Turbutest™ in the training of asthmatic Turbuhaler™ users

被引:10
作者
Ferreira, MB [1 ]
Santos, A [1 ]
Clode, MH [1 ]
Carlos, AGP [1 ]
机构
[1] Hosp Santa Maria, Immunoallergol Unit, Serv Med 3, P-1699 Lisbon, Portugal
关键词
asthma; compliance; inhalers; therapy;
D O I
10.1034/j.1398-9995.1999.00969.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Correct utilization of inhalation devices is a key factor in asthma management. Objective assessment of the ability to use inhaler devices is therefore fundamental. Methods: The objective was to assess objectively the inhalation technique of Turbuhaler(TM) users who reported having no difficulty in using such a device. A total of 600 asthmatic patients of our allergology outpatient department, daily users of Turbuhaler devices, were evaluated with Turbutest(TM). This is a simple portable apparatus which connects a Turbuhaler inhaler with an electronic device to allow semiquantitative assessment of inhalation technique, with a score ranging from 0 (worst) to 3 (best), readily visualized on the apparatus. Patients were allowed to practice with Turbutest, assisted by an allergologist, until they improved their scores. A second Turbutest assessment was performed at a 2-month follow-up visit. Results: On the first assessment, one-third of the patients had scores inadequate to allow a good inhalation, and only 20% achieved a score of 3. On the second assessment, significantly higher Turbutest scores were observed. Conclusions: Turbutest is a valuable tool in asthmatic patients' training, allowing identification and improvement of an inadequate inhalation technique with Turbuhaler.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 9 条
[1]  
BRAUNSTEIN G, 1992, REV MAL RESPIR, V9, pR83
[2]   PEAK INSPIRATORY FLOW-THROUGH TURBUHALER(R) IN ACUTE ASTHMA [J].
BROWN, PH ;
NING, ACWS ;
GREENING, AP ;
MCLEAN, A ;
CROMPTON, GK .
EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (11) :1940-1941
[3]   Comparative lung delivery of salbutamol given via Turbuhaler and Diskus dry powder inhaler devices [J].
Lipworth, BJ ;
Clark, DJ .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 53 (01) :47-49
[4]   Relative efficacy of three different inhalers containing salbutamol in patients with asthma [J].
Mahadewsingh, JV ;
Hamersma, WBGJ ;
Schreurs, AJM .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1996, 50 (06) :467-469
[5]   ASSESSMENT OF PATIENT ACCEPTANCE AND INHALATION TECHNIQUE OF A PRESSURIZED AEROSOL INHALER AND 2 BREATH-ACTUATED DEVICES [J].
NIMMO, CJR ;
CHEN, DNM ;
MARTINUSEN, SM ;
USTAD, TL ;
OSTROW, DN .
ANNALS OF PHARMACOTHERAPY, 1993, 27 (7-8) :922-927
[6]  
Pedersen S, 1996, RESP MED, V90, P69, DOI 10.1016/S0954-6111(96)90201-2
[7]  
Schlaeppi M, 1996, BRIT J CLIN PRACT, V50, P14
[8]   CLINICAL EFFICACY OF BUDESONIDE TURBUHALER(R) COMPARED WITH THAT OF BECLOMETHASONE DIPROPIONATE PMDI WITH VOLUMATIC SPACER - A 2-YEAR RANDOMIZED STUDY IN 102 ASTHMA PATIENTS [J].
SELROOS, O ;
BACKMAN, R ;
FORSEN, KO ;
LOFROOS, AB ;
NIEMISTO, M ;
PIETINALHO, A ;
RISKA, H .
ALLERGY, 1994, 49 (10) :833-836
[9]  
VICHYANOND P, 1994, ASIAN PAC J ALLERGY, V12, P1