Metal-Organic Framework Nanomaterials as Novel Signal Probes for Electron Transfer Mediated Ultrasensitive Electrochemical Immunoassay

被引:175
作者
Liu, Ting-Zhi [1 ]
Hu, Rong [1 ]
Zhang, Xi [1 ]
Zhang, Kun-Lei [1 ]
Liu, Yi [1 ]
Zhang, Xiao-Bing [2 ]
Bai, Ru-Yan [1 ]
Li, Delei [1 ]
Yang, Yun-Hui [1 ]
机构
[1] Yunnan Normal Univ, Coll Chem & Chem Engn, Kunming 650092, Yunnan, Peoples R China
[2] Hunan Univ, Collaborat Innovat Ctr Mol Engn Theronast, Coll Chem & Chem Engn, Mol Sci & Biomed Lab,State Key Lab Chemo Biosensi, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
HIGHLY SENSITIVE DETECTION; GOLD NANOPARTICLES; DNA; CATALYSTS; LABEL; IMMUNOSENSOR; CRYSTALLINE; BIOMARKERS; PARTICLES; PLATFORM;
D O I
10.1021/acs.analchem.6b04191
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and simple electrochemical immunoassay for C-reactive protein was developed using metal-organic frameworks (Au-MOFs) as signal unit. In this study, we found MOFs could be used as signal probe. And this new class of signal probe differs from traditional probe. The signal of the copper ions (Cu2+) from MOFs could be directly detected without acid dissolution and preconcentration, which would greatly simplify the detection steps and reduce the detection time. Moreover, MOFs contain large amounts of Cu2+ ions, providing high electrochemical signals. Our report represents the first example of using MOFs themselves as electrochemical signal probe for biosensors. Platinum nanoparticle modified covalent organic frameworks (Pt-COFs) with high electronic conductivity was employed as the substrate, which is the first time demonstrating the use of Pt-COFs for electrochemical immunoassay. Under the optimized experimental conditions, the proposed sensing strategy provides a linear dynamic ranging from 1 to 400 ng/mL. A detection limit of 0.2 ng/mL was obtained, indicating an improved analytical performance. With these merits, this stable, simple, low-cost, sensitive and selective electrochemical immunoassay shows promise for applications in the point-of-care diagnostics of dieses and environmental monitoring.
引用
收藏
页码:12516 / 12523
页数:8
相关论文
共 42 条
[21]   Label-free detection of C-reactive protein using highly dispersible gold nanoparticles synthesized by reducible biomimetic block copolymers [J].
Iwasaki, Yasuhiko ;
Kimura, Toshihiro ;
Orisaka, Masaki ;
Kawasaki, Hideya ;
Goda, Tatsuro ;
Yusa, Shin-ichi .
CHEMICAL COMMUNICATIONS, 2014, 50 (42) :5656-5658
[22]   High-Performance Liquid Chromatographic Enantioseparation of Racemic Drugs Based on Homochiral Metal-Organic Framework [J].
Kuang, Xuan ;
Ma, Yu ;
Su, Hao ;
Zhang, Jine ;
Dong, Yu-Bin ;
Tang, Bo .
ANALYTICAL CHEMISTRY, 2014, 86 (02) :1277-1281
[23]   Magnetic Graphene Nanosheet-Based Microfluidic Device for Homogeneous Real-Time Electronic Monitoring of Pyrophosphatase Activity Using Enzymatic Hydrolysate-Induced Release of Copper Ion [J].
Lin, Youxiu ;
Zhou, Qian ;
Li, Juan ;
Shu, Jian ;
Qiu, Zhenli ;
Lin, Yuping ;
Tang, Dianping .
ANALYTICAL CHEMISTRY, 2016, 88 (01) :1030-1038
[24]   Porphyrin-Encapsulated Metal-Organic Frameworks as Mimetic Catalysts for Electrochemical DNA Sensing via Allosteric Switch of Hairpin DNA [J].
Ling, Pinghua ;
Lei, Jianping ;
Zhang, Lei ;
Ju, Huangxian .
ANALYTICAL CHEMISTRY, 2015, 87 (07) :3957-3963
[25]   Ultrasensitive Immunosensor for Cancer Biomarker Proteins Using Gold Nanoparticle Film Electrodes and Multienzyme-Particle Amplification [J].
Mani, Vigneshwaran ;
Chikkaveeraiah, Bhaskara V. ;
Patel, Vyomesh ;
Gutkind, J. Silvio ;
Rusling, James F. .
ACS NANO, 2009, 3 (03) :585-594
[26]   A plasmonic chip-based bio/chemical hybrid sensing system for the highly sensitive detection of C-reactive protein [J].
Matsuura, Ryo ;
Tawa, Keiko ;
Kitayama, Yukiya ;
Takeuchi, Toshifumi .
CHEMICAL COMMUNICATIONS, 2016, 52 (20) :3883-3886
[27]   Evaluating the role of biomarkers for cardiovascular risk prediction: focus on CRP, BNP and urinary microalbumin [J].
May, Abigail ;
Wang, Thomas J. .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2007, 7 (06) :793-804
[28]   Zeolitic Imidazole Framework-8 Catalysts in the Conversion of CO2 to Chloropropene Carbonate [J].
Miralda, Carmen M. ;
Macias, Eugenia E. ;
Zhu, Minqi ;
Ratnasamy, Paul ;
Carreon, Moises A. .
ACS CATALYSIS, 2012, 2 (01) :180-183
[29]   CDC/AHA Workshop on Markers of Inflammation and Cardiovascular Disease - Application to Clinical and Public Health Practice - Report from the laboratory science discussion group [J].
Myers, GL ;
Rifai, N ;
Tracy, RP ;
Roberts, WL ;
Alexander, RW ;
Biasucci, LM ;
Catravas, JD ;
Cole, TG ;
Cooper, GR ;
Khan, BV ;
Kimberly, MM ;
Stein, EA ;
Taubert, KA ;
Warnick, GR ;
Waymack, PP .
CIRCULATION, 2004, 110 (25) :E545-E549
[30]   The influence of statin treatment on the inflammatory biomarkers YKL-40 and HsCRP in patients with stable coronary artery disease [J].
Mygind, Naja Dam ;
Harutyunyan, Marina J. ;
Mathiasen, Anders Bruun ;
Ripa, Rasmus S. ;
Thune, Jens Jacob ;
Gotze, Jens Peter ;
Johansen, Julia S. ;
Kastrup, Jens .
INFLAMMATION RESEARCH, 2011, 60 (03) :281-287