Comparative Assessment of DNA Extraction Techniques From Formalin-Fixed, Paraffin-Embedded Tumor Specimens and Their Impact on Downstream Analysis

被引:4
作者
Bapat, Prachi R. [1 ]
Epari, Sridhar [1 ]
Joshi, Pradnya, V [1 ]
Dhanavade, Dipika S. [1 ]
Rumde, Rachna H. [1 ]
Gurav, Mamta Y. [1 ]
Shetty, Omshree A. [1 ]
Desai, Sangeeta B. [1 ]
机构
[1] Homi Bhabha Natl Inst, Tata Mem Hosp, Mol Pathol, Mumbai, Maharashtra, India
关键词
FFPE tissues; DNA extraction techniques; Nucleic acid quality; PCR; Sequencing; TISSUES; SAMPLES;
D O I
10.1093/ajcp/aqac122
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objectives Good-quality nucleic acid extraction from formalin-fixed, paraffin-embedded (FFPE) specimens remains a challenge in molecular-oncopathology practice. This study evaluates the efficacy of an in-house developed FFPE extraction buffer compared with other commercially available kits. Methods Eighty FFPE specimens processed in different surgical pathology laboratories formed the study sample. DNA extraction was performed using three commercial kits and the in-house developed FFPE extraction buffer. DNA yield was quantified by a NanoDrop spectrophotometer and Qubit Fluorometer, and its purity was measured by the 260/280-nm ratio. A fragment analyzer system was used for accurate sizing of DNA fragments of FFPE DNA. The downstream effects of all extraction methods were evaluated by polymerase chain reaction (PCR) and Sanger sequencing. Results In comparison with the commercial kits, the in-house buffer yielded higher DNA quantity and quality number (P < .0001). In addition, DNA integrity and fragment size were preserved in a significantly greater number of samples isolated with the in-house buffer (P < .05). The target PCR amplification rate with the in-house buffer extracted samples was also significantly higher, with 98% of the samples showing interpretable sequencing results. Conclusions The in-house developed FFPE extraction buffer performed superior to other methods in terms of suitability for downstream applications, time, cost-efficiency, and ease of performance.
引用
收藏
页码:739 / 749
页数:11
相关论文
共 15 条
  • [1] Atanesyan L, 2017, AM J CLIN PATHOL, V147, P60, DOI [10.1093/AJCP/AQW205, 10.1093/ajcp/aqw205]
  • [2] What interventions are required to reduce road traffic injuries in Africa? A scoping review of the literature
    Bonnet, Emmanuel
    Lechat, Lucie
    Ridde, Valery
    [J]. PLOS ONE, 2018, 13 (11):
  • [3] Preanalytics and Precision Pathology Pathology Practices to Ensure Molecular Integrity of Cancer Patient Biospecimens for Precision Medicine
    Compton, Carolyn C.
    Robb, James A.
    Anderson, Matthew W.
    Berry, Anna B.
    Birdsong, George G.
    Bloom, Kenneth J.
    Branton, Philip A.
    Crothers, Jessica W.
    Cushman-Vokoun, Allison M.
    Hicks, David G.
    Khoury, Joseph D.
    Laser, Jordan
    Marshall, Carrie B.
    Misialek, Michael J.
    Natale, Kristen E.
    Nowak, Jan Anthony
    Olson, Damon
    Pfeifer, John D.
    Schade, Andrew
    Vance, Gail H.
    Walk, Eric E.
    Yohe, Sophia Louise
    [J]. ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2019, 143 (11) : 1346 - 1363
  • [4] Factors that drive the increasing use of FFPE tissue in basic and translational cancer research
    Gaffney, E. F.
    Riegman, P. H.
    Grizzle, W. E.
    Watson, P. H.
    [J]. BIOTECHNIC & HISTOCHEMISTRY, 2018, 93 (05) : 373 - 386
  • [5] Comparison of Two Methods to Extract DNA from Formalin-Fixed, Paraffin-Embedded Tissues and their Impact on EGFR Mutation Detection in Non-small Cell Lung Carcinoma
    Hu, Yu-Chang
    Zhang, Qian
    Huang, Yan-Hua
    Liu, Yu-Fei
    Chen, Hong-Lei
    [J]. ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (06) : 2733 - 2737
  • [6] Comparative analysis of four methods to extract DNA from paraffin-embedded tissues: Effect on downstream molecular applications
    Huijsmans C.J.J.
    Damen J.
    Van Der Linden J.C.
    Savelkoul P.H.M.
    Hermans M.H.A.
    [J]. BMC Research Notes, 3 (1)
  • [7] Comparison of eight commercially available kits for DNA extraction from formalin-fixed paraffin-embedded tissues
    Janecka, Anna
    Adamczyk, Agnieszka
    Gasinska, Anna
    [J]. ANALYTICAL BIOCHEMISTRY, 2015, 476 : 8 - 10
  • [8] Archived Formalin-Fixed Paraffin-Embedded (FFPE) Blocks: A Valuable Underexploited Resource for Extraction of DNA, RNA, and Protein
    Kokkat, Theresa J.
    Patel, Miral S.
    McGarvey, Diane
    LiVolsi, Virginia A.
    Baloch, Zubair W.
    [J]. BIOPRESERVATION AND BIOBANKING, 2013, 11 (02) : 101 - 106
  • [9] DNA extraction from paraffin embedded colorectal carcinoma samples: A comparison study of manual vs automated methods, using four commercially kits
    Kovacs, Zsolt
    Jung, Ioan
    Csernak, Erzsebet
    Szentirmay, Zoltan
    Banias, Laura
    Rigmanyi, Genoveva
    Gurzu, Simona
    [J]. WORLD JOURNAL OF CLINICAL ONCOLOGY, 2019, 10 (09): : 307 - 317
  • [10] Use of FFPE-derived DNA in next generation sequencing: DNA extraction methods
    McDonough, Samantha J.
    Bhagwate, Aditya
    Sun, Zhifu
    Wang, Chen
    Zschunke, Michael
    Gorman, Joshua A.
    Kopp, Karla J.
    Cunningham, Julie M.
    [J]. PLOS ONE, 2019, 14 (04):