Stereotactic Vacuum-Assisted Biopsies on a Digital Breast 3D-Tomosynthesis System

被引:38
|
作者
Viala, Juliette [1 ]
Gignier, Pierre [1 ]
Perret, Baudouin [1 ]
Hovasse, Claudie [1 ]
Hovasse, Denis [1 ]
Chancelier-Galan, Marie-Dominique [1 ]
Bornet, Gregoire [1 ]
Hamrouni, Adel [1 ]
Lasry, Jean-Louis [1 ]
Convard, Jean-Paul [1 ]
机构
[1] Hop Prive Antony, Dept Radiol, F-92160 Antony, France
来源
BREAST JOURNAL | 2013年 / 19卷 / 01期
关键词
breast biopsy; digital breast tomosynthesis; TOMOSYNTHESIS; MAMMOGRAPHY;
D O I
10.1111/tbj.12044
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to describe our operating process and to report results of 118 stereotactic vacuum-assisted biopsies performed on a digital breast 3D-tomosynthesis system. From October 2009 to December 2010, 118 stereotactic vacuum assisted biopsies have been performed on a digital breast 3D-tomosynthesis system. Informed consent was obtained for all patients. A total of 106 patients had a lesion, six had two lesions. Sixty-one lesions were clusters of micro-calcifications, 54 were masses and three were architectural distortions. Patients were in lateral decubitus position to allow shortest skin-target approach (or sitting). Specific compression paddle, adapted on the system, performed, and graduated, allowing localization in X-Y. Tomosynthesis views define the depth of lesion. Graduated Coaxial localization kit determines the beginning of the biopsy window. Biopsies were performed with an ATEC-Suros, 9 Gauge handpiece. All biopsies, except one, have reached the lesions. Five hemorrhages were incurred in the process, but no interruption was needed. Eight breast hematomas, were all spontaneously resolved. One was an infection. About 40% of patients had a skin ecchymosis. Processing is fast, easy, and requires lower irradiation dose than with classical stereotactic biopsies. Histology analysis reported 45 benign clusters of micro-calcifications, 16 malignant clusters of micro-calcifications, 24 benign masses, and 33 malignant masses. Of 13 malignant lesions, digital 2D-mammography failed to detect eight lesions and underestimated the classification of five lesions. Digital breast 3D-tomosynthesis depicts malignant lesions not visualized on digital 2D-mammography. Development of tomosynthesis biopsy unit integrated to stereotactic system will permit histology analysis for suspicious lesions.
引用
收藏
页码:4 / 9
页数:6
相关论文
共 50 条
  • [1] Guiding vacuum-assisted biopsy in prone position: digital breast tomosynthesis vs stereotactic
    Scaperrotta, Gianfranco P.
    Boffelli, Giulia
    Depretto, Catherine
    Di Leo, Giovanni
    Liguori, Alessandro
    Monaco, Cristian Giuseppe
    Anna, Borelli
    Ferranti, Claudio
    TUMORI JOURNAL, 2022, 108 (04): : 326 - 330
  • [2] Digital Breast Tomosynthesis-guided Vacuum-assisted Breast Biopsy: Initial Experiences and Comparison with Prone Stereotactic Vacuum-assisted Biopsy
    Schrading, Simone
    Distelmaier, Martina
    Dirrichs, Timm
    Detering, Sabine
    Brolund, Liv
    Strobel, Kevin
    Kuhl, Christiane K.
    RADIOLOGY, 2015, 274 (03) : 654 - 662
  • [3] Comparison of Upright Digital Breast Tomosynthesis-guided versus Prone Stereotactic Vacuum-assisted Breast Biopsy
    Bahl, Manisha
    Maunglay, Mary
    D'Alessaneiro, Helen Anne
    Lehman, Constance D.
    RADIOLOGY, 2019, 290 (02) : 298 - 304
  • [4] Tomosynthesis-guided vacuum-assisted breast biopsy: A feasibility study
    Waldherr, Christian
    Berclaz, Gilles
    Altermatt, Hans Jorg
    Cerny, Peter
    Keller, Patrik
    Dietz, Uwe
    Buser, Katharina
    Ciriolo, Michele
    Sonnenschein, Martin Josef
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1582 - 1589
  • [5] Tomosynthesis-guided vacuum-assisted breast biopsy: A feasibility study
    Christian Waldherr
    Gilles Berclaz
    Hans Jörg Altermatt
    Peter Cerny
    Patrik Keller
    Uwe Dietz
    Katharina Buser
    Michele Ciriolo
    Martin Josef Sonnenschein
    European Radiology, 2016, 26 : 1582 - 1589
  • [6] Transition to digital breast tomosynthesis-guided biopsies: Results and complications compared to stereotactic biopsies
    Weinfurtner, R. Jared
    Carter, Travis
    BREAST JOURNAL, 2021, 27 (01): : 21 - 26
  • [7] Comparison of radiation dose between 2D digital stereotactic versus digital breast tomosynthesis-guided breast biopsies
    Amir, T.
    Zuckerman, S. P.
    Barufaldi, B.
    Maidment, A. D.
    Conant, E. F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [8] Radiomic Applications on Digital Breast Tomosynthesis of BI-RADS Category 4 Calcifications Sent for Vacuum-Assisted Breast Biopsy
    Favati, Benedetta
    Borgheresi, Rita
    Giannelli, Marco
    Marini, Carolina
    Vani, Vanina
    Marfisi, Daniela
    Linsalata, Stefania
    Moretti, Monica
    Mazzotta, Dionisia
    Neri, Emanuele
    DIAGNOSTICS, 2022, 12 (04)
  • [9] Percutaneous vacuum-assisted core breast biopsy with upright stereotactic equipment
    Meloni, GB
    Becchere, MP
    Soro, D
    Feo, CF
    Profili, S
    Dettori, G
    Trignano, M
    Navarra, G
    Canalis, GC
    ACTA RADIOLOGICA, 2002, 43 (06) : 575 - 578
  • [10] Evaluation of mammographic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies
    Rotter, K
    Haentschel, G
    Koethe, D
    Goetz, L
    Bornhofen-Pöschke, A
    Lebrecht, A
    Kölbl, H
    Heywang-Koebrunner, S
    AMERICAN JOURNAL OF SURGERY, 2003, 186 (02): : 134 - 142