Numerical investigation of indoor air quality in a floor heated room with different air change rates

被引:17
|
作者
Mutlu, Mustafa [1 ]
机构
[1] Bursa Uludag Univ, Vocat Sch Yenisehir Ibrahim Orhan, Air Conditioning & Refrigerat Tech Program, TR-16900 Bursa, Turkey
关键词
particle concentration; indoor air quality; floor heating; air change rates; PARTICLE DISPERSION; THERMAL COMFORT; VENTILATED ROOMS; HEATING-SYSTEMS; DEPOSITION; ENVIRONMENTS; SIMULATION; RADIATOR; CFD;
D O I
10.1007/s12273-020-0683-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nowadays, indoor air quality is no longer considered as providing thermal comfort. The pollutant concentration in the ambient air (CO2, O-3, particulate matter, etc.) is an essential factor affecting both indoor air quality and human health negatively. Particle motion in a room is affected by air movements caused by heating systems and infiltration and needs to be examined. Therefore, this study aims to explain how infiltration rates in a room with floor heating affect both thermal conditions and particularly the particle concentration and distribution. In this study, the discrete phase model (DPM) was used for particle tracking using commercial software ANSYS FLUENT. It was assumed that drag, lift, thermophoretic and Brownian forces were affecting particle motions. It was seen that air change rates influence both thermal comfort and energy consumption as well as particle distribution significantly. It was found that increasing air change rates causes a rise in particle concentration in all sizes of particles, specifically for the lower parts of the room (below 0.75 m from the floor). It is recommended to place air purifying devices where the outdoor sourced air infiltrates the room. Additionally, an index that contains thermal comfort and particle concentration together was defined and its distribution in the room was examined. It is found that the air change rate is a critical factor in obtaining desired indoor air quality, but outdoor air conditions may worsen the indoor quality due to air pollution. As the air change rate significantly alters the airflow in the room, both thermal comfort perception and particle concentrations vary considerably.
引用
收藏
页码:1063 / 1075
页数:13
相关论文
共 50 条
  • [21] Indoor air quality investigation on commercial aircraft
    Lee, SC
    Poon, CS
    Li, XD
    Luk, F
    INDOOR AIR, 1999, 9 (03) : 180 - 187
  • [22] Investigation on indoor air quality and air cleaner testing in Taiwan district
    Yuan, CS
    Wu, YJ
    Lo, CC
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 10 - 15
  • [23] Fresh air rate in air conditioning buildings and indoor air quality
    Pei Qing-qing
    Liu Wei
    Zhou Zhi-ming
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 95 - 98
  • [24] Numerical and Experimental Study on Indoor Air Distribution and Quality
    Gao, Zhen
    Jiang, Yun
    Ouyang, Kuangzhong
    Hu, Haowei
    Zhang, Siwei
    Ma, Jinwei
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017), 2017, 129 : 770 - 775
  • [25] Indoor Air Quality Evaluation of Isolation Room for Hospital in Thailand
    Tungjai, A.
    Kubaha, K.
    2017 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2017, 138 : 858 - 863
  • [26] Investigation of indoor air quality and indoor/outdoor relationship in three different microenvironments of central part of India
    Lawrence, AJ
    Taneja, A
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 797 - 801
  • [27] Investigation of Indoor Air Quality in the Underground Shopping Mall
    Yang, Jia
    Wu, Xiangsheng
    Chan, K. T.
    Yang, Xiaofeng
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [28] Investigation on Indoor Air Quality in Tianjin Residential Buildings
    Sun, Yuexia
    Cheng, Rongsai
    Hou, Jing
    Song, Yangrui
    Luo, Shugang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3811 - 3815
  • [29] Investigation of indoor air quality at urban schools in Qatar
    Abdel-Salam, Mahmoud M. M.
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (02) : 278 - 288
  • [30] A case study investigation of indoor air quality in UK Passivhaus dwellings
    McGill, Grainne
    Qin, Menghao
    Oyedele, Lukumon
    6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 : 190 - 199