Stereotactic Vacuum-Assisted Biopsies on a Digital Breast 3D-Tomosynthesis System

被引:38
|
作者
Viala, Juliette [1 ]
Gignier, Pierre [1 ]
Perret, Baudouin [1 ]
Hovasse, Claudie [1 ]
Hovasse, Denis [1 ]
Chancelier-Galan, Marie-Dominique [1 ]
Bornet, Gregoire [1 ]
Hamrouni, Adel [1 ]
Lasry, Jean-Louis [1 ]
Convard, Jean-Paul [1 ]
机构
[1] Hop Prive Antony, Dept Radiol, F-92160 Antony, France
来源
BREAST JOURNAL | 2013年 / 19卷 / 01期
关键词
breast biopsy; digital breast tomosynthesis; TOMOSYNTHESIS; MAMMOGRAPHY;
D O I
10.1111/tbj.12044
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to describe our operating process and to report results of 118 stereotactic vacuum-assisted biopsies performed on a digital breast 3D-tomosynthesis system. From October 2009 to December 2010, 118 stereotactic vacuum assisted biopsies have been performed on a digital breast 3D-tomosynthesis system. Informed consent was obtained for all patients. A total of 106 patients had a lesion, six had two lesions. Sixty-one lesions were clusters of micro-calcifications, 54 were masses and three were architectural distortions. Patients were in lateral decubitus position to allow shortest skin-target approach (or sitting). Specific compression paddle, adapted on the system, performed, and graduated, allowing localization in X-Y. Tomosynthesis views define the depth of lesion. Graduated Coaxial localization kit determines the beginning of the biopsy window. Biopsies were performed with an ATEC-Suros, 9 Gauge handpiece. All biopsies, except one, have reached the lesions. Five hemorrhages were incurred in the process, but no interruption was needed. Eight breast hematomas, were all spontaneously resolved. One was an infection. About 40% of patients had a skin ecchymosis. Processing is fast, easy, and requires lower irradiation dose than with classical stereotactic biopsies. Histology analysis reported 45 benign clusters of micro-calcifications, 16 malignant clusters of micro-calcifications, 24 benign masses, and 33 malignant masses. Of 13 malignant lesions, digital 2D-mammography failed to detect eight lesions and underestimated the classification of five lesions. Digital breast 3D-tomosynthesis depicts malignant lesions not visualized on digital 2D-mammography. Development of tomosynthesis biopsy unit integrated to stereotactic system will permit histology analysis for suspicious lesions.
引用
收藏
页码:4 / 9
页数:6
相关论文
共 50 条
  • [41] B3 breast lesions determined by vacuum-assisted biopsy: how to reduce the frequency of benign excision biopsies
    Tonegutti, M.
    Girardi, V.
    Ciatto, S.
    Manfrin, E.
    Bonetti, F.
    RADIOLOGIA MEDICA, 2010, 115 (08): : 1246 - 1257
  • [42] Clinical analysis of stereotactic or ultrasound-guided vacuum-assisted breast biopsy in the diagnosis of breast micro calcifications
    Guo, Jing
    Sun, Min
    Li, Shuofeng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (04): : 3893 - 3898
  • [43] Vacuum-assisted biopsy system for breast lesions: a potential therapeutic approach
    Zhu, Yue
    Chen, Xingyan
    Dou, He
    Liu, Yuqi
    Li, Fucheng
    Wang, Youyu
    Xiao, Min
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [44] Frequency of Discordant Lesions and False-negative Cancers at Stereotactic Vacuum-assisted Biopsy
    Heller, Samantha L.
    Jaglan, Sonam
    Babb, James S.
    Melsaether, Amy
    Toth, Hildegard B.
    Moy, Linda
    ACADEMIC RADIOLOGY, 2016, 23 (08) : 994 - 999
  • [45] Vacuum-assisted biopsies under MR guidance: results of 72 procedures
    Malhaire, C.
    El Khoury, C.
    Thibault, F.
    Athanasiou, A.
    Petrow, P.
    Ollivier, L.
    Tardivon, A.
    EUROPEAN RADIOLOGY, 2010, 20 (07) : 1554 - 1562
  • [46] Vacuum-assisted breast biopsy: comparison of three systems
    Canavan, F.
    Wilson, A. R.
    Michell, M. J.
    Evans, D.
    Peacock, C.
    Wasan, R.
    O'Grady, A.
    BREAST CANCER RESEARCH, 2008, 10
  • [47] Vacuum-assisted breast biopsy: comparison of three systems
    F Canavan
    AR Wilson
    MJ Michell
    D Evans
    C Peacock
    R Wasan
    A O'Grady
    Breast Cancer Research, 10
  • [48] Digital breast tomosynthesis (3D-mammography) for screening women with dense breasts
    Houssami, Nehmat
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (06) : 515 - 517
  • [49] Discrepancies between radiological and histological findings in preoperative core needle (CNB) and vacuum-assisted (VAB) breast biopsies
    Jorg, Inna
    Wieler, Jann
    Elfgen, Constanze
    Bolten, Kristina
    Hutzli, Claudia
    Talimi, Julia
    Vorburger, Denise
    Choschzick, Matthias
    Moskovszky, Linda
    Dedes, Konstantin
    Varga, Zsuzsanna
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2021, 147 (03) : 749 - 754
  • [50] Outcome Analysis of 9-Gauge MRI-Guided Vacuum-Assisted Core Needle Breast Biopsies
    Rauch, Gaiane M.
    Dogan, Basak E.
    Smith, Taletha B.
    Liu, Ping
    Yang, Wei T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : 292 - 299