Refrigerated storage improves the stability of the complete blood cell count and automated differential

被引:1
|
作者
Wood, BL [1 ]
Andrews, J [1 ]
Miller, S [1 ]
Sabath, DE [1 ]
机构
[1] Univ Washington, Dept Lab Med 357110, Seattle, WA 98195 USA
关键词
hematology; automated; differential; CBC count; refrigeration;
D O I
暂无
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
A CBC count was performed on 113 random patient and 21 control specimens before and after 24-hour room temperature (RT) storage; 98 random patient and 20 control specimens also were analyzed before and after 24 hour 4 degrees C storage. The Cell-Dyn 3500 (Abbott Laboratories, Abbott Park, IL) was used for analysis. RT storage showed a decline in WBC count using the optical but not the impedance method, resulting in a large number of WBC flags. Art increase in mean corpuscular volume also was seen for patient specimens. The automated WBC differential showed a decrease in the percentage of neutrophils and an increase in the percentage of lymphocytes, owing primarily, to neutrophil degeneration These changes also were seen in the manual differential to a similar degree. Storage of specimens at 4 degrees C largely prevented all of these changes. Theimplementation of refrigerated specimen storage is a simple, inexpensive method to improve the accuracy of CBC results for aged specimens on automated hematology analyzers.
引用
收藏
页码:687 / 695
页数:9
相关论文
共 50 条
  • [1] Refrigerated storage decreases the white blood cell count and influences the stability of automated differential on the Sysmex SE-9000
    Choi, JW
    Pai, SH
    HAEMATOLOGIA, 2002, 32 (04) : 483 - 486
  • [2] Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature
    Gulati, GL
    Hyland, LJ
    Kocher, W
    Schwarting, R
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2002, 126 (03) : 336 - 342
  • [3] The stability of sample storage for complete blood count (CBC) toward the blood cell morphology
    Rahmnitarini, Arie
    Hernaningsih, Yetti
    Indrasari, Yulia Nadar
    BALI MEDICAL JOURNAL, 2019, 8 (02) : 391 - 395
  • [4] Complete Blood Count or Complete Blood Count with Differential: What's the Difference?
    Agrawal, Deepak
    Sarode, Ravi
    AMERICAN JOURNAL OF MEDICINE, 2017, 130 (08): : 915 - 916
  • [5] Effects of Storage Conditions on Complete Blood Cell Count Parameters
    Turhan, Turan
    Sezer, Sevilay
    Yucel, Cigdem
    Koca, Yuksel
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2011, 36 (02): : 165 - 174
  • [6] STABILITY OF COMPLETE BLOOD CELL COUNT (CBC) PARAMETERS AT ROOM TEMPERATURE AND REFRIGERATED USING XN SYSMEX HEMATOLOGICAL ANALYSER.
    Penteado, Rosana
    Junior, Erivaldo
    Barroso, Rodrigo
    Suganuma, Liliana
    Villarinho, Andrea
    Mendes, Claudio
    Monteiro, Camila
    Costa, Heloise
    Velloso, Elvira
    Guerra, Joao
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 142 - 142
  • [7] An automated differential blood count system
    Ongun, G
    Halici, U
    Leblebicioglu, K
    Atalay, V
    Beksac, M
    Beksac, S
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2583 - 2586
  • [8] Effects of varying storage time and temperature on stability of complete blood count measurements
    O'Donnoghue, JM
    Strong, MA
    Detolla, LJ
    CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 1998, 37 (06): : 52 - 54
  • [9] Possibility of myelodysplastic syndromes screening using a complete blood automated cell count
    Rocco, Vincenzo
    Maconi, Mariacaterina
    Gioia, Maria
    Silvestri, Maria Grazia
    Tanca, Donatella
    Catalano, Teodora
    Avino, Daniela
    Di Palma, Anna
    Rovetti, Adele
    Danise, Paolo
    LEUKEMIA RESEARCH, 2011, 35 (12) : 1623 - 1627
  • [10] Stability of complete blood count parameters depends on the storage temperature, storage time, transport position and selected stability criterion
    Kayadibi, Huseyin
    Acar, Ismail Aytac
    Cam, Samet
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (06): : 470 - 478