PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence

被引:56
|
作者
Campbell, Peter G. [1 ]
Cavanaugh, David A. [1 ]
Nunley, Pierce [1 ]
Utter, Philip A. [1 ]
Kerr, Eubulus [1 ]
Wadhwa, Rishi [1 ]
Stone, Marcus [1 ]
机构
[1] Spine Inst Louisiana, Shreveport, LA 71101 USA
关键词
XLIF; LLIF; DLIF; direct; extreme; lateral lumbar interbody fusion; subsidence; PEEK; titanium; polyetheretherketone; comparative effectiveness; ANTERIOR CERVICAL DISKECTOMY; POLYETHERETHERKETONE; TI;
D O I
10.3171/2020.6.FOCUS20367
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE The authors have provided a review of radiographic subsidence after lateral lumbar interbody fusion (LLIF) as a comparative analysis between titanium and polyetheretherketone (PEEK) cages. Many authors describe a reluctance to use titanium cages in spinal fusion secondary to subsidence concerns due to the increased modulus of elasticity of metal cages. The authors intend for this report to provide observational data regarding the juxtaposition of these two materials in the LLIF domain. METHODS A retrospective review of a prospectively maintained database identified 113 consecutive patients undergoing lateral fusion for degenerative indications from January to December 2017. The surgeons performing the cage implantations were two orthopedic spine surgeons and two neurosurgeons. Plain standing radiographs were obtained at 1-2 weeks, 8-12 weeks, and 12 months postoperatively. Using a validated grading system, interbody subsidence into the endplates was graded at these time points on a scale of 0 to III. The primary outcome measure was subsidence between the two groups. Secondary outcomes were analyzed as well. RESULTS Of the 113 patients in the sample, groups receiving PEEK and titanium implants were closely matched at 57 and 56 patients, respectively. Cumulatively, 156 cages were inserted and recombinant human bone morphogenetic protein-2 (rhBMP-2) was used in 38.1%. The average patient age was 60.4 years and average follow- up was 75.1 weeks. Subsidence in the titanium group in this study was less common than in the PEEK cage group. At early follow-up, groups had similar subsidence outcomes. Statistical significance was reached at the 8- to 12-week and 52-week follow-ups, demonstrating more subsidence in the PEEK cage group than the titanium cage group. rhBMP-2 usage was also highly correlated with higher subsidence rates at all 3 follow-up time points. Age was correlated with higher subsidence rates in univariate and multivariate analysis. CONCLUSIONS Titanium cages were associated with lower subsidence rates than PEEK cages in this investigation. Usage of rhBMP-2 was also robustly associated with higher endplate subsidence. Each additional year of age correlated with an increased subsidence risk. Subsidence in LLIF is likely a response to a myriad of factors that include but are certainly not limited to cage material. Hence, the avoidance of titanium interbody implants secondary solely to concerns over a modulus of elasticity likely overlooks other variables of equal or greater importance.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] Utilization of Dual Expandable Cages in Lateral Lumbar Interbody Fusion Surgery
    Omosor, Emmanuel
    Edelbach, Brandon M.
    Amer, Hammad
    Hussain, Namath S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [42] PEEK versus titanium-coated PEEK cervical cages: fusion rate
    Godlewski, Bartosz
    Bebenek, Adam
    Dominiak, Maciej
    Karpinski, Grzegorz
    Cieslik, Piotr
    Pawelczyk, Tomasz
    ACTA NEUROCHIRURGICA, 2022, 164 (06) : 1501 - 1507
  • [43] Endplate Changes with Polyetheretherketone Cages in Posterior Lumbar Interbody Fusion
    Elfiky, Tarek Anwar
    Patil, Nirmal Dhananjay
    Allam, Yasser
    Ragab, Raafat
    ASIAN SPINE JOURNAL, 2020, 14 (02) : 229 - 237
  • [44] Graft subsidence as a predictor of revision surgery following stand-alone lateral lumbar interbody fusion
    Tempel, Zachary J.
    McDowell, Michael M.
    Panczykowski, David M.
    Gandhoke, Gurpreet S.
    Hamilton, D. Kojo
    Okonkwo, David O.
    Kanter, Adam S.
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (01) : 50 - 56
  • [45] Subsidence of Polyetheretherketone Cage After Minimally Invasive Transforaminal Lumbar Interbody Fusion
    Kim, Moon-Chan
    Chung, Hung-Tae
    Cho, Jae-Lim
    Kim, Dong-Jun
    Chung, Nam-Su
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (02): : 87 - 92
  • [46] Timing of Lateral Lumbar Interbody Subsidence: Review of Exclusive Intraoperative Subsidence
    Wewel, Joshua T.
    Hartman, Cory
    Uribe, Juan S.
    WORLD NEUROSURGERY, 2020, 137 : E208 - E212
  • [47] Fusion rate following extreme lateral lumbar interbody fusion
    Berjano, Pedro
    Langella, Francesco
    Damilano, Marco
    Pejrona, Matteo
    Buric, Josip
    Ismael, Maryem
    Villafane, Jorge Hugo
    Lamartina, Claudio
    EUROPEAN SPINE JOURNAL, 2015, 24 : S369 - S371
  • [48] Fusion rate following extreme lateral lumbar interbody fusion
    Pedro Berjano
    Francesco Langella
    Marco Damilano
    Matteo Pejrona
    Josip Buric
    Maryem Ismael
    Jorge Hugo Villafañe
    Claudio Lamartina
    European Spine Journal, 2015, 24 : 369 - 371
  • [49] Biomechanical Analysis of Porous Additive Manufactured Cages for Lateral Lumbar Interbody Fusion: A Finite Element Analysis
    Zhang, Zhenjun
    Li, Hui
    Fogel, Guy R.
    Liao, Zhenhua
    Li, Yang
    Liu, Weiqiang
    WORLD NEUROSURGERY, 2018, 111 : E581 - E591
  • [50] Lateral Lumbar Trans-Psoas Interbody Fusion
    Simpson, Andrew K.
    Harrod, Chambliss
    White, Andrew P.
    TECHNIQUES IN ORTHOPAEDICS, 2011, 26 (03) : 156 - 165