Strain Measurement of Abdominal Aortic Aneurysm with Real-time 3D Ultrasound Speckle Tracking

被引:45
作者
Bihari, P. [1 ]
Shelke, A. [2 ]
Nwe, T. H. [3 ,4 ]
Mularczyk, M. [5 ,6 ]
Nelson, K. [1 ]
Schmandra, T. [1 ]
Knez, P. [1 ]
Schmitz-Rixen, T. [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Vasc & Endovasc Surg, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Inst Cell Biol & Neurosci, D-60590 Frankfurt, Germany
[3] Philipps Univ Marburg Lahn, Univ Med Ctr, Dept Cardiol, Marburg, Germany
[4] Philipps Univ Marburg Lahn, Univ Med Ctr, Dept Cardiac & Thorac Vasc Surg, Marburg, Germany
[5] Tech Univ Darmstadt, State Mat Testing Inst, Darmstadt, Germany
[6] Tech Univ Darmstadt, Inst Mat Sci, Darmstadt, Germany
关键词
Abdominal aortic aneurysm; Rupture; Three-dimensional imaging; Ultrasonography; Speckle tracking; Strain; MECHANICAL-PROPERTIES; RUPTURE RISK; WALL; DIAMETER; STRESS;
D O I
10.1016/j.ejvs.2013.01.004
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Materials and methods: Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Results: Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Conclusion: Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. (C) 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:315 / 323
页数:9
相关论文
共 24 条
[1]   A COMPLIANT TUBULAR DEVICE TO STUDY THE INFLUENCES OF WALL STRAIN AND FLUID SHEAR-STRESS ON CELLS OF THE VASCULAR WALL [J].
BENBRAHIM, A ;
LITALIEN, GJ ;
MILINAZZO, BB ;
WARNOCK, DF ;
DHARA, S ;
GERTLER, JP ;
ORKIN, RW ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (02) :184-194
[2]   Strain estimation in abdominal aortic aneurysms from 2-D ultrasound [J].
Brekken, R ;
Bang, J ;
Odegard, A ;
Aasland, J ;
Hernes, TAN ;
Myhre, HO .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (01) :33-42
[3]   Prediction of rupture risk in abdominal aortic aneurysm during observation: Wall stress versus diameter [J].
Fillinger, MF ;
Marra, SP ;
Raghavan, ML ;
Kennedy, FE .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (04) :724-732
[4]   NONCONTACT METHOD FOR 3-DIMENSIONAL ANALYSIS OF VASCULAR ELASTICITY INVIVO AND INVITRO [J].
FRONEK, K ;
SCHMIDSCHOENBEIN, G ;
FUNG, YC .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (04) :634-637
[5]   Echocardiographic Assessment of Myocardial Strain [J].
Gorcsan, John, III ;
Tanaka, Hidekazu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (14) :1401-1413
[6]   A tutorial on ultrasonic physics and imaging techniques [J].
Halliwell, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H2) :127-142
[7]   Real-time three-dimensional echocardiography - A novel technique to quantify global left ventricular mechanical dyssynchrony [J].
Kapetanakis, S ;
Kearney, MT ;
Siva, A ;
Gall, N ;
Cooklin, M ;
Monaghan, MJ .
CIRCULATION, 2005, 112 (07) :992-1000
[8]   Rotational in vitro compliance measurement of diverse anastomotic configurations: a tool for anastomotic engineering [J].
Knez, P ;
Nelson, K ;
Hakimi, M ;
Al-Haidary, J ;
Schneider, C ;
Schmitz-Rixen, T .
JOURNAL OF BIOMECHANICS, 2004, 37 (03) :275-280
[9]   DIAMETER AND COMPLIANCE IN THE MALE HUMAN ABDOMINAL-AORTA - INFLUENCE OF AGE AND AORTIC-ANEURYSM [J].
LANNE, T ;
SONESSON, B ;
BERGQVIST, D ;
BENGTSSON, H ;
GUSTAFSSON, D .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (02) :178-184
[10]   Immediate repair compared with surveillance of small abdominal aortic aneurysms. [J].
Lederle, FA ;
Wilson, SE ;
Johnson, GR ;
Reinke, DB ;
Littooy, FN ;
Acher, CW ;
Ballard, DJ ;
Messina, LM ;
Gordon, IL ;
Chute, EP ;
Krupski, WC ;
Bandyk, D .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (19) :1437-1444