Correcting for Partial Volume Effects in Arterial Spin Labeling MRI
    Asllani, Iris
    Borogovac, Ajna
    Brown, Truman R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1362 - 1371
  • [6] MEASUREMENT OF HUMAN CEREBRAL BLOOD-FLOW WITH [O-15]BUTANOL AND POSITRON EMISSION TOMOGRAPHY
    BERRIDGE, MS
    ADLER, LP
    NELSON, AD
    CASSIDY, EH
    MUZIC, RF
    BEDNARCZYK, EM
    MIRALDI, F
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (05) : 707 - 715
  • [7] A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    Buxton, RB
    Frank, LR
    Wong, EC
    Siewert, B
    Warach, S
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 383 - 396
  • [8] Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields
    Dai, Weiying
    Garcia, Dairon
    de Bazelaire, Cedric
    Alsop, David C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1488 - 1497
  • [9] Aging-related differences in cerebral capillary blood flow in anesthetized rats
    Desjardins, Michele
    Berti, Romain
    Lefebvre, Joel
    Dubeau, Simon
    Lesage, Frederic
    [J]. NEUROBIOLOGY OF AGING, 2014, 35 (08) : 1947 - 1955
  • [10] PERFUSION IMAGING
    DETRE, JA
    LEIGH, JS
    WILLIAMS, DS
    KORETSKY, AP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 37 - 45