Prospective Clinical Study of Zirconia-Based Posterior Four-Unit Fixed Dental Prostheses: Four-Year Follow-up

被引:0
作者
Salido, Maria P. [1 ]
Martinez-Rus, Francisco [1 ]
del Rio, Fernando [1 ]
Pradies, Guillermo [1 ]
Oezcan, Mutlu [2 ]
Suarez, Maria J. [1 ]
机构
[1] Univ Complutense Madrid, Dept Buccofacial Prostheses, Fac Odontol, E-28040 Madrid, Spain
[2] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent & Oral Med, Dent Mat Unit, Zurich, Switzerland
关键词
PARTIAL DENTURES; FPDS; SURVIVAL; METAANALYSIS; PERFORMANCE; FRAMEWORKS; RATES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this prospective study was to evaluate the clinical performance of zirconia-based posterior four-unit fixed dental prostheses (FDPs) after 4 years of clinical observation. Materials and Methods: Between 2006 and 2010, 10 patients (5 women, 5 men; mean age: 52.8 years) received 17 posterior four-unit FDPs. Two calibrated examiners evaluated the FDPs independently 1 week (baseline), 6 months, and 1, 2, 3, and 4 years after placement using California Dental Association (CDA) criteria. Periodontal status was assessed on both the abutment and contralateral control teeth using Plaque Index, Gingival Index, probing attachment level, and Margin Index parameters. Statistical analysis was performed using descriptive statistics and the Wilcoxon signed-rank test. Results: Three restorations were lost because of fractures at their distal connectors after a mean clinical service of 25.3 months, and one abutment tooth was extracted because of vertical root fracture 23 months after cementation. Three FDPs presented chipping of a moderate size 1 week before framework fracture, and minor chipping was observed in 2 other FDPs 1 week and 36 months after cementation. After 4 years of clinical service, the cumulative survival rate of the posterior four-unit FDPs was 76.5%. No caries lesions were detected on the abutment teeth. The remaining restorations were judged to be satisfactory according to the CDA criteria. Periodontal parameters did not show significant differences between test and control teeth, but Gingival Index scores demonstrated a slight increase in inflammation in the distal abutments after 4 years (P = 016). Conclusions: The use of zirconia-based posterior four-unit FDPs should be restricted for patients with high esthetic demands, except in patients where at least 4 mm of height is available for connector thickness. Int J Prosthodont 2012;25:403-409.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 31 条
  • [1] Clinical trials in zirconia: a systematic review
    Al-Amleh, B.
    Lyons, K.
    Swain, M.
    [J]. JOURNAL OF ORAL REHABILITATION, 2010, 37 (08) : 641 - 652
  • [2] [Anonymous], 1977, QUAL EV DENT CAR GUI
  • [3] Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
    Beuer, Florian
    Edelhoff, Daniel
    Gernet, Wolfgang
    Sorensen, John A.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) : 445 - 451
  • [4] Current ceramic materials and systems with clinical recommendations: A systematic review
    Conrad, Heather J.
    Seong, Wook-Jin
    Pesun, Gor J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (05) : 389 - 404
  • [5] A METAANALYSIS OF DURABILITY DATA ON CONVENTIONAL FIXED BRIDGES
    CREUGERS, NHJ
    KAYSER, AF
    VANTHOF, MA
    [J]. COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1994, 22 (06) : 448 - 452
  • [6] State of the art of zirconia for dental applications
    Denry, Isabelle
    Kelly, J. Robert
    [J]. DENTAL MATERIALS, 2008, 24 (03) : 299 - 307
  • [7] Dündar M, 2005, INT J PROSTHODONT, V18, P71
  • [8] Esquivel-Upshaw JF, 2004, INT J PROSTHODONT, V17, P469
  • [9] Heintze SD, 2010, INT J PROSTHODONT, V23, P493
  • [10] Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter.: An in-vitro study
    Larsson, C.
    Holm, L.
    Lovgren, N.
    Kokubo, Y.
    von Steyern, P. Vult