HeartWare Ventricular Assist Device Cannula Position and Hemocompatibility-Related Adverse Events

被引:6
|
作者
Imamura, Teruhiko [1 ,2 ]
Narang, Nikhil [3 ]
Nitta, Daisuke [1 ]
Fujino, Takeo [1 ]
Nguyen, Ann [1 ]
Chung, Ben [1 ]
Holzhauser, Luise [1 ]
Kim, Gene [1 ]
Raikhelkar, Jayant [4 ]
Kalantari, Sara [1 ]
Smith, Bryan [1 ]
Juricek, Colleen [5 ]
Rodgers, Daniel [1 ]
Ota, Takeyoshi [5 ]
Song, Tae [5 ]
Jeevanandam, Valluvan [5 ]
Sayer, Gabriel [4 ]
Uriel, Nir [4 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Toyama, Dept Med 2, Toyama, Japan
[3] Advocate Christ Med Ctr, Advocate Heart Inst, Oak Lawn, IL USA
[4] Columbia Univ, Div Cardiol, Irving Med Ctr, New York, NY USA
[5] Univ Chicago, Med Ctr, Dept Surg, Chicago, IL 60637 USA
来源
ANNALS OF THORACIC SURGERY | 2020年 / 110卷 / 03期
关键词
PUMP; GUIDELINES; SUPPORT; SOCIETY; RISK;
D O I
10.1016/j.athoracsur.2019.12.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. HeartWare ventricular assist device (HVAD) cannula position is associated with hemodynamics and heart failure readmissions. However, its impact on hemocompatibility-related adverse events (HRAEs) remains uncertain. Methods. HVAD patients were followed for 1 year after index hospitalization, when cannula coronal angle was quantified from chest x-ray film. Invasive right heart catheterization and transthoracic echocardiography were performed. One-year occurrences of each HRAE were compared between those with and without a cannula coronal angle of greater than 65 degrees. Results. Among 63 HVAD patients (median age 60 years, 63% male), 10 (16%) had a cannula coronal angle greater than 65 degrees. The wide-angle group had elevated intracardiac pressures and lower pulmonary artery pulsatility index (P <.05). They also had reduced right ventricular function by echocardiography. Freedom from HRAEs tended to be lower in the wide-angle group (24% vs 62%; P = .11). The rate of gastrointestinal bleeding was significantly higher in the greater than 65 degrees group (0.90 events/year vs 0.40 events/year; P = .013). The rates of stroke and pump thrombosis were statistically comparable irrespective of cannula angle (P >.05). Conclusions. HVAD cannula coronal angle was associated with reduced right ventricular function and HRAEs. Prospective studies evaluating surgical techniques to ensure optimal device positioning and its effects on HRAEs are warranted. (C) 2020 by The Society of Thoracic Surgeons.
引用
收藏
页码:911 / 917
页数:7
相关论文
共 50 条
  • [1] Aortic Insufficiency and Hemocompatibility-related Adverse Events in Patients with Left Ventricular Assist Devices
    Imamura, Teruhiko
    Kim, Gene
    Nitta, Daisuke
    Fujino, Takeo
    Smith, Bryan
    Kalantari, Sara
    Ann Nguyen
    Narang, Nikhil
    Holzhauser, Luise
    Grinstein, Jonathan
    Juricek, Colleen
    Rodgers, Daniel
    Song, Tae
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    JOURNAL OF CARDIAC FAILURE, 2019, 25 (10) : 787 - 794
  • [2] Angiopoietin-2 and hemocompatibility-related adverse events during percutaneous left ventricular assist device supports
    Imamura, Teruhiko
    Nakamura, Makiko
    Yokoyama, Shigeki
    Doi, Toshio
    Fukahara, Kazuaki
    Kinugawa, Koichiro
    HEALTH SCIENCE REPORTS, 2020, 3 (04)
  • [3] Comparison in Hemocompatibility-Related Adverse Events in Patients Supported With Left Ventricular Assist Device Between Japan and United States
    Imamura, Teruhiko
    Ono, Minoru
    Fukushima, Norihide
    Kinugawa, Koichiro
    Shiose, Akira
    Marsui, Yoshiro
    Yamazaki, Kenji
    Saiki, Yoshikatsu
    Usui, Akihiko
    Niinami, Hiroshi
    Matsumiya, Goro
    Arai, Hirokuni
    Sawa, Yoshiki
    Kim, Gene
    Sayer, Gabriel
    Naka, Yoshifumi
    Jeevanandam, Valluvan
    Uriel, Nir
    CIRCULATION, 2018, 138
  • [4] Implication of Preoperative Existence of Atrial Fibrillation on Hemocompatibility-Related Adverse Events During Left Ventricular Assist Device Support
    Imamura, Teruhiko
    Kinugawa, Koichiro
    Ono, Minoru
    Kinoshita, Osamu
    Fukushima, Norihide
    Shiose, Akira
    Matsui, Yoshiro
    Yamazaki, Kenji
    Saiki, Yoshikatsu
    Usui, Akihiko
    Niinami, Hiroshi
    Matsumiya, Goro
    Arai, Hirokuni
    Sawa, Yoshiki
    CIRCULATION JOURNAL, 2019, 83 (06) : 1286 - +
  • [5] Hemocompatibility-related Adverse Events Following HeartMate II Left Ventricular Assist Device Implantation between Japan and United States
    Imamura, Teruhiko
    Ono, Minoru
    Kinugawa, Koichiro
    Fukushima, Norihide
    Shiose, Akira
    Matsui, Yoshiro
    Yamazaki, Kenji
    Saiki, Yoshikatsu
    Usui, Akihiko
    Niinami, Hiroshi
    Matsumiya, Goro
    Arai, Hirokuni
    Sawa, Yoshiki
    Uriel, Nir
    MEDICINA-LITHUANIA, 2020, 56 (03):
  • [6] Assessment of Platelet Response to Aspirin Therapy and Hemocompatibility-Related Adverse Events in HeartMate 3 Left Ventricular Assist Device Recipients
    Schloeglhofer, T.
    Al Asadi, H.
    Abart, T.
    Schwarz, C.
    Schima, H.
    Riebandt, J.
    Marko, C.
    Wiedemann, D.
    Messner, B.
    Zimpfer, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S282 - S282
  • [7] Omega-3 Therapy is Associated With Reduced Hemocompatibility-Related Adverse Events Following Left Ventricular Assist Device Implantation.
    Imamura, Teruhiko
    Nguyen, Ann
    Rodgers, Daniel
    Kim, Gene
    Raikhelkar, Jayant
    Sarswat, Nitasha
    Kalantari, Sara
    Smith, Bryan
    Chung, Ben
    Narang, Nikhil
    Juricek, Colleen
    Song, Tae
    Takeyoshi, Ota
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    CIRCULATION, 2018, 138
  • [8] Comparison of Hemocompatibility-Related Adverse Events in HVAD versus HeartMate II Device
    Mehta, P.
    Imamura, T.
    Belkin, M.
    Sarswat, N.
    Kim, G.
    Raikhelkar, J.
    Kalantari, S.
    Chung, B.
    Nguyen, A.
    Song, T.
    LaBuhn, C.
    Rodgers, D.
    Ota, T.
    Jeevanandam, V.
    Sayer, G.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S265 - S265
  • [9] Pulmonary Effective Arterial Elastance and Pulmonary Artery Capacitance after Left Ventricular Assist Device Implantation is Associated with Hemocompatibility-Related Adverse Events
    Nitta, D.
    Imamura, T.
    Fujino, T.
    Nguyen, A.
    Chung, B.
    Rodgers, D.
    Raikhelkar, J.
    Smith, B.
    Holzhauser, L.
    Narang, N.
    Ebong, I.
    Juricek, C.
    Jeevanandam, V.
    Kim, G.
    Sayer, G.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S168 - S168
  • [10] Omega-3 and hemocompatibility-related adverse events
    Imamura, Teruhiko
    Nguyen, Ann
    Rodgers, Daniel
    Kim, Gene
    Raikhelkar, Jayant
    Kalantari, Sara
    Narang, Nikhil
    Juricek, Colleen
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (02) : 405 - 412