Augmented Reality Visualization with Use of Image Overlay Technology for MR Imaging-guided Interventions: Assessment of Performance in Cadaveric Shoulder and Hip Arthrography at 1.5 T

被引:26
作者
Fritz, Jan [1 ]
U-Thainual, Paweena [2 ,3 ,4 ]
Ungi, Tamas [4 ]
Flammang, Aaron J. [5 ]
Fichtinger, Gabor [4 ]
Iordachita, Iulian I. [2 ,3 ]
Carrino, John A. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Lab Computat Sensing & Robot, Baltimore, MD 21287 USA
[4] Queens Univ, Sch Comp, Kingston, ON, Canada
[5] Siemens Corp Res, Ctr Appl Med Imaging, Baltimore, MD USA
基金
加拿大自然科学与工程研究理事会;
关键词
BIOPSY; MANIPULATOR; ACCURACY; GUIDANCE;
D O I
10.1148/radiol.12112640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively assess overlay technology in providing accurate and efficient targeting for magnetic resonance (MR) imaging-guided shoulder and hip joint arthrography. Materials and Methods: A prototype augmented reality image overlay system was used in conjunction with a clinical 1.5-T MR imager. A total of 24 shoulder joint and 24 hip joint injections were planned in 12 human cadavers. Two operators (A and B) participated, each performing procedures on different cadavers using image overlay guidance. MR imaging was used to confirm needle positions, monitor injections, and perform MR arthrography. Accuracy was assessed according to the rate of needle adjustment, target error, and whether the injection was intraarticular. Efficiency was assessed according to arthrography procedural time. Operator differences were assessed with comparison of accuracy and procedure times between the operators. Mann-Whitney U test and Fisher exact test were used to assess group differences. Results: Forty-five arthrography procedures (23 shoulders, 22 hips) were performed. Three joints had prostheses and were excluded. Operator A performed 12 shoulder and 12 hip injections. Operator B performed 11 shoulder and 10 hip injections. Needle adjustment rate was 13% (six of 45; one for operator A and five for operator B). Target error was 3.1 mm +/- 1.2 (standard deviation) (operator A, 2.9 mm +/- 1.4; operator B, 3.5 mm +/- 0.9). Intraarticular injection rate was 100% (45 of 45). The average arthrography time was 14 minutes (range, 6-27 minutes; 12 minutes [range, 6-25 minutes] for operator A and 16 minutes [range, 6-27 min] for operator B). Operator differences were not significant with regard to needle adjustment rate (P = .08), target error (P = .07), intraarticular injection rate (P > .99), and arthrography time (P = .22). Conclusion: Image overlay technology provides accurate and efficient MR guidance for successful shoulder and hip arthrography in human cadavers. (C) RSNA, 2012
引用
收藏
页码:254 / 259
页数:6
相关论文
共 25 条
[1]   Flexible Add-on Solution for MR Image-Guided Interventions in a Closed-Bore Scanner Environment [J].
Busse, Harald ;
Garnov, Nikita ;
Thoermer, Gregor ;
Zajonz, Dirk ;
Gruender, Wilfried ;
Kahn, Thomas ;
Moche, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) :922-928
[2]  
Cai ZJ, 1999, WHO TECH REP SER, V887, P1
[3]   Performance of interventions with manipulator-driven real-time MR guidance: implementation and initial in vitro tests [J].
Christoforou, Eftychios ;
Akbudak, Erbil ;
Ozcan, Alpay ;
Karanikolas, Menelaos ;
Tsekos, Nikolaos V. .
MAGNETIC RESONANCE IMAGING, 2007, 25 (01) :69-77
[4]   Arthrography of the shoulder:: A simple fluoroscopically guidedapproach for targeting the rotator cuff interval [J].
Dépelteau, H ;
Bureau, NJ ;
Cardinal, E ;
Aubin, B ;
Brassard, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (02) :329-332
[5]   Augmented Reality Visualization With Image Overlay for MRI-Guided Intervention: Accuracy for Lumbar Spinal Procedures With a 1.5-T MRI System [J].
Fritz, Jan ;
U-Thainual, Paweena ;
Ungi, Tamas ;
Flammang, Aaron J. ;
Cho, Nathan B. ;
Fichtinger, Gabor ;
Iordachita, Iulian I. ;
Carrino, John A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (03) :W266-W273
[6]   Freehand Real-Time MRI-Guided Lumbar Spinal Injection Procedures at 1.5 T: Feasibility, Accuracy, and Safety [J].
Fritz, Jan ;
Thomas, Christoph ;
Clasen, Stephan ;
Claussen, Claus D. ;
Lewin, Jonathan S. ;
Pereira, Phillipe L. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :W161-W167
[7]   MR-guided direct arthrography of the hip [J].
Graves, Martin J. ;
Wakely, Suzanne ;
Bearcroft, Philip W. ;
Black, Richard T. ;
van Rooyen, Elzare ;
Soh, Edmund ;
Lomas, David J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (02) :462-465
[8]   MRI-compatible manipulator with remote-center-of-motion control [J].
Hata, Nobuhiko ;
Tokuda, Junichi ;
Hurwitz, Shelley ;
Morikawa, Shigehiro .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (05) :1130-1138
[9]  
KILCOYNE RF, 1992, SKELETAL RADIOL, V21, P239
[10]   MR arthrography of the shoulder and hip after fluoroscopic landmarking [J].
Miller, TT .
SKELETAL RADIOLOGY, 2000, 29 (02) :81-84