Dual-energy CT of the abdomen

被引:70
作者
Morgan, Desiree E. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA
来源
ABDOMINAL IMAGING | 2014年 / 39卷 / 01期
基金
美国国家卫生研究院;
关键词
Dual-energy CT; Abdomen; Dual-source; Rapid-switching; Single-source; Virtual unenhanced; COMPUTED-TOMOGRAPHY; URIC-ACID; IODINE QUANTIFICATION; ATTENUATION VALUES; CONTRAST MATERIAL; MULTIDETECTOR CT; URINARY STONES; IMAGE-QUALITY; RENAL MASSES; SPECTRAL CT;
D O I
10.1007/s00261-013-0033-5
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Although conceived of in the 1970s, practical use of dual-energy CT in the clinical setting did not come to fruition until 2006, and since that time an ever expanding exploration of the technology has been underway. This article will discuss technical aspects of the two commercially available CT scanners, review the recent literature, and provide an organ-based description of abdominal dual-energy CT applications for the practicing radiologist.
引用
收藏
页码:108 / 134
页数:27
相关论文
共 60 条
[1]   Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity [J].
Altenbernd, Jens ;
Heusner, Till A. ;
Ringelstein, Adrian ;
Ladd, Susanne C. ;
Forsting, Michael ;
Antoch, Gerald .
EUROPEAN RADIOLOGY, 2011, 21 (04) :738-743
[2]   Contrast-Enhanced Dual-Energy CT of Gastrointestinal Stromal Tumors Is Iodine-Related Attenuation a Potential Indicator of Tumor Response? [J].
Apfaltrer, Paul ;
Meyer, Mathias ;
Meier, Caroline ;
Henzler, Thomas ;
Barraza, John M., Jr. ;
Dinter, Dietmar J. ;
Hohenberger, Peter ;
Schoepf, U. Joseph ;
Schoenberg, Stefan O. ;
Fink, Christian .
INVESTIGATIVE RADIOLOGY, 2012, 47 (01) :65-70
[3]   Quantification of Hepatic Steatosis With Dual-Energy Computed Tomography Comparison With Tissue Reference Standards and Quantitative Magnetic Resonance Imaging in the ob/ob Mouse [J].
Artz, Nathan S. ;
Hines, Catherine D. G. ;
Brunner, Stephen T. ;
Agni, Rashmi M. ;
Kuehn, Jens-Peter ;
Roldan-Alzate, Alejandro ;
Chen, Guang-Hong ;
Reeder, Scott B. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (10) :603-610
[4]   Single-phase dual-energy CT urography in the evaluation of haematuria [J].
Ascenti, G. ;
Mileto, A. ;
Gaeta, M. ;
Blandino, A. ;
Mazziotti, S. ;
Scribano, E. .
CLINICAL RADIOLOGY, 2013, 68 (02) :E87-E94
[5]   Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements [J].
Ascenti, Giorgio ;
Mileto, Achille ;
Krauss, Bernhard ;
Gaeta, Michele ;
Blandino, Alfredo ;
Scribano, Emanuele ;
Settineri, Nicola ;
Mazziotti, Silvio .
EUROPEAN RADIOLOGY, 2013, 23 (08) :2288-2295
[6]  
Blake MA, 2011, RADIOGRAPHICS, V31, P1047, DOI 10.1148/rg.314105159
[7]   The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping [J].
Boellaard, T. N. ;
Henneman, O. D. F. ;
Streekstra, G. J. ;
Venema, H. W. ;
Nio, C. Y. ;
van Dorth-Rombouts, M. C. ;
Stoker, J. .
CLINICAL RADIOLOGY, 2013, 68 (08) :799-806
[8]   Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses [J].
Chandarana, Hersh ;
Megibow, Alec J. ;
Cohen, Benjamin A. ;
Srinivasan, Ramya ;
Kim, Danny ;
Leidecker, Christianne ;
Macari, Michael .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W693-W700
[9]   Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours [J].
Chu, A. J. ;
Lee, J. M. ;
Lee, Y. J. ;
Moon, S. K. ;
Han, J. K. ;
Choi, B. I. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) :E891-E898
[10]   Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images [J].
De Cecco, Carlo Nicola ;
Buffa, Vitaliano ;
Fedeli, Stefano ;
Luzietti, Monica ;
Vallone, Andrea ;
Ruopoli, Roberto ;
Miele, Vittorio ;
Rengo, Marco ;
Paolantonio, Pasquale ;
Enrici, Michelangelo Maurizi ;
Laghi, Andrea ;
David, Vincenzo .
EUROPEAN RADIOLOGY, 2010, 20 (12) :2870-2875