New criteria for estimating baroreflex sensitivity using the transfer function method

被引:33
作者
Pinna, GD [1 ]
Maestri, R [1 ]
机构
[1] IRCCS, Sci Inst Montescano, Clin Laboro Riabil, Dept Biomed Engn, Montescano, Italy
关键词
baroreflex sensitivity; spectral analysis; cardiovascular variability; transfer function;
D O I
10.1007/BF02347699
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Computer simulations were carried out to appraise three new criteria for the estimation of baroreflex sensitivity (BRS) using the transfer function method. The major goal was to identify a computation procedure able to overcome the intrinsic limitations of the classical coherence criterion. Four representative shapes of the gain function and three different average gains (2, 5 and 8 ms(mmHg)(-1)) in the low-frequency (LF) band (0.04-0.15 Hz) were considered. The signal-to-noise ratio was made to vary so that the peak coherence in the LF band changed from 0.15 to 0.9. All simulation parameters were derived from previous observations in healthy subjects and heart disease patients. The error of the estimated gain function was obtained from its confidence interval. BRS was computed as average gain in the LF band: (a) including in the average only those points having error less than or equal to threshold (criterion 1, C1); (b) calculating the mean error in the band and accepting BRS measurements only when this error was less than or equal to threshold (criterion 2, C2); (c) including in the average all points, regardless of the error (criterion 3, C3). The three criteria were compared in terms of measurability (percentage of measured BRS) and accuracy (bias and SD of BRS). Using C1 and C2, measurability dropped to 10% when the peak coherence in the LF band decreased, respectively, to 0.18-0.41 and to 0.26-0.53, depending on the shape and strength of the gain. In this condition (lower bound of measurability), worst bias and SD (average gain: 8 ms(mmHg)(-1)) were, respectively, 0.8 ms(mmHg)(-1) and 3.3 ms(mmHg)(-1) (C1), and 0.1 ms(mmHg)(-1) and 1.0 ms(mmHg)(-1) (C2). C3, by definition, always ensured 100% measurability and showed bias and SD comparable with, or even lower than, C1 and C2, within the common range of measurable BRS. In the extreme condition of 0.15 coherence, bias and SD were, respectively, 1.7 ms(mmHg)(-1) and 2.3 ms(mmHg)(-1) (average gain: 8 ms(mmHg)(-1)). Hence, error checking (Cl and C2) dramatically reduced measurability and did not improve accuracy of BRS measurements compared with performing no error check (C3). In conditions of low signal-to-noise ratio and/or impaired baroreflex gain, leading to markedly reduced coherence, the simple average of the gain function in the LF band allows BRS to be estimated with accuracy adequate for clinical purposes.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 13 条
[1]   CARDIOVASCULAR VARIABILITY SIGNALS - TOWARDS THE IDENTIFICATION OF A CLOSED-LOOP MODEL OF THE NEURAL CONTROL MECHANISMS [J].
BASELLI, G ;
CERUTTI, S ;
CIVARDI, S ;
MALLIANI, A ;
PAGANI, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (12) :1033-1046
[2]   The arterial baroreceptor reflex of the rat exhibits positive feedback properties at the frequency of Mayer waves [J].
Bertram, D ;
Barrès, C ;
Cuisinaud, G ;
Julien, C .
JOURNAL OF PHYSIOLOGY-LONDON, 1998, 513 (01) :251-261
[3]   HEMODYNAMIC FLUCTUATIONS AND BAROREFLEX SENSITIVITY IN HUMANS - A BEAT-TO-BEAT MODEL [J].
DEBOER, RW ;
KAREMAKER, JM ;
STRACKEE, J .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (03) :H680-H689
[4]  
La Rovere MT, 1998, LANCET, V351, P478
[5]  
Mandel J., 1991, EVALUATION CONTROL M
[6]   Depressed arterial baroreflex sensitivity and not reduced heart rate variability identifies patients with chronic heart failure and nonsustained ventricular tachycardia: The effect of high ventricular filling pressure [J].
Mortara, A ;
LaRovere, MT ;
Pinna, GD ;
Parziale, P ;
Maestri, R ;
Capomolla, S ;
Opasich, C ;
Cobelli, F ;
Tavazzi, L .
AMERICAN HEART JOURNAL, 1997, 134 (05) :879-888
[7]   Reliability of transfer function estimates in cardiovascular variability analysis [J].
Pinna, GD ;
Maestri, R .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (03) :338-347
[8]  
POLOSA C, 1984, P277
[9]  
PRIESTLEY MB, 1981, SPECTRAL ANAL TIME S, V1
[10]   Altered blood pressure variability in patients with congestive heart failure [J].
Radaelli, A ;
Perlangeli, S ;
Cerutti, MC ;
Mircoli, L ;
Mori, I ;
Boselli, L ;
Bonaita, M ;
Terzoli, L ;
Candotti, G ;
Signorini, G ;
Ferrari, AU .
JOURNAL OF HYPERTENSION, 1999, 17 (12) :1905-1910