Simultaneous estimation of PD, T1, T2, T2*, and ΔB0 using magnetic resonance fingerprinting with background gradient compensation

被引:15
|
作者
Hong, Taehwa [1 ]
Han, Dongyeob [1 ]
Kim, Dong-Hyun [1 ]
机构
[1] Yonsei Univ, Dept Elect & Elect Engn, Engn Hall 3,Room C228, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
background field compensation; MR fingerprinting; quantitative imaging; T-2* measurement; MULTIPLE-SCLEROSIS; BRAIN; MRI; T2-ASTERISK; SEQUENCES; IMAGES; T1;
D O I
10.1002/mrm.27556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to estimate PD, T-1, T-2, T-2*, and Delta B-0 simultaneously using magnetic resonance fingerprinting (MRF) with compensation of the linearly varying background field. Methods: MRF based on fast imaging with steady-state precession (FISP) and multi-echo spoiled gradient (SPGR) schemes are alternatively used, which encode T2 and T-2*, respectively. Simulations are performed to determine the appropriate ratio of the FISP and SPGR sections with respect to the T-2 and T-2* accuracy. Additionally, background field inhomogeneity (G(z)) compensation using z-shim gradients are incorporated into the SPGR section and the dictionary. The background field compensation is tested in the phantom experiment under well-shimmed and poor-shimmed conditions. An in vivo experiment is performed and the estimated parameters are compared before and after Gz compensation. Results: The T-1, T-2, and T-2* values from the phantom results are in good agreement with the reference methods under well-shimmed condition. The underestimated T-2 and T-2* values under poor-shimmed condition are recovered by Gz compensation and the parameters are also in good agreement with the reference methods. In the human brain, T-2 and T-2* values are restored by Gz compensation in regions where the magnetic field is particularly inhomogeneous, such as near the sinus and ear canals. Conclusions: The proposed FISP and SPGR combined MRF provides a simultaneous estimation of PD, T-1, T-2, T-2*, and Delta B-0. By incorporating field inhomogeneity as a gradient term into both the sequence and dictionary, T-2 and T-2* values can be restored where field inhomogeneity exists.
引用
收藏
页码:2614 / 2623
页数:10
相关论文
共 50 条
  • [1] MR fingerprinting with simultaneous T1, T2, and fat signal fraction estimation with integrated B0 correction reduces bias in water T1 and T2 estimates
    Ostenson, Jason
    Damon, Bruce M.
    Welch, E. Brian
    MAGNETIC RESONANCE IMAGING, 2019, 60 : 7 - 19
  • [2] Simultaneous bilateral T1, T2, and T1ρ relaxation mapping of the hip joint with magnetic resonance fingerprinting
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn A.
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (05)
  • [3] Magnetic resonance fingerprinting with quadratic RF phase for measurement of T2* simultaneously with δf,T1, and T2
    Wang, Charlie Yi
    Coppo, Simone
    Mehta, Bhairav Bipin
    Seiberlich, Nicole
    Yu, Xin
    Griswold, Mark Alan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1849 - 1862
  • [4] Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T
    Hamilton, Jesse I.
    Pahwa, Shivani
    Adedigba, Joseph
    Frankel, Samuel
    O'Connor, Gregory
    Thomas, Rahul
    Walker, Jonathan R.
    Killinc, Ozden
    Lo, Wei-Ching
    Batesole, Joshua
    Margevicius, Seunghee
    Griswold, Mark
    Rajagopalan, Sanjay
    Gulani, Vikas
    Seiberlich, Nicole
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (04) : 1044 - 1052
  • [5] Simultaneous acquisition for T2 - T2 Exchange and T1 - T2 correlation NMR experiments
    Montrazi, Elton T.
    Lucas-Oliveira, Everton
    Araujo-Ferreira, Arthur G.
    Barsi-Andreeta, Mariane
    Bonagamba, Tito J.
    JOURNAL OF MAGNETIC RESONANCE, 2018, 289 : 63 - 71
  • [6] Magnetic resonance fingerprinting for simultaneous renal T1 and T2*mapping in a single breath-hold
    Hermann, Ingo
    Chacon-Caldera, Jorge
    Brumer, Irene
    Rieger, Benedikt
    Weingartner, Sebastian
    Schad, Lothar R.
    Zoellner, Frank G.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 1940 - 1948
  • [7] T1 and T2 quantification using magnetic resonance fingerprinting in mild traumatic brain injury
    Teresa Gerhalter
    Martijn Cloos
    Anna M. Chen
    Seena Dehkharghani
    Rosemary Peralta
    James S. Babb
    Alejandro Zarate
    Tamara Bushnik
    Jonathan M. Silver
    Brian S. Im
    Stephen Wall
    Steven Baete
    Guillaume Madelin
    Ivan I. Kirov
    European Radiology, 2022, 32 : 1308 - 1319
  • [8] T1 and T2 quantification using magnetic resonance fingerprinting in mild traumatic brain injury
    Gerhalter, Teresa
    Cloos, Martijn
    Chen, Anna M.
    Dehkharghani, Seena
    Peralta, Rosemary
    Babb, James S.
    Zarate, Alejandro
    Bushnik, Tamara
    Silver, Jonathan M.
    Im, Brian S.
    Wall, Stephen
    Baete, Steven
    Madelin, Guillaume
    Kirov, Ivan I.
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 1308 - 1319
  • [9] Simultaneous perfusion, diffusion, T2*, and T1 mapping with MR fingerprinting
    Fan, Hongli
    Bunker, Lisa
    Wang, Zihan
    Durfee, Alexandra Zezinka
    Lin, Doris
    Yedavalli, Vivek
    Ge, Yulin
    Zhou, Xiaohong Joe
    Hillis, Argye E.
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 558 - 569
  • [10] Simultaneous T1, T2, and T1ρ cardiac magnetic resonance fingerprinting for contrast agent-free myocardial tissue characterization
    Velasco, Carlos
    Cruz, Gastao
    Lavin, Begona
    Hua, Alina
    Fotaki, Anastasia
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1992 - 2002