Doppler velocity and flow through the aortic isthmus in normal term neonates

被引:1
作者
Ithuralde, A [1 ]
Riggs, T [1 ]
Hussey, ME [1 ]
Weinhouse, E [1 ]
机构
[1] William Beaumont Hosp, Royal Oak, MI 48073 USA
关键词
aortic isthmus; Doppler echocardiography; continuity equation; bernoulli equation;
D O I
10.1159/000006911
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Our hypothesis was that the relationship between the internal aortic diameter and the Doppler flow velocity across the aortic isthmus could be modeled by applying the principle of conservation of mass flow. The aortic diameter decreased at the isthmus by a mean of 18% (t = 11.02, p < 0.0001), while the flow velocity increased by a mean of 44% (t = 10.09, p < 0.0001). The mean peak mass flow rate was 34.5 ml/s preisthmus and 32.9 ml/s at the isthmus with excellent correlation (r = 0.830). We conclude that the increase in Doppler velocity observed in the descending aorta can be explained by the normal narrowing observed at the aortic isthmus and application of the continuity equation for conservation of mass flow.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 11 条
[1]   ARM AND LEG BLOOD PRESSURES - ARE THEY REALLY SO DIFFERENT IN NEWBORNS [J].
COWAN, F ;
THORESEN, M ;
WALLOE, L .
EARLY HUMAN DEVELOPMENT, 1991, 26 (03) :203-211
[2]  
MORROW WR, 1986, J AM COLL CARDIOL, V8, P616
[3]   Accurate noninvasive quantitation of blood flow, cross-sectional lumen vessel area and wall shear stress by three-dimensional paraboloid modeling of magnetic resonance imaging velocity data [J].
Oyre, S ;
Ringgaard, S ;
Kozerke, S ;
Paaske, WP ;
Erlandsen, M ;
Boesiger, P ;
Pedersen, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (01) :128-134
[4]  
PARK MK, 1987, PEDIATRICS, V79, P907
[5]  
PARK MK, 1989, PEDIATRICS, V83, P240
[6]   HUMAN BLOOD-PRESSURE DETERMINATION BY SPHYGMOMANOMETRY [J].
PERLOFF, D ;
GRIM, C ;
FLACK, J ;
FROHLICH, ED ;
HILL, M ;
MCDONALD, M ;
MORGENSTERN, BZ .
CIRCULATION, 1993, 88 (05) :2460-2470
[7]   Non-invasive blood pressure measurements and aortic blood flow velocity in neonates [J].
Rahiala, E ;
Tikanoja, T .
EARLY HUMAN DEVELOPMENT, 1997, 49 (02) :107-112
[8]   NONINVASIVE DIAGNOSIS OF COARCTATION OF THE AORTA IN THE PRESENCE OF A PATENT DUCTUS-ARTERIOSUS [J].
RAMACIOTTI, C ;
CHIN, AJ .
AMERICAN HEART JOURNAL, 1993, 125 (01) :179-185
[9]   HEMODYNAMIC CONSIDERATIONS IN DEVELOPMENT OF NARROWING OF AORTA [J].
RUDOLPH, AM ;
SPITZNAS, U ;
HEYMANN, MA .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 30 (05) :514-+
[10]   INTERNAL DIAMETERS OF THE VENTRICULO-ARTERIAL JUNCTIONS AND GREAT-ARTERIES OF NORMAL INFANTS AND CHILDREN - A DATA-BASE FOR EVALUATION OF CONGENITAL CARDIAC-MALFORMATIONS [J].
VANMEURSVANWOEZIK, H ;
DEBETS, T ;
KLEIN, HW .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1989, 23 (03) :303-308