PWM Strategy With Minimum Harmonic Distortion for Dual Three-Phase Permanent-Magnet Synchronous Motor Drives Operating in the Overmodulation Region

被引:123
作者
Zhou, Changpan [1 ]
Yang, Guijie [1 ]
Su, Jianyong [1 ]
机构
[1] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Harmonics suppression; multiphase machines; overmodulation; pulse width modulation (PWM); six-phase voltage source inverter (VSI); SPACE-VECTOR PWM; FIELD-ORIENTED CONTROL; CURRENT-RIPPLE RMS; INDUCTION MACHINE; CONTROL SCHEME; VSI; MODULATION; INJECTION;
D O I
10.1109/TPEL.2015.2414437
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents a novel overmodulation strategy for a six-phase voltage source inverter (VSI)-fed dual three-phase permanent-magnet synchronous motor. The proposed strategy can achieve minimum harmonic injection in the overmodulation region. Four-vector space vector pulse width modulation (SVPWM) renders mathematic foundations for this given method. However, the classical four-vector SVPWM used in six-phase VSI has asymmetrical pulse width modulation waveform, which makes it difficult for hardware implementation. In this paper, the modulation algorithms in both linear and overmodulation regions have been unified and implemented with the double zero-sequence injection PWM strategy. This strategy is able to overcome the inherent shortcomings of the four-vector SVPWM, and it achieves smooth transitions from linear to overmodulation region. Simulation analysis and experimental results demonstrate the effectiveness and feasibility of the proposed strategy.
引用
收藏
页码:1367 / 1380
页数:14
相关论文
共 31 条
[1]   Analysis of a hybrid PWM based on modified space-vector and triangle-comparison methods [J].
Blasko, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :756-764
[2]   Dual three-phase induction motor drive with digital current control in the stationary reference frame [J].
Bojoi, R ;
Levi, E ;
Farina, F ;
Tenconi, A ;
Profumo, F .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (01) :129-139
[3]  
Bojoi R, 2003, IEEE POWER ELECTRON, P1475
[4]  
Bojoi R, 2002, IEEE POWER ELECTRON, P851, DOI 10.1109/PSEC.2002.1022560
[5]   Digital field-oriented control for dual three-phase induction motor drives [J].
Bojoi, R ;
Lazzari, M ;
Profumo, F ;
Tenconi, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (03) :752-760
[6]   Space Vector PWM Method for Five-Phase Two-Level VSI With Minimum Harmonic Injection in the Overmodulation Region [J].
Carrasco, Gonzalo ;
Silva, Cesar A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (05) :2042-2053
[7]   Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points [J].
Che, Hang Seng ;
Duran, Mario J. ;
Levi, Emil ;
Jones, Martin ;
Hew, Wooi-Ping ;
Abd Rahim, Nasrudin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (10) :5406-5416
[8]   Current Control Methods for an Asymmetrical Six-Phase Induction Motor Drive [J].
Che, Hang Seng ;
Levi, Emil ;
Jones, Martin ;
Hew, Wooi-Ping ;
Abd Rahim, Nasrudin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (01) :407-417
[9]   Analysis of Output Current-Ripple RMS in Multiphase Drives Using Polygon Approach [J].
Dujic, Drazen ;
Jones, Martin ;
Levi, Emil .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (07) :1838-1849
[10]   Analysis of Output Current Ripple rms in Multiphase Drives Using Space Vector Approach [J].
Dujic, Drazen ;
Jones, Martin ;
Levi, Emil .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :1926-1938