Study on domestic sewage treatment with rotating biological contactor

被引:0
作者
Li, Fang [1 ]
Qi, Zenglu [1 ]
机构
[1] NE Petr Univ, Civil Engn Coll, Daqing 63318, Heilongjiang, Peoples R China
来源
SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4 | 2012年 / 178-181卷
关键词
RBC; removal rate of COD; HRT; domestic sewage;
D O I
10.4028/www.scientific.net/AMM.178-181.376
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper adopted a 3-stage rotating biological contactor (RBC), while the operating parameters could be controlled properly, this kind of RBC can obtain better removal effect in domestic sewage treatment. At 25 degrees C, when hydraulic retention time (HRT) is 4h,6h,8h,10h and 12h,removal rate of COD is 65.14%,86.10%,89.82%,85.93% and 78.58%.HRT fixes on 8h, removal rate of NH3 -N is 75% after adjusting alkalinity. When rotating rate of RBC is 4,6,8,10,12 and 14 r/min, the removal rate of TN is 53.88%,56.78%,60.03%,58.49%,55.32% and 54.87%.RBC also has a good removal efficiency of TP and obtains the removal rate of TP 45%. There is good prospect in domestic sewage treatment with RBC.
引用
收藏
页码:376 / 379
页数:4
相关论文
共 4 条
[1]  
*AM PUBL HLTH ASS, 1992, STAND METH EX WAT
[2]   OPTIMIZING ROTATING BIOLOGICAL CONTACTOR DISC AREA [J].
BUCHANAN, I ;
LEDUC, R .
WATER RESEARCH, 1994, 28 (08) :1851-1853
[3]  
FRIEDMAN AA, 1979, J WATER POLLUT CON F, V51, P2678
[4]   Three-dimensional eutrophication model and application to thihu lake, China [J].
Mao Jingqiao ;
Chen Qiuwen ;
Chen Yongcan .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2008, 20 (03) :278-284