Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws

被引:19
|
作者
Zipprich, Holger [1 ]
Rathe, Florian [2 ]
Pinz, Soeren [3 ]
Schlotmann, Luca [3 ]
Lauer, Hans-Christoph [3 ]
Ratka, Christoph [3 ]
机构
[1] Goethe Univ Frankfurt, Dept Prosthodont, Mat Sci Unit, Frankfurt, Germany
[2] DANUBE Private Univ, Dept Prosthodont, Krems An Der Donau, Austria
[3] Goethe Univ Frankfurt, Dept Prosthodont, Theodor Stern Kai 7,House 29, DE-60596 Frankfurt, Germany
关键词
abutment; abutment screw; abutment screw configuration; dental implant; preload force; thread pitch; FINITE-ELEMENT-ANALYSIS; BONE;
D O I
10.11607/jomi.5837
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. Materials and Methods: The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Results: Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. Conclusion: The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.
引用
收藏
页码:E25 / E32
页数:8
相关论文
共 50 条
  • [41] Effects of Repeated Manual Disassembly and Reassembly on the Positional Stability of Various Implant-Abutment Complexes: An Experimental Study
    Semper, Wiebke
    Heberer, Susanne
    Mehrhof, Juergen
    Schink, Tania
    Nelson, Katja
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (01) : 86 - 94
  • [42] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Disayut Klongbunjit
    Weerapan Aunmeungtong
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 7
  • [43] Analysis of Implant Strength After Implantoplasty in Three Implant-Abutment Connection Designs: An In Vitro Study
    Alexandre Gehrke, Sergio
    Aramburu Junior, Jaime Sarda
    Dedavid, Berenice Anina
    Shibli, Jamil Awad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : E65 - E70
  • [44] Influence of Implant-Abutment Contact Surfaces and Prosthetic Screw Tightening on the Stress Concentration, Fatigue Life and Microgap Formation: A Finite Element Analysis
    Tribst, Joao Paulo Mendes
    Dal Piva, Amanda Maria de Oliveira
    da Silva-Concilio, Lais Regiane
    Ausiello, Pietro
    Kalman, Les
    ORAL, 2021, 1 (02): : 88 - 101
  • [45] Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments
    AlAmar, Mohammed
    Alqahtani, Fawaz
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (02) : 88 - 92
  • [46] Assessment of Leakage at the Implant-Abutment Connection Using a New Gas Flow Method
    Fauroux, Marie-Alix
    Levallois, Bernard
    Yachouh, Jacques
    Torres, Jacques-Henri
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (06) : 1409 - 1412
  • [47] Effect of the implant-abutment interface on peri-implant tissues: A systematic review
    Bishti, Shaza
    Strub, Joerg R.
    Att, Wael
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (01) : 13 - 25
  • [48] The Effects of Simulated Bone Loss on the Implant-Abutment Assembly and Likelihood of Fracture: An In Vitro Study
    Manzoor, Behzad
    Suleiman, Mahmood
    Palmer, Richard M.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 729 - 738
  • [49] Effects of different implant-abutment connections on micromotion and stress distribution: Prediction of microgap formation
    Saidin, Syafiqah
    Kadir, Mohammed Rafiq Abdul
    Sulaiman, Eshamsul
    Abu Kasim, Noor Hayaty
    JOURNAL OF DENTISTRY, 2012, 40 (06) : 467 - 474
  • [50] Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    Kitagawa, T
    Tanimoto, Y
    Odaki, M
    Nemoto, K
    Aida, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 457 - 463