Gait assessment during the initial fitting of customized selective laser sintering ankle foot orthoses in subjects with drop foot

被引:55
作者
Creylman, Veerle [1 ,2 ]
Muraru, Luiza [1 ,2 ]
Pallari, Jari [3 ,4 ]
Vertommen, Helga [1 ]
Peeraer, Louis [1 ,5 ]
机构
[1] KHKempen Univ Coll, MOBILAB, Geel, Belgium
[2] Katholieke Univ Leuven, Div Biomech BMe, Louvain, Belgium
[3] Materialise Heverlee, Heverlee, Belgium
[4] Peacocks Med Grp Ltd, Newcastle Upon Tyne, Tyne & Wear, England
[5] Katholieke Univ Leuven, Fac Kinesiol & Rehabil Sci, Dept Rehabil Sci, Louvain, Belgium
关键词
AFO; ankle foot orthosis; gait analysis; additive manufacturing; SLS; FABRICATION; HEMIPLEGIA; TRIAL;
D O I
10.1177/0309364612451269
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Recently, additive fabrication has been proposed as a feasible engineering method for manufacturing of customized ankle foot orthoses (AFOs). Consequently, studies on safety, comfort and effectiveness are now carried out to assess the performance of such devices. Objective: Evaluate the clinical performance of customized (selective laser sintering) SLS-AFOs on eight subjects with unilateral drop foot gait and compare to clinically accepted (polypropylene) PP-AFOs. Study Design: Active control trial. Methods: For each subject two customized AFOs were fabricated: one SLS-AFO manufactured following an additive fabrication framework and one thermoplastic PP-AFO manufactured according to the traditional handcraft method. Clinical performance of both AFOs was evaluated during gait analysis. Results: A significant beneficial effect of both custom-moulded PP-AFO and customized SLS-AFO in terms of spatial temporal gait parameters and ankle kinematic parameters compared to barefoot gait of adults with drop foot gait are observed. No statistically significant difference between the effect of PP-AFO and of SLS-AFO was found in terms of spatial temporal gait parameters and ankle kinematic parameters. Conclusion: AFOs manufactured through the SLS technique show performances that are at least equivalent to the hand-crafted PP-AFOs commonly prescribed in current clinical practice.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1992, GAIT ANAL NORMAL PAT
[2]  
[Anonymous], 2010, P 21 ANN INT SOL FRE
[3]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[4]  
Bleyenheuft C., 2008, Annales de Readaptation et de Medecine Physique, V51, P154, DOI 10.1016/j.annrmp.2007.12.005
[5]  
BURDETT RG, 1988, PHYS THER, V68, P1197
[6]  
Chu TT, 2011, TOP STROKE REHABIL, V7, P19
[7]   The modern era of orthotics [J].
Condie, David N. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2008, 32 (03) :313-323
[8]   A three centre study of the variability of ankle foot orthoses due to fabrication and grade of polypropylene [J].
Convery, P ;
Greig, RJ ;
Ross, RS ;
Sockalingam, S .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2004, 28 (02) :175-182
[9]  
Dieli J., 1997, J PROSTHET ORTHOT, V9, P82, DOI 10.1097/00008526-199704000-00007
[10]   Manufacture of passive dynamic ankle-foot orthoses using selective laser sintering [J].
Faustini, Mario C. ;
Neptune, Richard R. ;
Crawford, Richard H. ;
Stanhope, Steven J. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) :784-790