A Comprehensive Evaluation of Rhythm Monitoring Strategies for the Detection of Atrial Fibrillation Recurrence Insights From 647 Continuously Monitored Patients and Implications for Monitoring After Therapeutic Interventions

被引:158
作者
Charitos, Efstratios I. [1 ]
Stierle, Ulrich [1 ]
Ziegler, Paul D. [2 ]
Baldewig, Malte [1 ]
Robinson, Derek R. [3 ]
Sievers, Hans-Hinrich [1 ]
Hanke, Thorsten [1 ]
机构
[1] Med Univ Lubeck, Dept Cardiac & Thorac Vasc Surg, D-23568 Lubeck, Germany
[2] Medtronic Inc, Minneapolis, MN USA
[3] Univ Sussex, Sch Math & Phys Sci, Dept Math, Brighton, E Sussex, England
关键词
atrial fibrillation; atrial fibrillation arrhythmia; rhythm monitoring; rhythm recorders; ELECTRONIC DEVICES CIEDS; EXPERT CONSENSUS; ARRHYTHMIA RECURRENCES; IMPLANTABLE DEVICES; CATHETER ABLATION; FOLLOW-UP; TACHYARRHYTHMIAS; PERSONNEL; EVENTS; STROKE;
D O I
10.1161/CIRCULATIONAHA.112.098079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Intermittent rhythm monitoring (IRM) to detect atrial fibrillation (AF) recurrence is employed to evaluate the success of therapeutic interventions. In a large population of patients with continuous monitoring (CM), we investigated the sensitivity of various frequencies and durations of IRM strategies on the detection of AF recurrence, the dynamics behind AF recurrence detection, and we describe measures to evaluate temporal AF recurrence. Methods and Results-Rhythm histories of 647 patients (mean AF burden, 0.12 +/- 0.22; median, 0.014; 687 patient-years) with implantable CM devices were reconstructed and analyzed. With the use of computationally intensive simulation, the sensitivity of IRM of various frequencies and durations on the identification of AF recurrence was evaluated. Prolonged-duration IRM was superior to shorter IRM (P<0.0001). However, even with aggressive IRM strategies, AF recurrence was not detected in a great proportion of patients. The temporal AF burden aggregation (AF density) was directly related to IRM sensitivity (P<0.0001). Even at similar AF burdens, patients with high-density AF required higher-frequency or prolonged-duration IRM to achieve the same sensitivity as in low-density AF (P<0.0001). Patients with high-density, low-burden AF benefit the most from CM for detection of AF recurrence. Conclusions-IRM follow-up is significantly inferior to CM. IRM strategies will not identify AF recurrence in a great proportion of patients at risk. Temporal AF characteristics play a significant role in AF recurrence detection with the use of IRM. For the scientific, evidence-based evaluation of AF treatments, CM should be strongly recommended. Prospective studies are required to evaluate whether CM to guide clinical management can also improve patient outcomes.
引用
收藏
页码:806 / 814
页数:9
相关论文
共 21 条
[1]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Lesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koonlawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
EUROPACE, 2007, 9 (06) :335-379
[2]   Temporal relationship of atrial tachyarrhythmias, cerebrovascular events, and systemic emboli based on stored device data: A subgroup analysis of TRENDS [J].
Daoud, Emile G. ;
Glotzer, Taya V. ;
Wyse, D. George ;
Ezekowitz, Michael D. ;
Hilker, Christopher ;
Koehler, Jodi ;
Ziegler, Paul D. .
HEART RHYTHM, 2011, 8 (09) :1416-1423
[3]   ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs) [J].
Dubner, Sergio ;
Auricchio, Angelo ;
Steinberg, Jonathan S. ;
Vardas, Panos ;
Stone, Peter ;
Brugada, Josep ;
Piotrowicz, Ryszard ;
Hayes, David L. ;
Kirchhof, Paulus ;
Breithardt, Guenter ;
Zareba, Wojciech ;
Schuger, Claudio ;
Aktas, Mehmet K. ;
Chudzik, Michal ;
Mittal, Suneet ;
Varma, Niraj .
EUROPACE, 2012, 14 (02) :278-293
[4]   Long-term monitoring after surgical ablation for atrial fibrillation: How much is enough? [J].
Edgerton, James R. ;
Mahoney, Cecile ;
Mack, Michael J. ;
Roper, Karen ;
Herbert, Morley A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (01) :162-165
[5]   The Relationship Between Daily Atrial Tachyarrhythmia Burden From Implantable Device Diagnostics and Stroke Risk The TRENDS Study [J].
Glotzer, Taya V. ;
Daoud, Emile G. ;
Wyse, D. George ;
Singer, Daniel E. ;
Ezekowitz, Michael D. ;
Hilker, Christopher ;
Miller, Clayton ;
Qi, Dongfeng ;
Ziegler, Paul D. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (05) :474-480
[6]   Twenty-Four-Hour Holter Monitor Follow-Up Does Not Provide Accurate Heart Rhythm Status After Surgical Atrial Fibrillation Ablation Therapy Up to 12 Months Experience With a Novel Permanently Implantable Heart Rhythm Monitor Device [J].
Hanke, Thorsten ;
Charitos, Efstratios I. ;
Stierle, Ulrich ;
Karluss, Antje ;
Kraatz, Ernst ;
Graf, Bernhard ;
Hagemann, Axel ;
Misfeld, Martin ;
Sievers, Hans H. .
CIRCULATION, 2009, 120 (11) :S177-S184
[7]   Stroke with intermittent atrial fibrillation: Incidence and predictors during aspirin therapy [J].
Hart, RG ;
Pearce, LA ;
Rothbart, RM ;
McAnulty, JH ;
Asinger, RW ;
Halperin, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (01) :183-187
[8]   Subclinical Atrial Fibrillation and the Risk of Stroke [J].
Healey, Jeff S. ;
Connolly, Stuart J. ;
Gold, Michael R. ;
Israel, Carsten W. ;
Van Gelder, Isabelle C. ;
Capucci, Alessandro ;
Lau, C. P. ;
Fain, Eric ;
Yang, Sean ;
Bailleul, Christophe ;
Morillo, Carlos A. ;
Carlson, Mark ;
Themeles, Ellison ;
Kaufman, Elizabeth S. ;
Hohnloser, Stefan H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (02) :120-129
[9]   Perception of atrial fibrillation before and after radiofrequency catheter ablation - Relevance of asymptomatic arrhythmia recurrence [J].
Hindricks, G ;
Piorkowski, C ;
Tanner, H ;
Kobza, R ;
Gerds-Li, JH ;
Carbucicchio, C ;
Kottkamp, H .
CIRCULATION, 2005, 112 (03) :307-313
[10]   Performance of a New Leadless Implantable Cardiac Monitor in Detecting and Quantifying Atrial Fibrillation Results of the XPECT Trial [J].
Hindricks, Gerhard ;
Pokushalov, Evgueny ;
Urban, Lubos ;
Taborsky, Milos ;
Kuck, Karl-Heinz ;
Lebedev, Dmitry ;
Rieger, Guido ;
Puererfellner, Helmut .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (02) :141-U44