Influence of Iterative Reconstruction Algorithms on PET Image Resolution

被引:2
作者
Karpetas, G. E. [1 ]
Michail, C. M. [2 ]
Fountos, G. P. [2 ]
Valais, I. G. [2 ]
Nikolopoulos, D. [3 ]
Kandarakis, I. S. [2 ]
Panayiotakis, G. S. [1 ]
机构
[1] Univ Patras, Fac Med, Dept Med Phys, Patras 26500, Greece
[2] Technol Educ Inst Athens, Dept Biomed Engn, Radiat Phys Mat Technol & Biomed Imaging Lab, Athens 12210, Greece
[3] Technol Educ Inst Piraeus, Dept Comp Elect Engn, Athens 12244, Greece
来源
INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015) | 2015年 / 637卷
关键词
PET; MTF; image quality; iterative rcconstruction; Monte Carlo; SINGLE-CRYSTAL SCINTILLATORS; NUCLEAR-MEDICINE; LYSO-CE; PERFORMANCE; MTF;
D O I
10.1088/1742-6596/637/1/012011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the present study was to assess image quality of PET scanners through a thin layer chromatography (TLC) plane source. The source was simulated using a previously validated Monte Carlo model. The model was developed by using the GATE MC package and reconstructed images obtained with the STIR software for tomographic image reconstruction. The simulated PET scanner was the GE DiscoveryST. A plane source consisted of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrates, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF). MIT curves were estimated from transverse reconstructed images of the plane source. Images were reconstructed by the maximum likelihood estimation (MLE)-OSMAPOSL, the ordered subsets separable paraboloidal surrogate (OSSPS), the median root prior (MRP) and OSMAPOSL with quadratic prior, algorithms. OSMAPOSL reconstruction was assessed by using fixed subsets and various iterations, as well as by using various beta (hyper) parameter values. MIT values were found to increase with increasing iterations. MIT also improves by using lower beta values. The simulated PET evaluation method, based on the TLC plane source, can be useful in the resolution assessment of PEf scanners.
引用
收藏
页数:4
相关论文
共 23 条
  • [21] A comparative study of the luminescence properties of LYSO:Ce, LSO:Ce, GSO:Ce and BGO single crystal scintillators for use in medical X=ray imaging
    Valais, I.
    Michail, C.
    David, S.
    Nomicos, C. D.
    Panayiotakis, G. S.
    Kandarakis, I.
    [J]. PHYSICA MEDICA, 2008, 24 (02) : 122 - 125
  • [22] Luminescence emission properties of (Lu, Y)2SiO5:Ce (LYSO:Ce) and (Lu, Y)AlO3:Ce (LuYAP:Ce) single crystal scintillators under medical imaging conditions
    Valais, Ioannis G.
    Michail, Christos M.
    David, Stratos L.
    Konstantinidis, Anastasios
    Cavouras, Dionisis A.
    Kandarakis, Ioannis S.
    Panayiotakis, George S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (02) : 785 - 789
  • [23] Comparative Investigation of Ce3+ Doped Scintillators in a Wide Range of Photon Energies Covering X-ray CT, Nuclear Medicine and Megavoltage Radiation Therapy Portal Imaging Applications
    Valais, Ioannis G.
    Michail, Christos M.
    David, Stratos L.
    Liaparinos, Panagiotis F.
    Fountos, George P.
    Paschalis, Theodoros V.
    Kandarakis, Ioannis S.
    Panayiotakis, George S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 3 - 7