Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model

被引:101
|
作者
Renner, Jochen [1 ]
Gruenewald, Matthias [1 ]
Quaden, Rene [2 ]
Hanss, Robert [1 ]
Meybohm, Patrick [1 ]
Steinfath, Markus [1 ]
Scholz, Jens [1 ]
Bein, Berthold [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesia & Intens Care Med, Campus Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Cardiothorac & Vasc Surg, Campus Kiel, Germany
关键词
pneumoperitoneum; intra-abdominal pressure; intraabdominal hypertension; fluid responsiveness; preload; monitoring; pulse pressure variation; stroke volume variation; global end-diastolic volume; ABDOMINAL COMPARTMENT SYNDROME; INTRATHORACIC BLOOD-VOLUME; END-DIASTOLIC VOLUME; CRITICALLY-ILL PATIENTS; CARDIAC-OUTPUT; INTERNATIONAL-CONFERENCE; RESPIRATORY CHANGES; PERFUSION-PRESSURE; SUPERIOR PARAMETER; LOADING CONDITIONS;
D O I
10.1097/CCM.0b013e3181959864
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Dynamic variables of fluid responsiveness such as pulse pressure variation (PPV) and stroke volume variation (SVV) have been shown to reliably predict the response to fluid administration in different patient populations. The influence of increased intra-abdominal pressure (IAP) on the predictive ability of these variables is currently under debate. Therefore, the present study was designed to evaluate whether PPV and SVV are suitable for predicting fluid responsiveness during elevated IAP. Design: Prospective controlled experimental study. Setting. Animal research laboratory. Subjects. 14 anesthetized and mechanically ventilated pigs. Interventions: Pigs were studied at different experimental stages: normovolemia at baseline conditions, after induction of pneumoperitoneum (PP) by increasing IAP up to 25 mm Hg, followed by releasing PIP and performing a fluid load with 1000 cc hydroxyl-ethyl starch 6%, and finally after inducing PP again. Cardiac output, stroke volume, central venous pressure, and pulmonary artery occlusion pressure were obtained by pulmonary artery thermodilution. Additionally, global end-diastolic volume (GEDV) was measured by transpulmonary thermodilution. PPV and SVV were monitored continuously by pulse contour analysis. Measurements and Main Results: PP induced significant changes in peak airway pressure, esophageal pressure, chest wall compliance, SVV, PPV, central venous pressure, and pulmonary artery occlusion pressure independent of loading conditions. As assessed by receiver operating characteristic curve analysis, PPV, SVV, and GEDV accurately predicted fluid responsiveness before IAP was increased (area under the curve: 0.90, 0.91 and 0.91). A PPV value of >= 11.5%, a SVV value of >= 9.5%, and a GEDV value of <= 963 mL accurately predicted an increase in stroke volume >= 15%. After increasing IAP, the ability of SVV to predict fluid responsiveness was abolished, whereas it was preserved with both PPV and GEDV, although the threshold value for PPV dramatically increased up to >= 20.5%. Conclusions. In this animal model PPV and GEDV proved to be sensitive and specific predictors of fluid responsiveness even during increased IAP. (Crit Care Med 2009; 37:650-658)
引用
收藏
页码:650 / 658
页数:9
相关论文
共 50 条
  • [41] Assessment of fluid responsiveness during increased intra-abdominal pressure: keep the indices, but change the thresholds
    Tavernier, Benoit
    Robin, Emmanuel
    CRITICAL CARE, 2011, 15 (02):
  • [42] Assessment of fluid responsiveness during increased intra-abdominal pressure: keep the indices, but change the thresholds
    Benoit Tavernier
    Emmanuel Robin
    Critical Care, 15
  • [43] Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study
    Fritz Daudel
    David Tüller
    Stefanie Krähenbühl
    Stephan M Jakob
    Jukka Takala
    Critical Care, 14
  • [44] Saline volume in transvesical intra-abdominal pressure measurement: enough is enough
    De Waele, J
    Pletinckx, P
    Blot, S
    Hoste, E
    INTENSIVE CARE MEDICINE, 2006, 32 (03) : 455 - 459
  • [45] Saline volume in transvesical intra-abdominal pressure measurement: enough is enough
    J. De Waele
    P. Pletinckx
    S. Blot
    E. Hoste
    Intensive Care Medicine, 2006, 32 : 455 - 459
  • [46] INFLUENCE OF INTRA-ABDOMINAL PRESSURE ON THE BASIC VITAL FUNCTIONS AND FINAL TREATMENT OUTCOME
    Svorcan, Petar
    Stojanovic, Maja
    Stevanovic, Predrag
    Karamarkovic, Aleksandar
    Jankovic, Radmilo
    Ladjevic, Nebojsa
    ACTA CLINICA CROATICA, 2016, 55 (02) : 316 - 322
  • [47] Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation
    Suehiro, K.
    Rinka, H.
    Ishikawa, J.
    Fuke, A.
    Arimoto, H.
    Miyaichi, T.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) : 767 - 772
  • [48] THE ROLE OF FEMORAL VENOUS PRESSURE AND FEMORAL VENOUS OXYGEN SATURATION IN THE SETTING OF INTRA-ABDOMINAL HYPERTENSION: A PIG MODEL
    Regli, Adrian
    De Keulenaer, Bart L.
    Hockings, Lisen E.
    Musk, Gabrielle C.
    Roberts, Brigit
    van Heerden, Peter V.
    SHOCK, 2011, 35 (04): : 422 - 427
  • [49] Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review
    Chen, Jiaxin
    Zhao, Shuhua
    Zhu, Qianqian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (02) : 379 - 387
  • [50] Predictor of fluid responsiveness in the 'grey zone': augmented pulse pressure variation through a temporary increase in tidal volume
    Min, J. J.
    Gil, N. -S.
    Lee, J. -H.
    Ryu, D. K.
    Kim, C. S.
    Lee, S. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 (01) : 50 - 56