Expanding the Operational Limits of the Single-Point Impedance Diagnostic for Internal Temperature Monitoring of Lithium-ion Batteries

被引:77
作者
Spinner, Neil S. [1 ,2 ]
Love, Corey T. [1 ]
Rose-Pehrsson, Susan L. [1 ]
Tuttle, Steven G. [1 ]
机构
[1] US Naval Res Lab, Div Chem, Washington, DC 20375 USA
[2] Natl Acad Sci, Natl Res Council, Washington, DC 20001 USA
关键词
Electrochemical Impedance Spectroscopy; Lithium-Ion; Temperature Diagnostic; LI-ION; ELECTROCHEMICAL IMPEDANCE; LITHIATED GRAPHITE; THERMAL-BEHAVIOR; SHORT-CIRCUIT; CELLS; SPECTROSCOPY; OVERCHARGE; MECHANISMS; ELECTRODES;
D O I
10.1016/j.electacta.2015.06.003
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Instantaneous internal temperature monitoring of a commercial 18650 LiCoO2 lithium-ion battery was performed using a single-point EIS measurement. A correlation between the imaginary impedance, -Z(imag), and internal temperature at 300 Hz was developed that was independent of the battery's state of charge. An Arrhenius-type dependence was applied, and the activation energy for SEI ionic conductivity was found to be 0.13 eV. Two separate temperature-time experiments were conducted with different sequences of temperature, and single-point impedance tests at 300 Hz were performed to validate the correlation. Limitations were observed with the upper temperature range (68 degrees C < T< 95 degrees C), and consequently a secondary, empirical fit was applied for this upper range to improve accuracy. Average differences between actual and fit temperatures decreased around 3-7 degrees C for the upper range with the secondary correlation. The impedance response at this frequency corresponded to the anode/SEI layer, and the SEI is reported to be thermally stable up to around 100 degrees C, at which point decomposition may occur leading to battery deactivation and/or total failure. It is therefore of great importance to be able to track internal battery temperatures up to this critical point of 100 degrees C, and this work demonstrates an expansion of the single-point EIS diagnostic to these elevated temperatures. Published by Elsevier Ltd.
引用
收藏
页码:488 / 493
页数:6
相关论文
共 46 条
  • [41] Data-Driven-Based Internal Temperature Estimation for Lithium-Ion Battery Under Variant State-of-Charge via Electrochemical Impedance Spectroscopy
    Ouyang, Konglei
    Fan, Yuqian
    Yazdi, Mohammad
    Peng, Weiwen
    ENERGY TECHNOLOGY, 2022, 10 (03)
  • [42] An optimal internal-heating strategy for lithium-ion batteries at low temperature considering both heating time and lifetime reduction
    Ruan, Haijun
    Jiang, Jiuchun
    Sun, Bingxiang
    Su, Xiaojia
    He, Xitian
    Zhao, Kejie
    APPLIED ENERGY, 2019, 256
  • [43] Detection of Unbalanced Voltage Cells in Series-connected Lithium-ion Batteries Using Single-frequency Electrochemical Impedance Spectroscopy
    Togasaki, Norihiro
    Yokoshima, Tokihiko
    Oguma, Yasumasa
    Osaka, Tetsuya
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2021, 12 (04) : 415 - 423
  • [44] Operando monitoring of internal gas pressure in commercial lithium-ion batteries via a MEMS-assisted fiber-optic interferometer
    Tan, Ke
    Li, Wei
    Lin, Zhen
    Han, Xile
    Dai, Xiaoshuang
    Li, Shikai
    Liu, Zhi
    Liu, Hongyu
    Sun, Long
    Jiang, Junfeng
    Liu, Tiegen
    Wu, Kai
    Guo, Tuan
    Wang, Shuang
    JOURNAL OF POWER SOURCES, 2023, 580
  • [45] On-board monitoring of 2-D spatially-resolved temperatures in cylindrical lithium-ion batteries: Part II. State estimation via impedance-based temperature sensing
    Richardson, Robert R.
    Zhao, Shi
    Howey, David A.
    JOURNAL OF POWER SOURCES, 2016, 327 : 726 - 735
  • [46] Decoupling parameter estimation strategy based electrochemical-thermal coupled modeling method for large format lithium-ion batteries with internal temperature experimental validation
    Wang, Qian-Kun
    Shen, Jia-Ni
    Ma, Zi-Feng
    He, Yi-Jun
    CHEMICAL ENGINEERING JOURNAL, 2021, 424 (424)