Experimental and simulation studies on air source heat pump water heater for year-round applications in Canada

被引:35
|
作者
Amirirad, Afarin [1 ]
Kumar, Rakesh [1 ]
Fung, Alan S. [1 ]
Leong, Wey H. [1 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, 350 Victoria St, Toronto, ON M5B 2K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Air source heat pump water heater; Sustainable house; Experimental data; Coefficient of performance; TRNSYS simulation; Energy saving; PERFORMANCE; SYSTEM;
D O I
10.1016/j.enbuild.2018.01.052
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of a new type of Air Source Heat Pump Water Heater (ASHPWH) has been investigated. ASHPWH has a better performance than the conventional electric water heater if it is installed in a hotter climate. However, the conditions are different in Canada, where outside air temperature is well below the freezing point for several months, and that diminishes the water heating capacity of these systems significantly. On the other hand, if it is installed in the indoor space (which is the case of this research), the presence of the system in the house affects the house heating and cooling loads. Therefore, an understanding of energy performance of this types water heaters is critical to justify their use in the Canadian houses. The research methodology involved, installation of the ASHPWH unit in an Archetype Sustainable House (ASH), reconfiguration of some parts of house plumbing system, build sensors and data acquisition system to collect real-time experimental data, developed and validated TRNSYS models. Furthermore, the validated models were applied to evaluate the performance of the unit to meet the year-round hot water demand and established its significance with respect to the conventional electric water heater. It was concluded that the temperature and humidity of surrounding air produced a considerable impact on the heating capacity of the ASHPWH. The best coefficient of performance (COP) was obtained at 20 degrees C and 35% RH from the chosen sets of air conditions. The outlet water temperature fluctuates in the range of 49.5 degrees C to 55.9 degrees C (while the setpoint temperature was taken at 54 degrees C). The system will increase the combined space heating and cooling electricity consumptions annually by 3%, on the other hand, a reduction of 55% of water heater related annual electricity consumption was noted relative to the conventional electric water heater. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [41] Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump
    Yu, X.
    Wang, R. Z.
    Zhai, X. Q.
    ENERGY, 2011, 36 (02) : 1309 - 1318
  • [42] Experimental analysis of an air-source transcritical CO2 heat pump water heater using the hot gas bypass defrosting method
    Hu, Bin
    Wang, Xiaolin
    Cao, Feng
    He, Zhilong
    Xing, Ziwen
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 528 - 535
  • [43] Analysis and optimization on the performance of a heat pump water heater with solar-air dual series source
    Cai, Jingyong
    Zhou, Haihua
    Shi, Zhengrong
    Chen, Haifei
    Zhang, Tao
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [44] Research on Using Mixed Refrigerant to Replace the Traditional Refrigerant in Air Source Heat Pump Water Heater
    Yu, Chen
    Wang, Fang
    Wu, Xin
    Ding, Jing-hua
    Si-na, A.
    Hua, Wang
    Liu, Jin-jin
    3RD INTERNATIONAL CONFERENCE ON GREEN MATERIALS AND ENVIRONMENTAL ENGINEERING (GMEE), 2017, : 235 - 239
  • [45] Research on Using Mixed Refrigerant to Replace the Traditional Refrigerant in Air Source Heat Pump Water Heater
    Yu, Cheng
    Wang, Fang
    Fang, Hai-Xiang
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2017), 2017, 143 : 339 - 343
  • [46] Experimental investigation of an air source heat pump with multigroup heat pipe radiators
    Xu, Shuxue
    Niu, Jianhui
    Ma, Guoyuan
    SOLAR ENERGY, 2023, 260 : 137 - 146
  • [47] Experimental and theoretical study on an air-source heat pump water heater for northern China in cold winter: Effects of environment temperature and switch of operating modes
    Xu, Yingjie
    Huang, Yuangong
    Jiang, Ning
    Song, Mengjie
    Xie, Xiaodong
    Xu, Xiaoxiao
    ENERGY AND BUILDINGS, 2019, 191 : 164 - 173
  • [48] Extremum seeking control for efficient operation of an air-source heat pump water heater with internal heat exchanger cycle vapor injection
    Wang, Wenyi
    Li, Yaoyu
    Cao, Feng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 153 - 165
  • [49] Hybrid ground source heat pump system capable of year-round heating and its application in liquid natural gas vaporization
    Katsura, Takao
    Shoji, Yutaka
    Yang, Kunning
    Akai, Hitoshi
    Shishido, Jun
    Ishikawa, Mitsuhiro
    Yashima, Yuichi
    Tanifuji, Koji
    Nagano, Katsunori
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (15) : 23388 - 23406
  • [50] STUDY ON QUASI TWO-STAGE COMPRESSION CYCLE CHARACTERISTICS OF THE WATER HEATER OF THE AIR SOURCE HEAT PUMP IN COLD AREA
    LI, Haijun
    Su, Zhiyong
    Niu, Huawei
    Zhai, Junjie
    Kou, Jingkang
    Wang, Fang
    Cai, Xia
    Zhang, Qingge
    Wang, Shihao
    THERMAL SCIENCE, 2022, 26 (3B): : 2645 - 2651