Viscoelasticity of blood and viscoelastic blood analogues for use in polydymethylsiloxane in vitro models of the circulatory system

被引:120
作者
Campo-Deano, Laura [1 ]
Dullens, Roel P. A. [2 ]
Aarts, Dirk G. A. L. [2 ]
Pinho, Fernando T. [1 ]
Oliveira, Monica S. N. [3 ]
机构
[1] Univ Porto, Fac Engn, Ctr Estudos Fenomenos Transporte, P-4200465 Oporto, Portugal
[2] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[3] Univ Strathclyde, Dept Mech & Aerosp Engn, Glasgow G1 1XJ, Lanark, Scotland
基金
英国工程与自然科学研究理事会;
关键词
NONHOMOGENEOUS CONSTITUTIVE MODEL; YIELD-STRESS; HEMATOCRIT DEPENDENCE; SOFT LITHOGRAPHY; REFRACTIVE-INDEX; COMPLEX FLUIDS; STEADY FLOW; VISCOSITY; MICRORHEOLOGY; RHEOLOGY;
D O I
10.1063/1.4804649
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The non-Newtonian properties of blood are of great importance since they are closely related with incident cardiovascular diseases. A good understanding of the hemodynamics through the main vessels of the human circulatory system is thus fundamental in the detection and especially in the treatment of these diseases. Very often such studies take place in vitro for convenience and better flow control and these generally require blood analogue solutions that not only adequately mimic the viscoelastic properties of blood but also minimize undesirable optical distortions arising from vessel curvature that could interfere in flow visualizations or particle image velocimetry measurements. In this work, we present the viscoelastic moduli of whole human blood obtained by means of passive microrheology experiments. These results and existing shear and extensional rheological data for whole human blood in the literature enabled us to develop solutions with rheological behavior analogous to real whole blood and with a refractive index suited for PDMS (polydymethylsiloxane) micro-and milli-channels. In addition, these blood analogues can be modified in order to obtain a larger range of refractive indices from 1.38 to 1.43 to match the refractive index of several materials other than PDMS. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:11
相关论文
共 61 条
[1]   A pillar-based microfilter for isolation of white blood cells on elastomeric substrate [J].
Alvankarian, Jafar ;
Bahadorimehr, Alireza ;
Majlis, Burhanuddin Yeop .
BIOMICROFLUIDICS, 2013, 7 (01)
[2]   Experimental investigation of the flow of a blood analogue fluid in a replica of a bifurcated small artery [J].
Anastasiou, A. D. ;
Spyrogianni, A. S. ;
Koskinas, K. C. ;
Giannoglou, G. D. ;
Paras, S. V. .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (02) :211-218
[3]  
BAAIJENS JPW, 1993, BIORHEOLOGY, V30, P63
[4]  
Barnes H. A., 2000, HDB ELEMENTARY RHEOL
[5]  
Bird R.B., 1987, Dynamics of Polymeric Liquids: Volume 1, Fluid Mechanics, V1
[6]   Microrheology as a tool for high-throughput screening [J].
Breedveld, V ;
Pine, DJ .
JOURNAL OF MATERIALS SCIENCE, 2003, 38 (22) :4461-4470
[7]   Rheology of Human Blood Plasma: Viscoelastic Versus Newtonian Behavior [J].
Brust, M. ;
Schaefer, C. ;
Doerr, R. ;
Pan, L. ;
Garcia, M. ;
Arratia, P. E. ;
Wagner, C. .
PHYSICAL REVIEW LETTERS, 2013, 110 (07)
[8]   REFRACTIVE-INDEX MATCHING METHODS FOR LIQUID FLOW INVESTIGATIONS [J].
BUDWIG, R .
EXPERIMENTS IN FLUIDS, 1994, 17 (05) :350-355
[9]  
CASSON N, 1959, RHEOLOGY DISPERSE SY, pCH5
[10]   BLOOD VISCOSITY - INFLUENCE OF ERYTHROCYTE DEFORMATION [J].
CHIEN, S ;
USAMI, S ;
DELLENBACK, RJ ;
GREGERSEN, MI .
SCIENCE, 1967, 157 (3790) :827-+