An Analytical Approach to Study the Intraoperative Fractures of Femoral Shaft During Total Hip Arthroplasty

被引:7
作者
Malekmotiei, Leila [1 ]
Farahmand, Farzam [2 ]
Shodja, Hossein M. [1 ,3 ]
Samadi-Dooki, Aref [1 ]
机构
[1] Sharif Univ Technol, Dept Civil Engn, Tehran, Iran
[2] Sharif Univ Technol, Sch Mech Engn, Tehran, Iran
[3] Sharif Univ Technol, Inst Nanosci & Nanotechnol, Tehran, Iran
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2013年 / 135卷 / 04期
关键词
equivalent inclusion method; misfit strain; intraoperative fracture; hip stem; press-fit; interference; CORTICAL BONE VISCOELASTICITY; BOVINE TRABECULAR BONE; FIXATION STRENGTH; CANCELLOUS BONE; STRAIN; INCLUSION; FAILURE; FEMUR; FIT; EPIDEMIOLOGY;
D O I
10.1115/1.4023699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An analytical approach which is popular in micromechanical studies has been extended to the solution for the interference fit problem of the femoral stem in cementless total hip arthroplasty (THA). The multiple inhomogeneity problem of THA in transverse plane, including an elliptical stem, a cortical wall, and a cancellous layer interface, was formulated using the equivalent inclusion method (EIM) to obtain the induced interference elastic fields. Results indicated a maximum interference fit of about 210 mu m before bone fracture, predicted based on the Drucker-Prager criterion for a partially reamed section. The cancellous layer had a significant effect on reducing the hoop stresses in the cortical wall; the maximum press fit increased to as high as 480 mu m for a 2 mm thick cancellous. The increase of the thickness and the mechanical quality, i.e., stiffness and strength, of the cortical wall also increased the maximum interference fit before fracture significantly. No considerable effect was found for the implant material on the maximum allowable interference fit. It was concluded that while larger interference fits could be adapted for younger patients, care must be taken when dealing with the elderly and those suffering from osteoporosis. A conservative reaming procedure is beneficial for such patients; however, in order to ensure sufficient primary stability without risking bone fracture, a preoperative analysis might be necessary.
引用
收藏
页数:8
相关论文
共 49 条
  • [1] Determination of the Hounsfield value for CT-based design of custom femoral stems
    Aamodt, A
    Kvistad, KA
    Andersen, E
    Lund-Larsen, J
    Eine, J
    Benum, P
    Husby, OS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01): : 143 - 147
  • [2] Finite element modelling of primary hip stem stability: The effect of interference fit
    Abdul-Kadir, Mohammed Rafiq
    Hansen, Ulrich
    Klabunde, Ralf
    Lucas, Duncan
    Amis, Andrew
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (03) : 587 - 594
  • [3] Femoral anatomy, computed tomography and computer-aided design of prosthetic implants
    Adam, F
    Hammer, DS
    Pape, D
    Kohn, D
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (05) : 262 - 268
  • [4] Intraoperative Femur Fracture is Associated with Stem and Instrument Design in Primary Total Hip Arthroplasty
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) : 2377 - 2381
  • [5] Epidemiology - Hip and knee
    Berry, DJ
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) : 183 - +
  • [6] Prediction of strength and strain of the proximal femur by a CT-based finite element method
    Bessho, Masahiko
    Ohnishi, Isao
    Matsuyama, Juntaro
    Matsumoto, Takuya
    Imai, Kazuhiro
    Nakamura, Kozo
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (08) : 1745 - 1753
  • [7] Blaha JD., 2007, ADULT HIP, P1085
  • [8] AGING OF BONE TISSUE - MECHANICAL-PROPERTIES
    BURSTEIN, AH
    REILLY, DT
    MARTENS, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) : 82 - 86
  • [9] A Finite Element Model for Direction-Dependent Mechanical Response to Nanoindentation of Cortical Bone Allowing for Anisotropic Post-Yield Behavior of the Tissue
    Carnelli, D.
    Gastaldi, D.
    Sassi, V.
    Contro, R.
    Ortiz, C.
    Vena, P.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (08):
  • [10] Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
    Chang, WCW
    Christensen, TM
    Pinilla, TP
    Keaveny, TM
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (04) : 582 - 585