The effect of posterior cruciate ligament reconstruction on patellofemoral contact pressures in the knee joint under simulated muscle loads

被引:69
作者
Gill, TJ
DeFrate, LE
Wang, C
Carey, CT
Zayontz, S
Zarins, B
Li, G
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Orthopaed Biomech Lab, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Boston, MA 02115 USA
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
posterior cruciate ligament; patellofemoral joint; contact pressures; ligament reconstruction; knee biomechanics;
D O I
10.1177/0095399703258794
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The mechanism of cartilage degeneration in the patellofemoral joint (PFJ) and medial compartment of the knee following posterior cruciate ligament (PCL) injury remains unclear. PCL reconstruction has been recommended to restore kinematics and prevent long-term degeneration. The effect of current reconstruction techniques on PFJ contact pressures is unknown. Purpose: To measure PFJ contact pressures after PCL deficiency and reconstruction. Method: Eight cadaveric knees were tested with the PCL intact, deficient, and reconstructed. Contact pressures were measured at 30degrees, 60degrees, 90degrees, and 120degrees of flexion under simulated muscle loads. Knee kinematics were measured by a robotic testing. system, and the PFJ contact pressures were measured using a thin film transducer. A single bundle achilles tendon allograft was used in the reconstruction. Results: PCL deficiency significantly increased the peak contact pressures measured in the PFJ relative to the intact knee under both an isolated quadriceps load of 400 N and a combined quadriceps/hamstrings load of 400 N/200 N. Reconstruction did not significantly reduce the increased contact pressures observed in the PCL-deficient knee. Conclusion: The elevated contact pressures observed in the PCL-deficient knee and reconstructed knee might contribute to the long-term degeneration observed in both the non-operatively treated and PCL-reconstructed knees.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 45 条
[1]   A biomechanical comparison of posterior cruciate ligament reconstruction techniques [J].
Bergfeld, JA ;
McAllister, DR ;
Parker, RD ;
Valdevit, ADC ;
Kambic, HE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) :129-136
[2]   Long-term followup of the untreated isolated posterior cruciate ligament-deficient knee [J].
Boynton, MD ;
Tietjens, BR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (03) :306-310
[3]   Athletics and osteoarthritis [J].
Buckwalter, JA ;
Lane, NE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (06) :873-881
[4]   THE EFFECT OF FEMORAL TUNNEL POSITION AND GRAFT TENSIONING TECHNIQUE ON POSTERIOR LAXITY OF THE POSTERIOR CRUCIATE LIGAMENT-RECONSTRUCTED KNEE [J].
BURNS, WC ;
DRAGANICH, LF ;
PYEVICH, M ;
REIDER, B .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (04) :424-430
[5]   LIGAMENTOUS RESTRAINTS TO ANTERIOR-POSTERIOR DRAWER IN THE HUMAN KNEE - BIOMECHANICAL STUDY [J].
BUTLER, DL ;
NOYES, FR ;
GROOD, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02) :259-270
[6]   PERFORMANCE OF AN ATHLETE WITH STRAIGHT POSTERIOR KNEE INSTABILITY [J].
CAIN, TE ;
SCHWAB, GH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1981, 9 (04) :203-208
[7]  
CASTLE TH, 1992, CLIN ORTHOP RELAT R, P193
[8]   TREATMENT OF KNEE-JOINT INSTABILITY SECONDARY TO RUPTURE OF THE POSTERIOR CRUCIATE LIGAMENT - REPORT OF A NEW PROCEDURE [J].
CLANCY, WG ;
SHELBOURNE, KD ;
ZOELLNER, GB ;
KEENE, JS ;
REIDER, B ;
ROSENBERG, TD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (03) :310-322
[9]   LONG-TERM FOLLOW-UP OF POSTERIOR CRUCIATE LIGAMENT RUPTURE - A STUDY OF 116 CASES [J].
CROSS, MJ ;
POWELL, JF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1984, 12 (04) :292-297
[10]   AN INVITRO ANALYSIS OF PATELLOFEMORAL CONTACT AREAS AND PRESSURES FOLLOWING PROCUREMENT OF THE CENTRAL 1/3 PATELLAR TENDON [J].
DAGATA, SD ;
PEARSALL, AW ;
REIDER, B ;
DRAGANICH, LF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (02) :212-219