Radiation background and beam quality in Secondary X-ray Imaging for human angiography with Au as contrast agent

被引:3
|
作者
Csonka, PL [1 ]
机构
[1] Univ Oregon, Inst Theoret Sci, Eugene, OR 97403 USA
关键词
X-ray Imaging; angiography; fluorescence imaging; medical imaging; wigglers;
D O I
10.1016/j.nima.2005.09.051
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A calculation is carried out to assess the capabilities of Secondary X-ray Imaging (SXI). Human angiography is used as an example. An originally well focused primary photon pencil beam is rastered through the target (the human heart) in two dimensions. The signal consists of fluorescent photons from a contrast agent, registered by a wide angle (of order pi steradians) detector. The primary photons may be significantly more energetic than the signal photons. The last two features result in clearer images and a reduction of shadowing by obstructions inside the body. Sharp imaging is compatible with locally quantitative measurements, and with pixel-by-pixel elemental analysis. The detector need not be position sensitive. Most primary photons will be (predominantly Compton) scattered before they reach the target, the scattered photons form a broad halo around the unscattered primary beam, which remains sharp and well focused. To discriminate against scattered background, the photons have to pass through a position/momentum selector, a W-Hf absorber shield, and a time window. The calculation gives the approximate energy spectrum for the scattered photons generated, for the photons passing through the position/momentum selector, and for those arriving at the far side of the absorber shield.. the last two evaluated for various time windows in the 1000-167ps range. The surviving background will cause relative image intensity fluctuations of the order of a percent. The primary beam intensity required for SXI is comparable or less than the intensity needed for the usual K-edge subtraction (KES) imaging process. However, for SXI the primary photon energy spread may be one or two orders hip-her than needed for KES, thus relaxing the requirements on the primary photon source. If an undulator is used, monochromatization may not be needed. That further reduces cost and demands on the photon source, which may be a small low energy electron ring. To realize the full potential of the method (beyond that stated above), would require a new type of detector. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:589 / 606
页数:18
相关论文
共 50 条
  • [1] Secondary X-ray imaging: an alternative approach to angiography and other applications
    Csonka, PL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (1-2) : 306 - 319
  • [2] Power Doppler, X-ray contrast angiography and morphological imaging of the human placenta
    Gudmundsson, S
    Marsal, J
    Dubiel, M
    Maly, P
    Marsal, K
    Laurini, R
    PRENATAL AND NEONATAL MEDICINE, 2000, 5 (01): : 27 - 34
  • [3] X-ray phase contrast angiography using CO2 as contrast agent
    Lundstrom, Ulf
    Larsson, Daniel H.
    Takman, Per A. C.
    Scott, Lena
    Burvall, Anna
    Hertz, Hans M.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [4] Phase contrast X-ray imaging
    Weon, Byung Mook
    Je, Jung Ho
    Hwu, Yeukuang
    Margaritondo, Giorgio
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2006, 3 (2-3) : 280 - 297
  • [5] Phase contrast X-ray imaging
    Biomedical Imaging Center, Department of Materials Science and Engineering, Pohang University of Science and Technology, Pohang, 790-784, Korea, Republic of
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    Int. J. Nanotechnol., 2006, 2-3 (280-297): : 280 - 297
  • [6] Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle
    Ahn, Sungsook
    Jung, Sung Yong
    Lee, Jin Pyung
    Lee, Sang Joon
    CONTRAST MEDIA & MOLECULAR IMAGING, 2011, 6 (06) : 437 - 448
  • [7] Laser-produced Au nanoparticles as X-ray contrast agents for diagnostic imaging
    Torrisi, L.
    Restuccia, N.
    Cuzzocrea, S.
    Paterniti, I.
    Ielo, I.
    Pergolizzi, S.
    Cutroneo, M.
    Kovacik, L.
    GOLD BULLETIN, 2017, 50 (01) : 51 - 60
  • [8] Laser-produced Au nanoparticles as X-ray contrast agents for diagnostic imaging
    L. Torrisi
    N. Restuccia
    S. Cuzzocrea
    I. Paterniti
    I. Ielo
    S. Pergolizzi
    M. Cutroneo
    L. Kovacik
    Gold Bulletin, 2017, 50 : 51 - 60
  • [9] Area x-ray beam equalization for digital angiography
    Molloi, S
    Tang, J
    Mather, T
    Zhou, YF
    MEDICAL PHYSICS, 1999, 26 (12) : 2684 - 2692
  • [10] Tomographic imaging of microvasculature with a purpose-designed, polymeric X-ray contrast agent
    Kuo, Willy
    Le, Ngoc An
    Spingler, Bernhard
    Schulz, Georg
    Muller, Bert
    Kurtcuoglu, Vartan
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242