An algorithm for 4D CT image sorting using spatial continuity

被引:2
作者
Li, Chen [1 ]
Liu, Jie [1 ]
机构
[1] Beijing Jiaotong Univ, Dept Biomed Engn, Beijing 100044, Peoples R China
基金
中国国家自然科学基金;
关键词
4D CT; image sorting; spatial continuity; RESPIRATORY MOTION; ARTIFACTS;
D O I
10.3233/XST-130381
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
4D CT, which could locate the position of the movement of the tumor in the entire respiratory cycle and reduce image artifacts effectively, has been widely used in making radiation therapy of tumors. The current 4D CT methods required external surrogates of respiratory motion obtained from extra instruments. However, respiratory signals recorded by these external makers may not always accurately represent the internal tumor and organ movements, especially when irregular breathing patterns happened. In this paper we have proposed a novel automatic 4D CT sorting algorithm that performs without these external surrogates. The sorting algorithm requires collecting the image data with a cine scan protocol. Beginning with the first couch position, images from the adjacent couch position are selected out according to spatial continuity. The process is continued until images from all couch positions are sorted and the entire 3D volume is produced. The algorithm is verified by respiratory phantom image data and clinical image data. The primary test results show that the 4D CT images created by our algorithm have eliminated the motion artifacts effectively and clearly demonstrated the movement of tumor and organ in the breath period.
引用
收藏
页码:323 / 333
页数:11
相关论文
共 13 条
[1]   Correction of image artifacts from treatment couch in cone-beam CT from kV on-board imaging [J].
Ali, Imad ;
Ahmad, Salahuddin ;
Alsbou, Nesreen ;
Lovelock, Dale-Michael ;
Kriminski, Sergey ;
Amols, Howard .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (03) :321-332
[2]   Correlation and support vector machine based motion artifacts mitigation in 3D computer tomography [J].
Bhowmik, Ujjal Kumar ;
Adhami, Reza R. .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2012, 20 (02) :141-160
[3]   A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol [J].
Carnes, Greg ;
Gaede, Stewart ;
Yu, Edward ;
Van Dyk, Jake ;
Battista, Jerry ;
Lee, Ting-Yim .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :2049-2066
[4]   Artifacts in computed tomography scanning of moving objects [J].
Chen, GTY ;
Kung, JH ;
Beaudette, KP .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :19-26
[5]   Absolute alignment of breathing states using image similarity derivatives [J].
Eck, K ;
Bredno, J ;
Stehle, T .
MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 :79-86
[6]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067
[7]   An algorithm for automatic determination of the respiratory phases in four-dimensional computed tomography [J].
Kleshneva, T. ;
Muzik, J. ;
Alber, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (16) :N269-N276
[8]   4D CT sorting based on patient internal anatomy [J].
Li, Ruijiang ;
Lewis, John H. ;
Cervino, Laura I. ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) :4821-4833
[9]   Issues in respiratory motion compensation during external-beam radiotherapy [J].
Ozhasoglu, C ;
Murphy, MJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05) :1389-1399
[10]   4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT [J].
Pan, T ;
Lee, TY ;
Rietzel, E ;
Chen, GTY .
MEDICAL PHYSICS, 2004, 31 (02) :333-340