Microelectrode accuracy in deep brain stimulation surgery

被引:10
作者
Brahimaj, Bledi [1 ]
Kochanski, Ryan B. [1 ]
Sani, Sepehr [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Neurosurg, 1725 W Harrison St,Suite 855, Chicago, IL 60612 USA
关键词
Stereotactic targeting; Microelectrode recording; Deep brain stimulation; Accuracy; Intraoperative imaging; Intraoperative CT; SUBTHALAMIC NUCLEUS; PARKINSONS-DISEASE; IMAGE FUSION; DBS SURGERY; ELECTRODES; MRI; CT; LOCALIZATION; DYSTONIA; LOCATION;
D O I
10.1016/j.jocn.2018.01.020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Microelectrode recording (MER) provides vital neurophysiological information about target nuclei during deep brain stimulation (DBS). There have been extensive studies looking at the accuracy of DBS lead placement; however, to date, no large series have assessed the accuracy of the microelectrode. In this study, we report the accuracy of microelectrode tip placement in comparison to preoperatively planned radiographic target. Patients who underwent DBS with MER from 2014 to 2016 were included in the study. At the authors' institution, intra-operative CT (iCT) is routinely performed after the first microelectrode track to confirm tip accuracy. Retrospective analysis of microelectrode track error was calculated between the planned trajectory and the microelectrode tip. The radial error was calculated on the same axial plane using the Euclidian distance formula, and multivariate analysis was performed to ascertain any directional bias of error. A total of 227 microelectrode tracks were analyzed, (150 STN, 50 ViM, 27 GPi) yielding a total radial error of 1.2 mm +/- 0.2 SEM across all targets. Analysis of vector error distribution revealed lack of directional bias. MER is an accurate electrophysiological representation of the planned target. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 61
页数:4
相关论文
共 22 条
[1]  
[Anonymous], PUBMED J
[2]   Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT) [J].
Barnaure, I. ;
Pollak, P. ;
Momjian, S. ;
Horvath, J. ;
Lovblad, K. O. ;
Boex, C. ;
Remuinan, J. ;
Burkhard, P. ;
Vargas, M. I. .
NEURORADIOLOGY, 2015, 57 (09) :903-908
[3]   LONG-TERM SUPPRESSION OF TREMOR BY CHRONIC STIMULATION OF THE VENTRAL INTERMEDIATE THALAMIC NUCLEUS [J].
BENABID, AL ;
POLLAK, P ;
GERVASON, C ;
HOFFMANN, D ;
GAO, DM ;
HOMMEL, M ;
PERRET, JE ;
DEROUGEMONT, J .
LANCET, 1991, 337 (8738) :403-406
[4]   Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording Clinical article [J].
Burchiel, Kim J. ;
McCartney, Shirley ;
Lee, Albert ;
Raslan, Ahmed M. .
JOURNAL OF NEUROSURGERY, 2013, 119 (02) :301-306
[5]  
Burchiel KJ, 1999, NEUROSURGERY, V45, P1375, DOI 10.1097/00006123-199912000-00024
[6]   Deep Brain Stimulation for Intractable Psychiatric Disorders [J].
Goodman, Wayne K. ;
Alterman, Ron L. .
ANNUAL REVIEW OF MEDICINE, VOL 63, 2012, 63 :511-524
[7]   A Quantitative Assessment of the Accuracy and Reliability of O-Arm Images for Deep Brain Stimulation Surgery [J].
Holloway, Kathryn ;
Docef, Alen .
NEUROSURGERY, 2013, 72 :47-57
[8]   Deep brain stimulation of the subthalamic nucleus: anatomical, neurophysiological, and outcome correlations with the effects of stimulation [J].
Lanotte, MM ;
Rizzone, M ;
Bergamasco, B ;
Faccani, G ;
Melcarne, A ;
Lopiano, L .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2002, 72 (01) :53-58
[9]   Validation of CT-MRI Fusion for Intraoperative Assessment of Stereotactic Accuracy in DBS Surgery [J].
Mirzadeh, Zaman ;
Chapple, Kristina ;
Lambert, Meg ;
Dhall, Rohit ;
Ponce, Francisco A. .
MOVEMENT DISORDERS, 2014, 29 (14) :1788-1795
[10]   Microelectrode targeting of the subthalamic nucleus for deep brain stimulation surgery [J].
Montgomery, Erwin B., Jr. .