A comparative study of the electrochemical characteristics and simultaneous determination of dopamine, acetaminophen, and aspirin at a ruthenium oxide nanoparticles modified glassy carbon electrode versus a bare one

被引:12
作者
Chatraei, Fatemeh [1 ]
Zare, Hamid R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd 89195741, Iran
关键词
BATCH INJECTION-ANALYSIS; ASCORBIC-ACID; ACETYLSALICYLIC-ACID; PASTE ELECTRODE; ELECTROCATALYTIC OXIDATION; LIQUID-CHROMATOGRAPHY; AMPEROMETRIC DETERMINATION; HUMAN PLASMA; URIC-ACID; PARACETAMOL;
D O I
10.1039/c2ay25402f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the study of the electrochemical oxidation of dopamine (DA), acetaminophen (AC), and aspirin (ASA) comparatively conducted at a ruthenium oxide nanoparticles modified glassy carbon electrode (RuON-GCE) and at a bare glassy carbon electrode (BGCE). The obtained results show that the reversibility of DA, AC and ASA is significantly improved on RuON-GCE in comparison with BGCE. Using differential pulse voltammetry, the prepared sensor showed good sensitivity and selectivity for the individual and the simultaneous determination of DA, AC and ASA. The effect of the modification of the electrode surface on the diffusion coefficient, D, of DA, AC, and ASA in solution as well as the heterogeneous electron transfer rate constant, k', between the three species and both electrode (BGCE and RuON-GCE) surfaces are studied. The results indicate that the D values of the three species are independent but their k' values are dependent on the nature of the electrode surface.
引用
收藏
页码:2940 / 2947
页数:8
相关论文
共 66 条
[1]   A validated HPLC method for the determination of pyridostigmine bromide, acetaminophen, acetylsalicylic acid and caffeine in rat plasma and urine [J].
Abu-Qare, AW ;
Abou-Donia, MB .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (5-6) :939-947
[2]   Electrocatalytic detection of dopamine at single-walled carbon nanotubes-iron (III) oxide nanoparticles platform [J].
Adekunle, Abolanle S. ;
Agboola, Bolade O. ;
Pillay, Jeseelan ;
Ozoemena, Kenneth I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01) :93-102
[3]  
Akay C, 2008, TURK J MED SCI, V38, P167
[4]   FT-IR and Raman spectroscopic methods for identification and quantitation of orthorhombic and monoclinic paracetamol in powder mixes [J].
Al-Zoubi, N ;
Koundourellis, JE ;
Malamataris, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (03) :459-467
[5]   Simultaneous electrochemical determination of dopamine and acetaminophen using multiwall carbon nanotubes modified glassy carbon electrode [J].
Alothman, Zeid Abdullah ;
Bukhari, Nausheen ;
Wabaidur, Saikh Mohammad ;
Haider, Sajjad .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :314-320
[6]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[7]  
Behpour M, 2010, INT J ELECTROCHEM SC, V5, P1922
[8]   Determination of paracetamol:: Historical evolution [J].
Bosch, M. Espinosa ;
Sanchez, A. J. Ruiz ;
Rojas, F. Sanchez ;
Ojeda, C. Bosch .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (03) :291-321
[9]   Simultaneous stereoselective analysis of tramadol and its primary phase I metabolites in plasma by liquid chromatography -: Application to a pharmacokinetic study in humans [J].
Campanero, MA ;
García-Quetglas, E ;
Sádaba, B ;
Azanza, JR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1031 (1-2) :219-228
[10]   Electrodeposited acetaminophen as a bifunctional electrocatalyst for simultaneous determination of ascorbic acid, glutathione, adrenaline and tryptophan [J].
Chatraei, Fatemeh ;
Zare, Hamid R. .
ANALYST, 2011, 136 (21) :4595-4602