Use of 4-Dimensional Computed Tomography-Based Ventilation Imaging to Correlate Lung Dose and Function With Clinical Outcomes

被引:110
作者
Vinogradskiy, Yevgeniy [1 ]
Castillo, Richard [2 ]
Castillo, Edward [3 ,4 ]
Tucker, Susan L. [5 ,6 ]
Liao, Zhongxing [3 ]
Guerrero, Thomas [3 ,4 ]
Martel, Mary K. [2 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Rice Univ, Dept Computat & Appl Math, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Bioinformat, Houston, TX 77030 USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Computat Biol, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2013年 / 86卷 / 02期
基金
美国国家卫生研究院;
关键词
TISSUE EXPANSION; RADIOTHERAPY; CANCER; AVOIDANCE;
D O I
10.1016/j.ijrobp.2013.01.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Four-dimensional computed tomography (4DCT)-based ventilation is an emerging imaging modality that can be used in the thoracic treatment planning process. The clinical benefit of using ventilation images in radiation treatment plans remains to be tested. The purpose of the current work was to test the potential benefit of using ventilation in treatment planning by evaluating whether dose to highly ventilated regions of the lung resulted in increased incidence of clinical toxicity. Methods and Materials: Pretreatment 4DCT data were used to compute pretreatment ventilation images for 96 lung cancer patients. Ventilation images were calculated using 4DCT data, deformable image registration, and a density-change based algorithm. Dose-volume and ventilation-based dose function metrics were computed for each patient. The ability of the dose-volume and ventilation-based dose-function metrics to predict for severe (grade 3+) radiation pneumonitis was assessed using logistic regression analysis, area under the curve (AUC) metrics, and bootstrap methods. Results: A specific patient example is presented that demonstrates how incorporating ventilation-based functional information can help separate patients with and without toxicity. The logistic regression significance values were all lower for the dose-function metrics (range P=.093-.250) than for their dose-volume equivalents (range, P=.331-.580). The AUC values were all greater for the dose-function metrics (range, 0.569-0.620) than for their doseevolume equivalents (range, 0.500-0.544). Bootstrap results revealed an improvement in model fit using doseefunction metrics compared to doseevolume metrics that approached significance (range, P=.118-.155). Conclusions: To our knowledge, this is the first study that attempts to correlate lung dose and 4DCT ventilation-based function to thoracic toxicity after radiation therapy. Although the results were not significant at the .05 level, our data suggests that incorporating ventilation-based functional imaging can improve prediction for radiation pneumonitis. We present an important first step toward validating the use of 4DCT-based ventilation imaging in thoracic treatment planning. (C) 2013 Elsevier Inc.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 20 条
[1]   Four-dimensional deformable image registration using trajectory modeling [J].
Castillo, Edward ;
Castillo, Richard ;
Martinez, Josue ;
Shenoy, Maithili ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) :305-327
[2]   Ventilation from four-dimensional computed tomography: density versus Jacobian methods [J].
Castillo, Richard ;
Castillo, Edward ;
Martinez, Josue ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) :4661-4685
[3]   Reproducibility of registration-based measures of lung tissue expansion [J].
Du, Kaifang ;
Bayouth, John E. ;
Cao, Kunlin ;
Christensen, Gary E. ;
Ding, Kai ;
Reinhardt, Joseph M. .
MEDICAL PHYSICS, 2012, 39 (03) :1595-1608
[4]  
Guerrero T, 2006, PHYS MED BIOL, V51, P777, DOI [10.1088/0031-9155/51/4/002, 10.1088/0031-9155/-51/4/002]
[5]   Dose-volume thresholds and smoking status for the risk of treatment-related pneumonitis in inoperable non-small cell lung cancer treated with definitive radiotherapy [J].
Jin, Hekun ;
Tucker, Susan L. ;
Liu, Hui Helen ;
Wei, Xiong ;
Yom, Sue Sun ;
Wang, Shulian ;
Komaki, Ritsuko ;
Chen, Yuhchyau ;
Martel, Mary K. ;
Mohan, Radhe ;
Cox, James D. ;
Liao, Zhongxing .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :427-432
[6]   Prospective assessment of models to predict radiation pneumonitis based on dosimetric/functional parameters [J].
Kocak, Z ;
Zhou, S ;
Kahn, D ;
Hollis, D ;
Clough, R ;
Folz, RJ ;
Anscher, MS ;
Larrier, N ;
Marks, LB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02) :S388-S388
[7]   Receiver operating characteristic curves to assess predictors of radiation-induced symptomatic lung injury [J].
Lind, PA ;
Marks, LB ;
Hollis, D ;
Fan, M ;
Zhou, SM ;
Munley, MT ;
Shafman, TD ;
Jaszczak, RJ ;
Coleman, RE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (02) :340-347
[8]   Incorporation of functional status into dose-volume analysis [J].
Marks, LB ;
Sherouse, GW ;
Munley, MT ;
Bentel, GC ;
Spencer, DP .
MEDICAL PHYSICS, 1999, 26 (02) :196-199
[9]   Incorporation of functional imaging data in the evaluation of dose distributions using the generalized concept of equivalent uniform dose [J].
Miften, MM ;
Das, SK ;
Su, M ;
Marks, LB .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1711-1721
[10]   Intensity modulated radiotherapy of non-small-cell lung cancer incorporating SPECT ventilation imaging [J].
Munawar, Iram ;
Yaremko, Brian P. ;
Craig, Jeff ;
Oliver, Michael ;
Gaede, Stewart ;
Rodrigues, George ;
Yu, Edward ;
Reid, Robert Henderson ;
Leung, Eugene ;
Urbain, Jean-Luc ;
Chen, Jeff ;
Wong, Eugene .
MEDICAL PHYSICS, 2010, 37 (04) :1863-1872