DGA Comparison Between Ester and Mineral Oils

被引:62
作者
Perrier, C. [1 ]
Marugan, M. [2 ]
Beroual, A. [3 ]
机构
[1] ARC Res Ctr, Alstom Grid, F-69611 Villeurbanne, France
[2] TICC Res Ctr, Alstom Grid, F-91300 Massy, France
[3] Ecole Cent Lyon, Ampere CNRS UMR 5005, F-69134 Ecully, France
关键词
Mineral and ester oils; DGA; breakdown voltage; stray gassing; POWER TRANSFORMERS;
D O I
10.1109/TDEI.2012.6311507
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports on a comparative study between mineral and various ester oils based on Dissolved Gas Analysis (DGA). Electrical (breakdown of low energy) and thermal (stray gassing) faults were realized at laboratory scale, then gas formation as well as diagnosis methods were compared. Two extraction methods, described in IEC 60567 Ed.3 and independent from partition/solubility coefficients were used: multi-cycle vacuum degassing and stripping. Three different diagnosis methods were applied: IEC gas ratios, Duval's triangle and key gases. For electrical faults and especially for low energy discharges, the same main gases (Hydrogen and Acetylene) are created in relatively same ratios, thus confirming the efficiency of key gases method for ester oils. It is also shown that classic Duval's triangle (triangle 1) is well applicable for this type of fault confirming the results reported in literature. For thermal faults and especially for stray gassing issue (low thermal faults), Ethane (associated with Hydrogen) constitutes the key gas of natural esters. The new Duval's triangles can be applied: Triangle 4 for mineral oil and Triangle 6 for ester oils. For extraction methods and in both electrical and thermal faults cases, it can be noted that results are comparable for mineral oil whereas they are slightly underestimated with stripping method for ester oils. The higher viscosity of ester could interfere with the extraction.
引用
收藏
页码:1609 / 1614
页数:6
相关论文
共 11 条
[1]  
[Anonymous], 2002, D361202 ASTM
[2]  
[Anonymous], 2005, 60567 IEC
[3]  
[Anonymous], 2008, C57104 IEEE
[4]  
[Anonymous], 2006, REC DEV DGA INT
[5]  
CIGRE, 2010, DGA NONM OILS LOAD T
[6]  
Duval M., 2009, 76 ANN INT DOBL CLIE
[7]   The Duval Triangle for Load Tap Changers, Non-Mineral Oils and Low Temperature Faults in Transformers [J].
Duval, Michel .
IEEE ELECTRICAL INSULATION MAGAZINE, 2008, 24 (06) :22-29
[8]  
IEC, 1999, 60599 IEC
[9]   Dissolved gas analysis of alternative fluids for power transformers [J].
Khan, Imad-U ;
Wang, Zhongdong ;
Cotton, Ian ;
Northcote, Susan .
IEEE ELECTRICAL INSULATION MAGAZINE, 2007, 23 (05) :5-14
[10]   Experimental Investigations on Insulating Liquids for Power Transformers: Mineral, Ester, and Silicone Oils [J].
Perrier, C. ;
Beroual, A. .
IEEE ELECTRICAL INSULATION MAGAZINE, 2009, 25 (06) :6-13