Non-invasive assessment of cardiac output at rest and during exercise by finger plethysmography

被引:9
|
作者
Critoph, Christopher H. [1 ]
Patel, Vimal [1 ]
Mist, Bryan [1 ]
Thomas, Martin D. [1 ]
Elliott, Perry M. [1 ]
机构
[1] UCL, Inst Cardiovasc Sci, Heart Hosp, London W1G 8PH, England
关键词
acetylene uptake; cycle ergometer; haemodynamics; Modelflow; pulse waveform analysis; BRACHIAL-ARTERY PRESSURE; MAXIMAL AEROBIC EXERCISE; AORTIC INPUT IMPEDANCE; DIRECT FICK METHOD; PHASE-CONTRAST MR; HEART-FAILURE; STROKE VOLUME; DOPPLER-ECHOCARDIOGRAPHY; OXYGEN-CONSUMPTION; REBREATHING METHOD;
D O I
10.1111/cpf.12032
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: We sought to determine the accuracy of finger plethysmography using pulse waveform analysis with brachial calibration for measurement of cardiac output during submaximal exercise by comparing it against an acetylene (C2H2) uptake technique. Methods: The study included 24 healthy volunteers (12 males, age 35 +/- 8 years). Testing was performed on an upright cycle ergometer using an incremental protocol. Cardiac output measurements were performed at rest and during sub-maximal exercise using a single breath C2H2 uptake technique and continuously using finger plethysmography with brachial calibration. Results: Valid results at rest and during sub-maximal exercise were achieved in 20 of 24 participants. Cardiac output at rest was 5.3 +/- 1.1 and 5.2 +/- 1.2 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.712. Mean difference between techniques was -0.1 +/- 0.5 l min(-1). Cardiac output during submaximal exercise was 10.2 +/- 2.3 and 10.3 +/- 2.1 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.898. Mean difference between techniques was 0.1 +/- 1.5 l min(-1). The overall correlation between finger plethysmography and C2H2 data obtained during rest and exercise was r(2) = 0.872, P<0.0001. Mean rise in cardiac output during exercise was 4.9 +/- 1.5 (finger plethysmography) and 5.1 +/- 1.5 l min(-1) (C2H2), P = 0.64. Conclusion: Finger plethysmography determined cardiac output values both at rest and during sub-maximal exercise are comparable with those obtained using a single breath C2H2 uptake technique.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [31] Non-invasive assessment of cardiac output during exercise in healthy young humans: comparison between Modelflow method and Doppler echocardiography method
    Sugawara, J
    Tanabe, T
    Miyachi, M
    Yamamoto, K
    Takahashi, K
    Iemitsu, M
    Otsuki, T
    Homma, S
    Maeda, S
    Ajisaka, R
    Matsuda, M
    ACTA PHYSIOLOGICA SCANDINAVICA, 2003, 179 (04): : 361 - 366
  • [32] In reply: Non-invasive cardiac output monitoring during sinus surgery
    So Hui Yun
    Hyun Jung Kim
    Journal of Anesthesia, 2015, 29 : 640 - 640
  • [33] In reply: Non-invasive cardiac output monitoring during sinus surgery
    Yun, So Hui
    Kim, Hyun Jung
    JOURNAL OF ANESTHESIA, 2015, 29 (04) : 640 - 640
  • [34] NON-INVASIVE OSCILLOMETRIC CARDIAC OUTPUT CALCULATION
    Reshetnik, A.
    Schoelzel, A.
    Compton, F.
    Toelle, M.
    Zidek, M.
    van der Giet, M.
    JOURNAL OF HYPERTENSION, 2017, 35 : E120 - E120
  • [35] Model for non-invasive cardiac output measurement
    Wassertheurer, Siegfried
    Mayer, Christopher
    Breitenecker, Felix
    AMS 2007: FIRST ASIA INTERNATIONAL CONFERENCE ON MODELLING & SIMULATION ASIA MODELLING SYMPOSIUM, PROCEEDINGS, 2007, : 580 - +
  • [36] Search for a non-invasive cardiac output monitor
    Thom, Ogilvie
    EMERGENCY MEDICINE AUSTRALASIA, 2008, 20 (03) : 199 - 200
  • [37] Non-invasive cardiac output (NICO) monitor
    Sutton, D
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (01) : 81 - 81
  • [38] Non-invasive cardiac output monitoring in neonates
    Meyer, Sascha
    Todd, David
    Shadboldt, Bruce
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2010, 95 (06): : F464 - F464
  • [39] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT
    LASZLO, G
    BOONZAIER, D
    WELLS, PNT
    BIOMEDICAL ENGINEERING, 1974, 9 (08): : 362 - 364
  • [40] Non-invasive monitoring of cardiac output - Reply
    Huber, T
    Segiet, W
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1998, 39 (02): : 102 - 103