Non-invasive assessment of cardiac output at rest and during exercise by finger plethysmography

被引:9
|
作者
Critoph, Christopher H. [1 ]
Patel, Vimal [1 ]
Mist, Bryan [1 ]
Thomas, Martin D. [1 ]
Elliott, Perry M. [1 ]
机构
[1] UCL, Inst Cardiovasc Sci, Heart Hosp, London W1G 8PH, England
关键词
acetylene uptake; cycle ergometer; haemodynamics; Modelflow; pulse waveform analysis; BRACHIAL-ARTERY PRESSURE; MAXIMAL AEROBIC EXERCISE; AORTIC INPUT IMPEDANCE; DIRECT FICK METHOD; PHASE-CONTRAST MR; HEART-FAILURE; STROKE VOLUME; DOPPLER-ECHOCARDIOGRAPHY; OXYGEN-CONSUMPTION; REBREATHING METHOD;
D O I
10.1111/cpf.12032
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: We sought to determine the accuracy of finger plethysmography using pulse waveform analysis with brachial calibration for measurement of cardiac output during submaximal exercise by comparing it against an acetylene (C2H2) uptake technique. Methods: The study included 24 healthy volunteers (12 males, age 35 +/- 8 years). Testing was performed on an upright cycle ergometer using an incremental protocol. Cardiac output measurements were performed at rest and during sub-maximal exercise using a single breath C2H2 uptake technique and continuously using finger plethysmography with brachial calibration. Results: Valid results at rest and during sub-maximal exercise were achieved in 20 of 24 participants. Cardiac output at rest was 5.3 +/- 1.1 and 5.2 +/- 1.2 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.712. Mean difference between techniques was -0.1 +/- 0.5 l min(-1). Cardiac output during submaximal exercise was 10.2 +/- 2.3 and 10.3 +/- 2.1 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.898. Mean difference between techniques was 0.1 +/- 1.5 l min(-1). The overall correlation between finger plethysmography and C2H2 data obtained during rest and exercise was r(2) = 0.872, P<0.0001. Mean rise in cardiac output during exercise was 4.9 +/- 1.5 (finger plethysmography) and 5.1 +/- 1.5 l min(-1) (C2H2), P = 0.64. Conclusion: Finger plethysmography determined cardiac output values both at rest and during sub-maximal exercise are comparable with those obtained using a single breath C2H2 uptake technique.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [41] Non-invasive Cardiac Output Monitoring in Neonates
    O'Neill, Roisin
    Dempsey, Eugene M.
    Garvey, Aisling A.
    Schwarz, Christoph E.
    FRONTIERS IN PEDIATRICS, 2021, 8
  • [42] NON-INVASIVE CARDIAC-OUTPUT MEASUREMENT
    MACKAY, RS
    MICROVASCULAR RESEARCH, 1972, 4 (04) : 438 - &
  • [43] Non-invasive assessment of pulmonary microcirculation at rest and exercise in patients with previous pulmonary thromboembolism
    Berton, Danilo Cortozi
    Marques, Renata Diniz
    Palmer, Brandon
    D'Arsigny, Christine
    O'Donnell, Denis E.
    Neder, J. Alberto
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [44] Medical Technology Non-invasive Cardiac output Measurement according to Fick at rest and under Load
    不详
    JOURNAL FUR KARDIOLOGIE, 2008, 15 (9-10): : 326 - 326
  • [45] CONTINUOUS NON-INVASIVE ASSESSMENT OF CARDIAC OUTPUT DURING FLUID THERAPY IN SEPTIC PATIENTS IN THE EMERGENCY DEPARTMENT
    van der Wouden, G. M.
    Harms, M. P.
    Ligtenberg, J.
    ter Maaten, J. C.
    INTENSIVE CARE MEDICINE, 2013, 39 : S479 - S479
  • [46] Study to investigate the correlation between non-invasive cardiac output monitoring and oxygen consumption during exercise testing
    Wood, J.
    Bryan, A.
    Moore, J. A.
    Benington, S.
    Parker, M.
    Gall, I.
    Jepegnanam, C.
    Foster, P. N.
    Atkinson, D.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (05) : 875 - 876
  • [47] Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods
    Liu, Y. H.
    Dhakal, B. P.
    Keesakul, C.
    Kacmarek, R. M.
    Lewis, G. D.
    Jiang, Y.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 129 - 131
  • [49] Non-Invasive Assessment of Cardiac Output: A Method Whose Time Has Come?
    Hardin, Elizabeth A.
    Stoller, Douglas
    Hieda, Michinari
    Sarma, Satyam
    Levine, Ben
    CIRCULATION, 2017, 136
  • [50] The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: A review
    Newman, DG
    Callister, R