Design and application of occupant voting systems for collecting occupant feedback on indoor environmental quality of buildings - A review

被引:25
|
作者
Khan, Donya Sheikh [1 ,2 ]
Kolarik, Jakub [1 ]
Weitzmann, Peter [2 ]
机构
[1] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
[2] NCC Denmark, Soborg, Denmark
关键词
Occupant voting system; Occupant feedback; Indoor environmental quality; Post-occupancy evaluation; Occupant-centric control; Human in the loop; THERMAL COMFORT; IMPROVED EFFICIENCY; OFFICE ENVIRONMENT; HVAC OPERATIONS; BEHAVIOR; MODEL; EXPECTATION; CONSUMPTION; SIMULATION; EXPERIENCE;
D O I
10.1016/j.buildenv.2020.107192
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tools leveraging information and communication technologies for collecting occupant feedback on indoor environmental quality in buildings are receiving increasing attention. The obvious application examples of these tools, denoted as occupant voting system (OVS), include data-driven comfort models for control of buildings. Even though their application range is much wider, related literature is somewhat scattered across different building-related research fields. The aim of the present paper was to gather and review previous scientific publications about tools characterised as OVS across various applications, ranging from data-driven comfort models for control of building systems to occupant surveys for in-field research studies, as to characterise identified OVS. The present study applied Thematic Synthesis on fifty publications. This resulted in an explicit definition and framework to characterise OVS based on their application, design and used incentives motivating occupant interaction. The review revealed that OVS was applied to obtain thermal comfort models for temperature control, to support facility managers with building operation and to help occupants share their comfort votes with co-occupants. Moreover, OVS was used by researchers as a tool for collecting long-term in-field survey responses. The review also identified challenges related to occupants' interaction with OVS, occupants' interpretation of used assessment scales, occurrence of extreme votes, inconsistency in voting pattern and privacy concerns in relation to data collection and presentation of occupant votes.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Improving indoor air quality and occupant health through smart control of windows and portable air purifiers in residential buildings
    Wang, Yan
    Cooper, Elizabeth
    Tahmasebi, Farhang
    Taylor, Jonathon
    Stamp, Samuel
    Symonds, Phil
    Burman, Esfandiar
    Mumovic, Dejan
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2022, 43 (05): : 571 - 588
  • [32] The perceived quality of green buildings: from a review of occupant satisfaction towards a conceptual framework
    Halicioglu, Fahriye Hilal
    Gurel, Kubra
    INTERNATIONAL JOURNAL OF QUALITY & RELIABILITY MANAGEMENT, 2024, 41 (03) : 757 - 777
  • [33] Multimodal Data Fusion and Deep Learning for Occupant-Centric Indoor Environmental Quality Classification
    Lee, Min Jae
    Zhang, Ruichuan
    JOURNAL OF COMPUTING IN CIVIL ENGINEERING, 2025, 39 (02)
  • [34] A data-driven state-space model of indoor thermal sensation using occupant feedback for low-energy buildings
    Chen, Xiao
    Wang, Qian
    Srebric, Jelena
    ENERGY AND BUILDINGS, 2015, 91 : 187 - 198
  • [35] Assessment of indoor exposure to outdoor environmental noise and effects on occupant comfort in multi-unit residential buildings
    Andargie, Maedot S.
    Touchie, Marianne
    O'Brien, William
    Mueller-Trapet, Markus
    BUILDING ACOUSTICS, 2023, 30 (03) : 293 - 313
  • [36] A Systematic Review on the Use of AI for Energy Efficiency and Indoor Environmental Quality in Buildings
    Ogundiran, James
    Asadi, Ehsan
    da Silva, Manuel Gameiro
    SUSTAINABILITY, 2024, 16 (09)
  • [37] What did the occupant say? Fine-tuning and evaluating a large language model for efficient analysis of multi-domain indoor environmental quality feedback
    Sadick, Abdul-Manan
    Chinazzo, Giorgia
    BUILDING AND ENVIRONMENT, 2025, 274
  • [38] Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
    Al-Sabahi, Mohammed Hatim
    Ismail, Muhammad Azzam
    Alashwal, Ali Mohammed
    Al-Obaidi, Karam M.
    BUILDINGS, 2022, 12 (11)
  • [39] On a Post-occupancy Evaluation Study of Effects of Occupant Behavior on Indoor Environment Quality in College Buildings in Chongqing
    Yu, Xiaoping
    Liu, Liying
    Wu, Xu
    Wu, Xiaolin
    Wang, Zhimao
    Liu, Qing
    Shi, Guobing
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 623 - 627
  • [40] Occupant satisfaction with indoor environmental quality and health after energy retrofits of multi-family buildings: Results from INSULAtE-project
    Haverinen-Shaughnessy, Ulla
    Pekkonen, Maria
    Leivo, Virpi
    Prasauskas, Tadas
    Turunen, Mari
    Kiviste, Mihkel
    Aaltonen, Anu
    Martuzevicius, Dainius
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2018, 221 (06) : 921 - 928