Energy cost assessment of a dairy industry wastewater treatment plant

被引:18
作者
Yapicioglu, Pelin [1 ]
Yesilnacar, Mehmet Irfan [1 ]
机构
[1] Harran Univ, Engn Fac, Environm Engn Dept, Sanliurfa, Turkey
关键词
Energy costs; Dairy industry wastewater; Dissolved air flotation; Monte Carlo simulation; Water-energy nexus; Wastewater reuse; EFFICIENCY; OPERATION; SELECTION; REMOVAL; POLICY; NEXUS;
D O I
10.1007/s10661-020-08492-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water and energy are closely interlinked during their production and consumption processes. The limited and temporary distribution of energy and water resources poses a significant environmental challenge. Industrial wastewater treatment plants are essential elements of water production and also significant energy consumers. This study proposes a methodology for energy management of a wastewater treatment plant. Specifically, it examines the impact of optimum operating conditions on energy costs for a dairy wastewater treatment plant using a dissolved air flotation process. Monte Carlo simulation was used to optimize the parameters and to determine the reuse potential of dairy effluent. Firstly, the optimum operating conditions were determined. The results revealed a maximum fat, oil, and grease removal efficiency of 97% and a chemical oxygen demand removal efficiency of 70%. The optimum conditions were pH of 8, a saturation pressure of 5 bars, and a recirculation ratio of 33%. The optimum concentrations of coagulant and flocculant that contain polyaluminum chloride and cationic polymer were 20 mg/L and 25 mg/L, respectively. The results of the simulation study gave a recirculation ratio of 26.31%, a polyaluminum chloride concentration of 42.5 mg/L, a cationic polymer concentration of 36.31 mg/L, and a saturation pressure of 4.61 bars. Finally, energy cost assessment was performed using a newly developed model which showed that the energy cost indicator of the existing process was lower than optimum operating conditions. The reuse potential of dairy effluent as cooling water was found to be 52%.
引用
收藏
页数:17
相关论文
共 45 条
  • [1] Determination of optimum conditions for dairy wastewater treatment in UAASB reactor for removal of nutrients
    Amini, Malihe
    Younesi, Habibollah
    Lorestani, Ali Akbar Zinatizadeh
    Najafpour, Ghasem
    [J]. BIORESOURCE TECHNOLOGY, 2013, 145 : 71 - 79
  • [2] Amini Malihe, 2012, International Journal of Environmental Studies, V69, P962, DOI 10.1080/00207233.2012.739428
  • [3] [Anonymous], 1998, STANDARD METHODS EXA
  • [4] [Anonymous], MOD ENV SCI ENG
  • [5] [Anonymous], 1664 EPA US OFF WAT
  • [6] Modeling an industrial dissolved air flotation tank used for separating oil from wastewater
    Behin, J.
    Bahrami, S.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2012, 59 : 1 - 8
  • [7] Buyukkamac N., 2007, 7 NATL ENV ENG C P, P502
  • [8] The relevance of the design characteristics to the optimal operation of wastewater treatment plants: Energy cost assessment
    Castellet-Viciano, Liedo
    Torregrossa, Dario
    Hernandez-Sancho, Francesc
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2018, 222 : 275 - 283
  • [9] Selection of industrial (food, drink and milk sector) wastewater treatment technologies: A multi-criteria assessment
    Castillo, A.
    Vall, P.
    Garrido-Baserba, M.
    Comas, J.
    Poch, M.
    [J]. JOURNAL OF CLEANER PRODUCTION, 2017, 143 : 180 - 190
  • [10] Chow L.S., 2007, THESIS