Influence of Iterative Reconstruction Algorithms on PET Image Resolution

被引:2
作者
Karpetas, G. E. [1 ]
Michail, C. M. [2 ]
Fountos, G. P. [2 ]
Valais, I. G. [2 ]
Nikolopoulos, D. [3 ]
Kandarakis, I. S. [2 ]
Panayiotakis, G. S. [1 ]
机构
[1] Univ Patras, Fac Med, Dept Med Phys, Patras 26500, Greece
[2] Technol Educ Inst Athens, Dept Biomed Engn, Radiat Phys Mat Technol & Biomed Imaging Lab, Athens 12210, Greece
[3] Technol Educ Inst Piraeus, Dept Comp Elect Engn, Athens 12244, Greece
来源
INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015) | 2015年 / 637卷
关键词
PET; MTF; image quality; iterative rcconstruction; Monte Carlo; SINGLE-CRYSTAL SCINTILLATORS; NUCLEAR-MEDICINE; LYSO-CE; PERFORMANCE; MTF;
D O I
10.1088/1742-6596/637/1/012011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the present study was to assess image quality of PET scanners through a thin layer chromatography (TLC) plane source. The source was simulated using a previously validated Monte Carlo model. The model was developed by using the GATE MC package and reconstructed images obtained with the STIR software for tomographic image reconstruction. The simulated PET scanner was the GE DiscoveryST. A plane source consisted of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrates, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF). MIT curves were estimated from transverse reconstructed images of the plane source. Images were reconstructed by the maximum likelihood estimation (MLE)-OSMAPOSL, the ordered subsets separable paraboloidal surrogate (OSSPS), the median root prior (MRP) and OSMAPOSL with quadratic prior, algorithms. OSMAPOSL reconstruction was assessed by using fixed subsets and various iterations, as well as by using various beta (hyper) parameter values. MIT values were found to increase with increasing iterations. MIT also improves by using lower beta values. The simulated PET evaluation method, based on the TLC plane source, can be useful in the resolution assessment of PEf scanners.
引用
收藏
页数:4
相关论文
共 23 条
  • [1] [Anonymous], 2007, NEMA STANDARDS PUBLI
  • [2] Determination of the presampled MTF in computed tomography
    Boone, JM
    [J]. MEDICAL PHYSICS, 2001, 28 (03) : 356 - 360
  • [3] Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
    Cheng, Ju-Chieh
    Shoghi, Kooresh
    Laforest, Richard
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1029 - 1041
  • [4] A PERFORMANCE STUDY OF 3D RECONSTRUCTION ALGORITHMS FOR POSITRON EMISSION TOMOGRAPHY
    DEFRISE, M
    GEISSBUHLER, A
    TOWNSEND, DW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 305 - 320
  • [5] Fountos G, 2009, IFMBE PROC, V25, P802, DOI 10.1007/978-3-642-03879-2_224
  • [6] A novel easy-to-use phantom for the determination of MTF in SPECT scanners
    Fountos, G. P.
    Michail, C. M.
    Zanglis, A.
    Samartzis, A.
    Martini, N.
    Koukou, V.
    Kalatzis, I.
    Kandarakis, I. S.
    [J]. MEDICAL PHYSICS, 2012, 39 (03) : 1561 - 1570
  • [7] A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY
    FUJITA, H
    TSAI, DY
    ITOH, T
    DOI, K
    MORISHITA, J
    UEDA, K
    OHTSUKA, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) : 34 - 39
  • [8] A Novel Method for the Image Quality assessment of PET Scanners by Monte Carlo simulations: Effect of the scintillator
    Karpetas, G. E.
    Michail, C. M.
    Fountos, G. P.
    Kalyvas, N. I.
    Valais, I. G.
    Kandarakis, I. S.
    Panayiotakis, G. S.
    [J]. 2ND INTERNATIONAL CONFERENCE ON MATHEMATICAL MODELING IN PHYSICAL SCIENCES 2013 (IC-MSQUARE 2013), 2014, 490
  • [9] A new PET resolution measurement method through Monte-Carlo simulations
    Karpetas, George E.
    Michail, Christos M.
    Fountos, George P.
    Kandarakis, Ioannis S.
    Panayiotakis, George S.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (09) : 967 - 976
  • [10] Karpetas GE, 2013, HELL J NUCL MED, V16, P111, DOI 10.1967/s002449910082