Non-invasive assessment of cardiac output at rest and during exercise by finger plethysmography

被引:9
|
作者
Critoph, Christopher H. [1 ]
Patel, Vimal [1 ]
Mist, Bryan [1 ]
Thomas, Martin D. [1 ]
Elliott, Perry M. [1 ]
机构
[1] UCL, Inst Cardiovasc Sci, Heart Hosp, London W1G 8PH, England
关键词
acetylene uptake; cycle ergometer; haemodynamics; Modelflow; pulse waveform analysis; BRACHIAL-ARTERY PRESSURE; MAXIMAL AEROBIC EXERCISE; AORTIC INPUT IMPEDANCE; DIRECT FICK METHOD; PHASE-CONTRAST MR; HEART-FAILURE; STROKE VOLUME; DOPPLER-ECHOCARDIOGRAPHY; OXYGEN-CONSUMPTION; REBREATHING METHOD;
D O I
10.1111/cpf.12032
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: We sought to determine the accuracy of finger plethysmography using pulse waveform analysis with brachial calibration for measurement of cardiac output during submaximal exercise by comparing it against an acetylene (C2H2) uptake technique. Methods: The study included 24 healthy volunteers (12 males, age 35 +/- 8 years). Testing was performed on an upright cycle ergometer using an incremental protocol. Cardiac output measurements were performed at rest and during sub-maximal exercise using a single breath C2H2 uptake technique and continuously using finger plethysmography with brachial calibration. Results: Valid results at rest and during sub-maximal exercise were achieved in 20 of 24 participants. Cardiac output at rest was 5.3 +/- 1.1 and 5.2 +/- 1.2 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.712. Mean difference between techniques was -0.1 +/- 0.5 l min(-1). Cardiac output during submaximal exercise was 10.2 +/- 2.3 and 10.3 +/- 2.1 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.898. Mean difference between techniques was 0.1 +/- 1.5 l min(-1). The overall correlation between finger plethysmography and C2H2 data obtained during rest and exercise was r(2) = 0.872, P<0.0001. Mean rise in cardiac output during exercise was 4.9 +/- 1.5 (finger plethysmography) and 5.1 +/- 1.5 l min(-1) (C2H2), P = 0.64. Conclusion: Finger plethysmography determined cardiac output values both at rest and during sub-maximal exercise are comparable with those obtained using a single breath C2H2 uptake technique.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [1] NON-INVASIVE ASSESSMENT OF CARDIAC-OUTPUT AT REST AND EXERCISE USING DOPPLER ULTRASOUND
    BENNETT, ED
    MEHTA, N
    IYAWE, V
    CUMMIN, ARC
    BRITISH HEART JOURNAL, 1984, 51 (06): : 690 - 690
  • [2] NON-INVASIVE DETERMINATION OF THE DISTRIBUTION OF CARDIAC-OUTPUT IN MAN AT REST AND DURING EXERCISE
    SVENSSON, SE
    LOMSKY, M
    OLSSON, L
    PERSSON, S
    STRAUSS, HW
    WESTLING, H
    CLINICAL PHYSIOLOGY, 1982, 2 (06): : 467 - 477
  • [3] Non-invasive assessment of cardiac output during stress test
    Di Tante, V
    Romano, M
    Gensini, G
    Guerrisi, A
    Galanti, G
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S27 - S27
  • [4] Non-invasive cardiac output evaluation during progressive exercise test
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Oswald-Mammoser, M
    Mettauer, B
    Lampert, E
    Lonsdorfer, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 440 (06): : R268 - R268
  • [5] CARDIAC EFFECTS OF PROPRANOLOL AND TIMOLOL IN HYPERTENSION - ASSESSMENT BY 4 NON-INVASIVE METHODS AT REST AND DURING EXERCISE
    MORIOKA, S
    MORIYAMA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1983, 47 (08): : 873 - 874
  • [6] Non-invasive assessment of cardiac output in children
    Richardson, JR
    Ferguson, J
    Hiscox, J
    Rawles, J
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1998, 15 (05): : 304 - 307
  • [7] Non-invasive cardiac output assessment in children
    Childs, C
    Dark, P
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1999, 16 (02): : 158 - 158
  • [8] NON-INVASIVE CARDIAC-OUTPUT MONITORING DURING EXERCISE STRESS TEST
    NANNA, M
    CHANDRARATNA, PAN
    NIMALASURIYA, A
    KAWANISHI, D
    MCKAY, C
    KOTLEWSKI, A
    RAHIMTOOLA, S
    CIRCULATION, 1983, 68 (04) : 10 - 10
  • [9] Non-invasive Assessment of Fecal Stress Biomarkers in Hunting Dogs During Exercise and at Rest
    Zannoni, Augusta
    Pietra, Marco
    Gaspardo, Alba
    Accorsi, Pier Attilio
    Barone, Monica
    Turroni, Silvia
    Laghi, Luca
    Zhu, Chenglin
    Brigidi, Patrizia
    Forni, Monica
    FRONTIERS IN VETERINARY SCIENCE, 2020, 7
  • [10] A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method
    Anne Charloux
    Evelyne Lonsdorfer-Wolf
    Ruddy Richard
    Eliane Lampert
    Monique Oswald-Mammosser
    Bertrand Mettauer
    Bernard Geny
    Jean Lonsdorfer
    European Journal of Applied Physiology, 2000, 82 : 313 - 320